• 제목/요약/키워드: Distance between buildings

검색결과 134건 처리시간 0.025초

APPLICATION OF WIRELESS INCLINOMETER FOR DISPLACEMENT MEASUREMENT OF TEMPORARY EARTH RETAINING PILE

  • Chi Hun In;Hong Chul Rhim
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.218-223
    • /
    • 2009
  • During the process of excavation for substructures of buildings, precise and constant measurements of retaining wall displacement is crucial for construction to be complete and safe. Currently an inclinometer is used to measure displacement around the perimeter of an excavation site. The existing inclinometer system requires an instrument to be placed inside pre-bored holes for each measurement with an typical interval of two weeks. This makes it difficult to obtain continuous displacement data, especially during a critical time such as rainy season in summer. Also, the existing inclinometer is placed at certain distance away from the retaining wall system itself. Thus, exact measurement of retaining wall movement is compromised because of the distance between the retaining wall and the inclinometer. This paper presents the development of wireless inclinometer system for the displacement measurement of retaining walls by being attached directly to the retaining wall. The result of the application of the developed systems are provided with advanced ubiquitous sensor network (USN) system features. The USN technique incorporated into the system enables users to monitor movement data from wherever possible and convenient such as construction manager's office on site or any other places connected through internet. The research work presented in this paper will provide a basis to save construction time and cost by preventing safe-related unexpected delay of construction due to the failure or collapse of retaining walls.

  • PDF

음영조건을 고려한 공동주택 옥상 태양광모듈의 배치계획 평가 연구 (Evaluation on the Photovoltaic Module Arrangement Planning Considering Shading Conditions in Apartment Buildings)

  • 이겨레;이윤선;임재한
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.169-179
    • /
    • 2019
  • During the initial design stage of apartment complex, the photovoltaic(PV) system has been considered as an alternative of renewable energy system and planned to install at the rooftop floor level in general. The electric power generation characteristics can be influenced by the block layout, building orientation and roof top structure because of azimuth angle, tilt angle, and partial shading. This study aims to investigate power generation characteristics of photovoltaic system in apartment buildings by considering the partial shading conditions due to the block layout, building orientation and roof-top structures. For the photovoltaic module arrangement planning in rooftop floor level, shading areas were firstly analyzed due to the adjacent building structure. And the annual and seasonal power generation of PV system were analyzed through the PVsyst simulation results. The results show that shading period at the roof top surface can be increased due to the parapet and water tank. Initial design power capacity can be decreased by considering the daily insolation period and distance between PV modules through the shading simulation. As the number of PV modules decreases, the annual power generation can be decreased. However annual power generation per unit area of PV modules can be increased and performance ratio can be increased above 80%. Also the power generation of PV system can be critically affected by building orientation and the performance ratio can be drastically decreased in east-oriented buildings due to the shading problems caused by adjacent structures at roof top level such as parapet and water tank.

U-City 건설을 위한 LiDAR 자료를 이용한 도심지 도로교통소음 영향의 시뮬레이션 분석 (Noise Simulation of Road Traffic in Urban Area Using LiDAR Data for U-City Construction)

  • 조재명;이동하;윤홍식;이승헌
    • 한국측량학회지
    • /
    • 제25권3호
    • /
    • pp.199-205
    • /
    • 2007
  • 본 연구에서는 주요한 소음원의 하나인 도로교통소음의 도심지에서의 전파양상과 피해정도의 명확한 분석을 위해 항공 LiDAR자료를 이용하여 건축물이 포함되지 않은 지형자료(DEM; Digtal Elevation Model) 및 건축물 정보가 포함된 지형자료(DBM; Digital Building Model)를 각각 작성하고, 각 자료별로 소음영향평가를 수행하여 그 결과를 비교하였다. 그 결과, 건축물 정보가 없는 경우 도로교통소음의 전파로 인하여 연구대상지역의 약 60%의 면적이 60dB(A) 이상의 소음께 노출되는 것으로 분석되었으나. 건축물 정보가 있는 경우는 약 30% 정도의 면적만이 노출되는 것으로 분석되었다. 또한, 정온한 환경으로 인식되는$45{\sim}50dB$(A)소음도구간의 면적이 건축물이 없는 경우 0%에서 건축물이 있는 경우 43%로 나타나 건축물에 의해 도로교통소음의 전파양상이 크게 영향을 받는 것을 알 수 있었다. 따라서 정확한 도로교통소음의 영향을 예측하기 위해서는 건축물 형상에 대한 정보가 필수적으로 포함하여야 할 것으로 판단되었다. 이러한 연구의 결과를 토대로 향후 항공 LiDAR 측량 등을 통하여 전국적인 규모의 건축물 정보가 획득된다면, 도로교통량정보를 이용한 도로교통소음 영향평가를 효율적으로 수행할 수 있을 것으로 판단되며, 이는 U-City 등과 같은 대규모 도시건설에서 소음문제예방, 교통계획 및 시공계획 수립 등을 위한 기초자료로서 활용이 가능할 것이다.

