• 제목/요약/키워드: Distal end

검색결과 283건 처리시간 0.029초

더덕의 체세포배발생에서 전형층분화와 자엽수의 관계 (Relationship of Cotyledon Number with Procambium Differentiation in Somatic Embryogenesis of Codonopsis lanceolata L.)

  • 최필선;소웅영;조덕이;유장렬
    • Journal of Plant Biotechnology
    • /
    • 제32권2호
    • /
    • pp.135-138
    • /
    • 2005
  • 더덕 자엽절편을 1 mg/L 2,4-D가 첨가된 MS기본배지에 배양하여 배발생캘러스를 얻었고, 호르몬이 첨가되지 않은 MS액체배지에서 구형기의 체세포배를 얻었다. 구형기에서 초기 심장형기로 발달할 때 자엽의 시원세포는 전형성층조직으로부터 분화되기 시작 하였으며, 하배축에서 관찰되는 원통형 전형성층대는 2개의 자엽을 형성할 경우 2개의 전형성층대가, 3개의 자엽은 3개의 전형성층대가, 4개의 자엽은 4개의 전형층대가 각각 독립적으로 분화되어 자엽절과 자엽부위까지 연결되어 있었다. 만약 구형기 체세포배에서 자엽시원세포가 원통형으로 분화될 경우 합생자엽을 갖는 체세포배가 형성되었다.

A Novel Roux-en-Y Reconstruction Involving the Use of Two Circular Staplers after Distal Subtotal Gastrectomy for Gastric Cancer

  • Hur, Hoon;Ahn, Chang Wook;Byun, Cheul Su;Shin, Ho Jung;Kim, Young Bae;Son, Sang-Yong;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • 제17권3호
    • /
    • pp.255-266
    • /
    • 2017
  • Purpose: Although Roux-en-Y (R-Y) reconstruction after distal gastrectomy has several advantages, such as prevention of bile reflux into the remnant stomach, it is rarely used because of the technical difficulty. This prospective randomized clinical trial aimed to show the efficacy of a novel method of R-Y reconstruction involving the use of 2 circular staplers by comparing this novel method to Billroth-I (B-I) reconstruction. Materials and Methods: A total of 118 patients were randomly allocated into the R-Y (59 patients) and B-I reconstruction (59 patients) groups. R-Y anastomosis was performed using two circular staplers and no hand sewing. The primary end-point of this clinical trial was the reflux of bile into the remnant stomach evaluated using endoscopic and histological findings at 6 months after surgery. Results: No significant differences in clinicopathological findings were observed between the 2 groups. Although anastomosis time was significantly longer for the patients of the R-Y group (P<0.001), no difference was detected between the 2 groups in terms of the total surgery duration (P=0.112). Endoscopic findings showed a significant reduction of bile reflux in the remnant stomach in the R-Y group (P<0.001), and the histological findings showed that reflux gastritis was more significant in the B-I group than in the R-Y group (P=0.026). Conclusions: The results of this randomized controlled clinical trial showed that compared with B-I reconstruction, R-Y reconstruction using circular staplers is a safe and feasible procedure. This clinical trial study was registered at www.ClinicalTrials.gov (registration No. NCT01142271).

고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구 (A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT)

  • 고현;우이형;박남수
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF

방사선 강내치료를 위한 소조사면 전자선cone의 선량분포 특성 (Fabrication and Dosimetry Characteristics of Intracavitary Cones for Radiotherapy)

  • 나수경;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.95-102
    • /
    • 2001
  • 방사선치료용 고 에너지 전자선의 조직내 선량분포는 매우 다양하게 나타나고 있으며 조직내에서 일정 깊이까지만 선량이 집중적으로 부여되고 그 이후에는 선량이 급감하는 특징으로 인하여 피부 및 피부에서 깊지않은 종양과 구강, 질강 등 강내조사에 존재하는 종양치료에 널리 이용되고 있다. 하지만 의료용 선형가속기에는 강내조사용 조사통(cone)이 제공되지 않고 있다. 본 실험은 2.5, 3.0, 3.5 cm ø 크기의 강내조사용 소조사면 조사통을 수직형과 30$^{\circ}$ 경사형으로 6가지를 직접 제작하여 에너지별, 조사통 크기별로 조직내 선량분포 특성을 실험하여 임상적 선량계획에 필요한 자료를 제공하는데 목적을 두고 실험하였다. 심부선량은 조사통 크기, 에너지 크기, 조사통 각도에 따라 다르게 나타나고 있으며 유효선량 깊이는 전자선 에너지 및 조사통이 커질수록 약간 증가하였고, X선 오염정도는 1.2% 이하로 나타났으며, 출력흡수선량율은 약 15-86 %로 나타났다. 고 에너지 전자선은 강내치료에 매우 유용하게 이용될 수 있으며, 조직내 선량분포 특성이 매우 다양한 양상을 나타내고 있음을 확인하였고 이러한 결과를 자료화하여 임상적 치료와 새로운 선량분포 모형 연구에 필요한 자료를 제공할 수 있으리라 생각한다.

