• Title/Summary/Keyword: Distance Relay

Search Result 238, Processing Time 0.032 seconds

A Method to Improve the Speed of a Distance Relay Using Artificial Neural Networks (신경회로망을 이용한 거리 계전기의 속도 개선 방법)

  • Cho, K.R.;Kang, Y.C.;Kim, S.S.;Nam, S.R.;Park, J.K.;Kang, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.677-679
    • /
    • 1996
  • This paper describes a method to improve the speed of a distance relay based on a differential equation of transmission lines using feedforward artificial neural networks (ANN) on an EHV system. For the impedance calculation an integration approximation to the differential equation is used and then an ANN is trained with the impedance convergence characteristic. The ANN predicts the fault distance with some calculated resistances and reactances before they reach trip zone. Thus, the proposed method can improve the speed of distance relays, significantly if a high sampling rate such as 48 samples per cycle is employed.

  • PDF

Optimal Relay Selection and Power Allocation in an Improved Low-Order-Bit Quantize-and-Forward Scheme

  • Bao, Jianrong;He, Dan;Xu, Xiaorong;Jiang, Bin;Sun, Minhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5381-5399
    • /
    • 2016
  • Currently, the quantize-and-forward (QF) scheme with high order modulation and quantization has rather high complexity and it is thus impractical, especially in multiple relay cooperative communications. To overcome these deficiencies, an improved low complex QF scheme is proposed by the combination of the low order binary phase shift keying (BPSK) modulation and the 1-bit and 2-bit quantization, respectively. In this scheme, the relay selection is optimized by the best relay position for best bit-error-rate (BER) performance, where the relays are located closely to the destination node. In addition, an optimal power allocation is also suggested on a total power constraint. Finally, the BER and the achievable rate of the low order 1-bit, 2-bit and 3-bit QF schemes are simulated and analyzed. Simulation results indicate that the 3-bit QF scheme has about 1.8~5 dB, 4.5~7.5 dB and 1~2.5 dB performance gains than those of the decode-and-forward (DF), the 1-bit and 2-bit QF schemes, at BER of $10^{-2}$, respectively. For the 2-bit QF, the scheme of the normalized Source-Relay (S-R) distance with 0.9 has about 5dB, 7.5dB, 9dB and 15dB gains than those of the distance with 0.7, 0.5, 0.3 and 0.1, respectively, at BER of $10^{-3}$. In addition, the proposed optimal power allocation saves about 2.5dB much more relay power on an average than that of the fixed power allocation. Therefore, the proposed QF scheme can obtain excellent features, such as good BER performance, low complexity and high power efficiency, which make it much pragmatic in the future cooperative communications.

Optimal Relays for Cooperative ARQ Protocol Based on Threshold of Distance

  • Xuyen, Tran Thi;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4B
    • /
    • pp.215-223
    • /
    • 2008
  • Retransmission signals from relays to destination when the destination fails to decode received signal from the source in Automatic Repeat Request (ARQ) protocol make the destination receive signals more reliably. With using omni -direction antenna in the practical system, in communication range of both the source antenna and the destination antenna, there are some relays that can be used to transmit signal to the destination. However, using all relays to transmit signal consume power and bandwidth. In this paper, we propose a new protocol in which the best relays are chosen based on threshold of distance from the source to the relay and the relay to the destination when the relays use decode- and forward (DF) protocol. Simulation results prove the efficiency of the protocol when we compare using only the best relays with using all relays to transmit signal to the destination.

A Study on Distance Relay of Transmission with UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Park, Jeong-Ho;Jung, Chang-Ho;Shin, Dong-Joon;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.196-198
    • /
    • 2002
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault on transmission lines need to be detected, classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algorithm based multi-layer perceptron is utilized for the learning process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

  • PDF

Evaluation of Distance Relay Operation Characteristic with the Reduction Devices Installed in Underground Power Cable Systems (시스순환전류 저감장치 설치시 거리계전기 응동 특성 평가)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.494-496
    • /
    • 2003
  • This paper analyses the operation characteristic of distance relay when the single line to ground occurs in underground power cable systems that reduction device of sheath circulating current is installed. To apply that reduction device to actual system, the change of line impedance calculated at relay point is also analysed by the connection type of SVLs and fault location, fault inception angle with the installation of reduction device of reactor or not.