바로크적 특성으로 본 한국 사찰건축 -공주 마곡사를 대상으로- (A Study oA study on the Baroquely characteristics in Korean Temple Architecture)

  • 고인룡;동재욱
    • 한국디지털건축인테리어학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • Purpose of this paper is to find the Baroquely characteristics in Korean Temple Architecture.(MA KOK-SA) We could find out the characteristics as follows; First, visual freedom and floating in the arrangement of the temple buildings through segmenting the axis. Second, tension of variations in size, distance, and frame. Third, diverse sceneries provided by Sequential(dynamic) view points. Fourth, visual process and sharp contrast between horizontality and verticality, and unexpected scenery, etc.

  • PDF

척도운용체계를 통해 본 18세기 화성건축의 건축구성에 관한 연구 (A Study on the Operating System of the Architectural Standard Scale of Length(尺度, Korean foot) used in the Hwasong City Wall in the 18th Century)

  • 이호락;이상해
    • 건축역사연구
    • /
    • 제6권2호
    • /
    • pp.65-77
    • /
    • 1997
  • The Hwasong City Wall was built for three years(1794-1796), but the real construction term was taken only 28 months. The wall and the buildings on the wall were built simultaneously, and the esttimated construction cost was highly restricted. These conditions were main factors for considering the high efficiency of construction productivity. This study examines these factors that are reflected in the operating system of the architectural standard scale of length, the architectural composition system in the Hwasong City Wall to reduce the construction cost. Through the study, following factors are found. 1.The rule of multiple proportion is found in the relationship between the partition distance, that is, span and the height of the girder which is related to the productivity of ready-made building members. 2.The ruling grade system of scale in the component members is found in the chang-bang(창방, penetration members)

  • PDF

Object Tracking for a Video Sequence from a Moving Vehicle: A Multi-modal Approach

  • Hwang, Tae-Hyun;Cho, Seong-Ick;Park, Jong-Hyun;Choi, Kyoung-Ho
    • ETRI Journal
    • /
    • 제28권3호
    • /
    • pp.367-370
    • /
    • 2006
  • This letter presents a multi-modal approach to tracking geographic objects such as buildings and road signs in a video sequence recorded from a moving vehicle. In the proposed approach, photogrammetric techniques are successfully combined with conventional tracking methods. More specifically, photogrammetry combined with positioning technologies is used to obtain 3-D coordinates of chosen geographic objects, providing a search area for conventional feature trackers. In addition, we present an adaptive window decision scheme based on the distance between chosen objects and a moving vehicle. Experimental results are provided to show the robustness of the proposed approach.

  • PDF

Conditional mean spectrum for Bucharest

  • Vacareanu, Radu;Iancovici, Mihail;Pavel, Florin
    • Earthquakes and Structures
    • /
    • 제7권2호
    • /
    • pp.141-157
    • /
    • 2014
  • The Conditional Mean Spectrum represents a powerful link between the seismic hazard information and the selection of strong ground motion records at a particular site. The scope of the paper is to apply for the city of Bucharest for the first time the method to obtain the Conditional Mean Spectrum (CMS) presented by Baker (2011) and to select, on the basis of the CMS, a suite of strong ground motions for performing elastic and inelastic dynamic analyses of buildings and structures with fundamental periods of vibration in the vicinity of 1.0 s. The major seismic hazard for Bucharest and for most of Southern and Eastern Romania is dominated by the Vrancea subcrustal seismic source. The ground motion prediction equation developed for subduction-type earthquakes and soil conditions by Youngs et al. (1997) is used for the computation of the Uniform Hazard Spectrum (UHS) and the CMS. The disaggregation of seismic hazard is then performed in order to determine the mean causal values of magnitude and source-to-site distance for a particular spectral ordinate (for a spectral period T = 1.0 s in this study). The spectral period of 1.0 s is considered to be representative for the new stock of residential and office reinforced concrete (RC) buildings in Bucharest. The differences between the Uniform Hazard Spectrum (UHS) and the Conditional Mean Spectrum (CMS) are discussed taking into account the scarcity of ground motions recorded in the region of Bucharest and the frequency content characteristics of the recorded data. Moreover, a record selection based on the criteria proposed by Baker and Cornell (2006) and Baker (2011) is performed using a dataset consisting of strong ground motions recorded during seven Vrancea seismic events.