  • PDF

한국재래산양의 전지골격에 관한 해부학적 연구 (Anatomical Studies on the Skeleton of Thoracic Limb of Korean Native Goat)

  • 김진상;이흥식;이인세
    • 대한수의학회지
    • /
    • 제27권2호
    • /
    • pp.167-183
    • /
    • 1987
  • The anatomical structure of the Skeleton of thoracic limb of thirty-one adult Korean native goats(body weight: 14~17kg) was observed after skeletal preparation, and the osteometry was performed in each bone. The results were as follows; 1. The thoracic limb of the Korean native goat was composed of scapula, humerus, radius, ulna, carpal bones, metacarpal bones, phalanges and sesamoid bones. 2. The scapula was flat and triangular in shape. There were no distinct tuber of spine and acromion in the spine. The subscapular fossa was deep and triangular in shape and the vertebral border was sigmoid form. The coracoid bone was formed as the coracoid process at the medial aspect of the supraglenoid tubercle but the clavicle wa.s not observed. The left and right scapular indexes were 57.92 and 58.31 and the glenoid cavity indexes were 89.23 and 86.82, respectively. 3. The greater tubercle of the humerus was devided into cranial and caudal parts. The third tubercle was observed and the face for the infraspinatus muscle was rectangular form. The left and right humerus indexes were 32.44 and 32.63, the head indexes were 94.13, 96.62 and the trochlear-epidondyle indexes were 67.32 and 65.81, respectively. 4. The radius and ulna were fused entirely except at the broad proximal and narrow distal interosseous spaces. The ulna was longer than the radius, and its reduced body and distal end were fused at the caudomedial surface of the radius. 5. The carpal bones were six in number. There were radial, intermediate, ulnar, accessory, second-third and fourth carpal hones in carpal bones. 6. The metacarpal bone was composed of a large metacarpal bone resulted from the fusion of the third and fourth metacarpal bones, and there was a metacarpal tubercle at the dorsolateral part of the proximal end. There were no vestiges of the second and fifth metacarpal bones. 7. The digits were composed of third and fourth digits and each digit was composed of the proximal, middle and distal phalanges. 8. The sesamoid bones were six in number. There were two at the fetlock joint and one at the coffine joint palmarly in each digit. 9. The ratios of the lengths among the scapula, humerus, antebrachium and metacarpal bone were 1.42 : 1.47 : 1.77 : 1.00 in the left and 1.42 : 1.45 : 1.77 : 1.00 in the right, respectively.

  • PDF

익수류 4종의 음경골 형태에 관한 기초연구 (Morphological Characteristics of Baculum in Four Bats)

  • 전영신;김성철;한상훈;정철운
    • 환경생물
    • /
    • 제35권1호
    • /
    • pp.95-99
    • /
    • 2017
  • 음경골은 일반적으로 종 내에서는 동일한 형태를 보이는 것으로 알려져 있으며, 이를 이용해서 박쥐의 종 분류 및 유연관계 확인 등 다양한 연구가 이루어지고 있다. 본 연구에서는 국내에 서식하는 익수류를 대상으로 지금까지 전혀 연구가 이루어지지 않았던 박쥐 음경골의 형태학적 특징에 대하여 고찰하였다. 연구결과 4종의 음경골 형태는 종에 따라서 분명하게 다른 형태를 보였는데, 안주애기박쥐의 음경골 길이가 평균 7.27 mm로 가장 길었으며, 다음으로 관박쥐, 검은집박쥐, 관코박쥐 순으로 나타났다. 음경골의 형태는 관박쥐가 Y자의 끝이 뾰족한 형태를 보였고, 안주애기박쥐는 길고 원뿔형의 형태를 나타냈다. 반면 검은집박쥐는 기부와 말단부의 폭이 중심축보다 더 넓은 형태를 보였고, 관코박쥐는 작고 타원형의 형태로 확인되었다. 형태 특징으로 볼 때 관박쥐, 안주애기박쥐, 관코박쥐는 정도의 차이는 있었으나 기부에서 말단으로 갈수록 폭이 좁아지는 형태를 보였다. 그러나 검은집박쥐는 말단부의 폭이 더 넓은 특징을 보였다. 또한 관박쥐와 검은집박쥐는 음경골의 중심축이 일직선 형태인 데 반하여 안주애기박쥐는 말단으로 갈수록 아래로 향하는 모습을 보였으며, 관코박쥐는 위를 향해서 휘어진 모습을 보였다. 결과적으로 본 연구에 이용된 4종의 음경골 형태는 종에 따라서 매우 특징적인 결과를 보였으며, 이는 향후 종별 동정키로의 이용 및 유연관계 파악을 위한 연구자료로 활용 가능할 것으로 판단된다. 또한 본 연구자료를 기초로 하여 외부 형태학적 유사성이 높은 Myotis속 내의 음경골 차이 비교와 같은 보다 심도 있는 연구가 연계되어야 할 것이다.