  • PDF

Digital Distance Relay with Adaptive Protection Zone (Adaptive보호범위를 가진 송전선로 보호용 디지털 거리계전기)

  • Jung, Chang-Ho;Lee, Jae-Gyu;Jung, Byung-Tae;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.893-895
    • /
    • 1998
  • This paper presents the adaptive setting method of distance relay under the single line ground fault. The apparent impedance measured at the relaying point and actual impedance is different because of fault resistance and various prefault loading condition. For a resistance earth fault detection, relay setting zone is adaptively changed with measured load current and bus voltage at the relaying point to avoid maloperation.

  • PDF

Simulation for the Efficient Utilization of Energy in Wireless Sensor Network (무선 센서네트워크에서의 효과적인 에너지 활용 시뮬레이션)

  • Baeg, Seung-Beom;Cho, Tae-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.14 no.3
    • /
    • pp.33-42
    • /
    • 2005
  • One of the imminent problems to be solved within wireless sensor network is to balance out energy dissipation among deployed sensor nodes. In this paper, we present a transmission relay method of communications between BS (Base Station) and CHs (Cluster Heads) for balancing the energy consumption and extending the average lifetime of sensor nodes by the fuzzy logic application. The proposed method is designed based on LEACH protocol. The area deployed by sensor nodes is divided into two groups based on distance from BS to the nodes. RCH (Relay Cluster Head) relays transmissions from CH to BS if the CH is in the area far away from BS in order to reduce the energy consumption. RCH decides whether to relay the transmissions based on the threshold distance value that is obtained as a output of fuzzy logic system, Our simulation result shows that the application of fuzzy logic provides the better balancing of energy depletion and prolonged lifetime of the nodes.

  • PDF

An amplify-and-forward relaying scheme based on network coding for Deep space communication

  • Guo, Wangmei;Zhang, Junhua;Feng, Guiguo;Zhu, Kaijian;Zhang, Jixiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.2
    • /
    • pp.670-683
    • /
    • 2016
  • Network coding, as a new technique to improve the throughput, is studied combined with multi-relay model in this paper to address the challenges of long distance and power limit in deep space communication. First, an amplify-and-forward relaying approach based on analog network coding (AFNC) is proposed in multi-relay network to improve the capacity for deep space communication system, where multiple relays are introduced to overcome the long distance link loss. The design of amplification coefficients is mathematically formulated as the optimization problem of maximizing SNR under sum-power constraint over relays. Then for a dual-hop relay network with a single source, the optimal amplification coefficients are derived when the multiple relays introduce non-coherent noise. Through theoretic analysis and simulation, it is shown that our approach can achieve the maximum transmission rate and perform better over single link transmission for deep space communication.

Outage Analysis and Optimization for Four-Phase Two-Way Transmission with Energy Harvesting Relay

  • Du, Guanyao;Xiong, Ke;Zhang, Yu;Qiu, Zhengding
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.10
    • /
    • pp.3321-3341
    • /
    • 2014
  • This paper investigates the outage performance and optimization for the four-phase two-way transmission network with an energy harvesting (EH) relay. To enable the simultaneous information processing and energy harvesting at the relay, we firstly propose a power splitting-based two-way relaying protocol (PSTWR). Then, we discuss its outage performance theoretically and derive an explicit expression for the system outage probability. In order to find the optimal system configuration parameters such as the optimal power splitting ratio and the optimal transmit power redistribution factor, we formulate an outage-minimized optimization problem. As the problem is difficult to solve, we design a genetic algorithm (GA) based algorithm for it. Besides, we also investigate the effects of the power splitting ratio, the power redistribution factor at the relay, and the source to relay distance on the system outage performance. Finally, extensive simulation results are provided to demonstrate the accuracy of the analytical results and the effectiveness of the GA-based algorithm. Moreover, it is also shown that, the relay position greatly affects the system performance, where relatively worse outage performance is achieved when the EH relay is placed in the middle of the two sources.

A Study on the Protective Relay Setting Rules for 765kV Power System by Analysis of Errors (765kV 송전계통 보호계전기의 오차분석을 통한 정정지침에 관한 연구)

  • 최면송;이승재;강상희;조성진;배영준;조범섭;유영식
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.50-57
    • /
    • 2003
  • In this paper, the protective relay setting rules of Korean electric power system are studied by analysis of errors to be considered. An accurate operation of protective relays with accurate settings are important in power system reliability. The setting rules are used from the first establishment in 1982 and revision in 1990 Therefore, it needs revise and analysis of the setting rules because of environmental changes such as voltage raise or applied new technology of power system. Two major setting rules are studied. One is the rule for Zones of distance relay for transmission lines. The other is the one of differential current in a differential relay for power transformers. The range of errors in the setting rules accepted in the field experience is studied in simulation of case study. Also some guide lines for the range of errors in the setting rules are presented from the case study using Matlab simulation.