Inter-story pounding between multistory reinforced concrete structures

  • Karayannis, Chris G.;Favvata, Maria J.
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.505-526
    • /
    • 2005
  • The influence of the inter-story structural pounding on the seismic behaviour of adjacent multistory reinforced concrete structures with unequal total heights and different story heights is investigated. Although inter-story pounding is a common case in practice, it has not been studied before in the literature as far as the authors are aware. Fifty two pounding cases, each one for two different seismic excitations, are examined. From the results it can be deduced that: (i) The most important issue in the inter-story pounding is the local effect on the external column of the tall building that suffers the impact from the upper floor slab of the adjacent shorter structure. (ii) The ductility demands for this column are increased comparing with the ones without the pounding effect. In the cases that the two buildings are in contact these demands appear to be critical since they are higher than the available ductility values. In the cases that there is a small distance between the interacting buildings the ductility demands of this column are also higher than the ones of the same column without the pounding effect but they appear to be lower than the available ductility values. (iii) It has to be stressed that in all the examined cases the developed shear forces of this column exceeded the shear strength. Thus, it can be concluded that in inter-story pounding cases the column that suffers the impact is always in a critical condition due to shear action and, furthermore, in the cases that the two structures are in contact from the beginning this column appears to be critical due to high ductility demands as well. The consequences of the impact can be very severe for the integrity of the column and may be a primary cause for the initiation of the collapse of the structure. This means that special measures have to be taken in the design process first for the critically increased shear demands and secondly for the high ductility demands.

인공 도로협곡 관측 자료를 활용한 전산유체역학모델 검증 (Verification of Computational Fluid Dynamics Model Using Observation Data in Artificial Street Canyon)

  • 김도형;홍선옥;이대근;이영곤;김백조
    • 대기
    • /
    • 제26권3호
    • /
    • pp.423-433
    • /
    • 2016
  • In this study, performance of a computational fluid dynamics (CFD) model is assessed from analysis on air flow pattern which is observed in the artificial street canyon. Field observations focusing on flows were conducted at an artificial street canyon in Magok region. For the observation of three-dimensional airflow structures, twelve three-dimensional wind anemometers (hereafter, CSAT3) were installed inside the street canyon. The street canyon was composed of two rectangular buildings with 35-m length, 4-m width, and 7-m height. The street width (distance between the buildings) is 7 m, making the street aspect ratio (defined by the ratio of building height to street width) of 1. For the observation of above-building wind, a CSAT3 was installed above the northwest-side building. Southwesterly, westerly and northwesterly were dominant in the street canyon during the observations. Because wind direction is parallel to the street canyon in the southwesterly case, westerly and northwesterly were selected as inflow directions in numerical simulations using a computational fluid dynamics model developed through the collaborative research project between National Institute of Meteorological Sciences and Seoul National University (CFD_NIMR_SNU). The observations showed that a well-structured vortex flow (skimming flow) and an evidence of a small eddy at the corner of the downwind building and ground appeared. The CFD_NIMR_SNU reproduced both the observed flow patterns reasonably well, although wind speeds inside the street canyon were underestimated.

Comparison of different codes using fragility analysis of a typical school building in Türkiye: Case study of Bingöl Çeltiksuyu

  • Ibrahim Baran Karasin;Mehmet Emin Oncua
    • Earthquakes and Structures
    • /
    • 제25권4호
    • /
    • pp.235-247
    • /
    • 2023
  • Bingöl, a city in eastern Türkiye, is located at a very close distance to the Karlıova Region which is a junction point of the North Anatolian Fault Zone and Eastern Anatolian Fault Zone. By bilateral step over of North Anatolian Fault Zone and Eastern Anatolian Fault Zone each other there occurred NorthWest-SouthEast extended right-lateral and NorthEast-SouthWest extended left-lateral fault zones. In this paper, a typical school building located in Bingöl Çeltiksuyu was selected as the case study. Information on the school building and Bingöl Earthquake (2003) have been given in the paper. This study aimed to determine the fragility curves of the school building according to HAZUS 2022, Turkish Seismic Codes 1998, 2007 and 2018. These codes have been introduced in terms of damage limits. Incremental dynamic analysis is a parametric analysis method that has recently emerged in several different forms to estimate more thoroughly structural performance under seismic loads. Fragility analysis is commonly using to estimate the damage probability of buildings. Incremental Dynamic Analysis have performed, and 1295 Incremental Dynamic Analysis output was evaluated to obtain fragility curves. 20 different ground motion records have been selected with magnitudes between 5.6M and 7.6M. Scaling factors of these ground motions were selected between 0.1g and 2g. Comparison has been made between HAZUS 2022 and Turkish Seismic Codes 1998, 2007 and 2018 in terms of damage states and how they affected fragility curves. TSC 1998 has more conservative strictions along with TSC 2018 than TSC2007 and HAZUS moderate and extensive damage limits.