원형 봉합기를 이용한 위십이지장연결술 시 단측연결과 단단연결의 비교 (Comparison of End-to-side and End-to-end Anastomosis in Circular Stapled Gastroduodenostomy)

  • 서민우;김용진;송단;강길호;조규석;이문수;허경열;김재준
    • Journal of Gastric Cancer
    • /
    • 제9권2호
    • /
    • pp.57-62
    • /
    • 2009
  • 목적: 원형 봉합기를 이용한 위십이지장연결술의 가장 대표적인 두 가지 방법(단측연결과 단단연결)의 수술 후 결과를 토대로 그 장단점을 확인하고자 본 연구를 고안하였다. 대상 및 방법: 2005년 3월부터 2008년 2월까지 순천향 대학병원에서 위암 진단 하 위십이지장 연결술을 시행한 134명을 대상으로 하였다. 2005년 3월부터 2006년 9월까지는 연속적으로 단측연결을(단측군, 76명), 2006년 11월부터 2008년 2월까지는 연속적으로 단단연결을 시행했다(단단군, 58명). 두 군을 대상으로 전향적 자료 수집을 통해 수술후 경과를 비교 분석하였다. 결과: 두 근간 모든 임상병리학적 요인에 차이가 없었다. 평균 수술시간은 단측군이 157분($\pm56$), 단단군이 150분($\pm49$)이었으며, 입원기간의 경우 단측군이 10.5일($\pm3.5$), 단단군이 9.4일($\pm2.9$)로 이 역시 두 군간에 차이는 없었다. 합병증과 관련해서 전체적으로 단측군이 15예(19.7%), 단단군은 8예(13.8%)에서 발생하였으며(P=0.489), 연결부위 관련해서 단측군에서 출혈이 2예 및 협착이 2예 있었으며, 단단군의 경우 출혈이 2예에서 있었다(P=0.698). 결론: 원형 봉합기를 이용한 위십이지장연결술은 두 방법 모두 기술적으로 용이하며 안전하였다. 통계적 의의는 없었지만, 연결 부위 협착과 관련해서는 단측군에서만 2예 발생하여 단단군이 더 나은 경향을 보였다.

  • PDF

Nylon Thread를 이용한 mouse 에서의 Transient middle cerebral artery occlusion (MCAO) model 확립 (Transient Middle Cerebral Artery Occlusion Model in Mouse using Nylon Thread)

  • 임병철;성지희;김하나;박승우
    • 한국콘텐츠학회논문지
    • /
    • 제19권7호
    • /
    • pp.186-191
    • /
    • 2019
  • 서론: 최근 노년층에서 뇌졸중 발병률이 증가하고 있다. 현재 뇌졸중 치료제 및 방법이 많이 개발되어 있으나 치료 후에도 후유증 등이 많이 남게 된다. 그래서 아직도 많은 과학자나 임상 의사들이 이를 치료하기 위한 약물 및 방법을 연구하고 있는 실정이다. 많은 연구 중 뇌졸중 치료 연구를 위한 표준화된 실험 동물연구는 드물며, 표준화된 Nylon thread를 이용한 중대뇌동맥 폐쇄모델(MCAO, middle cerebral artery occlusion)의 성공률에 대한 연구는 거의 없다 방법: 본연구는 $0.18{\pm}0.02mm$의 지름을 가진 5-0 Nylon thread를 중대뇌동맥에 삽입하였다. 60분 동안 삽입한 후에 봉합해 놓았던 부위를 다시 절개하여 Nylon thread를 빼내고, 막았던 혈관의 매듭을 풀어주어, 다시 혈액이 공급되게 하였다. 그로부터 23시간 후에 뇌를 내어 1mm 두께로 자른 후 1.5% TTC(2',3',5'-triphenyl-tetrazolium chloride)로 15분간 염색하고, 4% PFA(paraformaldehyde)로 15분 동안 고정하였다. 결과: Nylon thread를 삽입하여, MCA occlusion 50마리, ICA occlusion 14마리, 제대로 된 MCAO model보다 좀 더 깊게 들어간 distal MCAO model 36마리, 너무 깊은 MCA나 ACA까지 들어가서 상보적인 괴사를 나타내는 occlusion model 1마리, 그리고 경색이 일어나지 않은 마우스 50마리를 확인하였다. 결론: 이에 본 연구에서는 Nylon Thread를 생쥐의 무게에 따라 32~36g 인 생쥐는 9mm로 삽입하여주고, 37~40g인 생쥐는 9mm+0.5mm의 깊이로 삽입하여서 1hr의 occlusion과 23hr의 reperfusion을 주어 생쥐를 TTC 염색을 통하여 괴사가 일어난 부분을 확인하였고, 생쥐에서 가역적인 뇌혈관 경색으로 151말중 101마리에서 뇌경색을 유도 할 수 있었다(66.9%).

TMA wire로 제작된 3종류의 MVLAW(Multi-Vertical Loop Arch Wire)의 초기응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF 3 TYPES TMA MULTI-VERTICAL LOOP ARCH WIRE)

  • 이형철;전윤식
    • 대한치과교정학회지
    • /
    • 제25권1호
    • /
    • pp.73-85
    • /
    • 1995
  • 교정치료시 치축의 개선을 위한 많은 연구와 노력이 이루어져 왔다. 본 교실에서는 치축개선을 위해 MEAW를 응용한 Multi-Vertical Loop Arch Wire(MVLAW : 엠빌로)를 수년 전부터 다수치아의 치축을 동시에 개선코자 사용해 왔다. MVLAW는 일종의 근심경사된 치아를 세우는 장치로써 open vertical loop를 3가지 종류로 변형시켜 적용시켜 왔으며 이를 각각 A, B, C형으로 명명하였다. 각 MVLAW는 .017"x.025" TMAwire로 제작되며, A형 MVLAW의 경우 각 open vertical loop의 apex를 10도 정도 벌려주어 활성화시키며(electric welding stop을 각 loop의 근심측에 위치시킨다), B형과 C형 MVLAW의 경우 open vertical loop의 원심측에 10도의 tip back bend를 형성함으로써 활성화시킨다(B형의 경우 electric welding stop이 각 loop의 원심측에 형성되는 반면 C형의 경우 electric welding stop을 형성하지 않는다). 본 연구는 구치부의 치축을 동시에 개선코자할 때 MVLAW를 3가지 종류로 분류한 후 각 MVLAW의 효과를 알아보고자 상하악 1/2악을 광탄성 모형에 재현하여 그 응력분포를 관찰하여 다음과 같은 결론을 얻었기에 보고하는 바이다. 1. A형 MVLAW의 경우 3급 견인고무를 걸지 않았을 경우 하악 제1대구치와 제2대구치 치근의 원심면에서 강한 응력분포를 나타내나 전치부에 발생한 미약한 응력분포는 3급 견인고무의 장착으로 상쇄되었다. 따라서 A형 MVLAW는 초기에 치관의 직립효과가 있는 것으로 보인다. 2. B형 MVLAW의 경우 3급 견인고무를 걸지 않았을 경우 각 치아의 근심측에 응력분포를 보이며 견인고무를 걸었을 때와 비교시 전치부에 증가된 응력분포를 보였다. 따라서 B형의 경우 초기에 치근의 직립효과가 있는 것으로 보인다. 3. C형 MVLAW의 경우 3급 견인고무를 걸지 않았을 경우 하악전치부를 제외하고는 응력분포를 나타내지 않았으나 견인고무를 걸었을 경우 주로 견치와 소구치 근심면에서 응력분포를 보였다. 따라서 C형의 경우 견인고무 사용시 초기에 견치와 소구치에서 치근의 직립효과가 있는 것으로 보인다.

  • PDF

Degeneration Exists along the Entire Length of the Supraspinatus Tendon in Patients with a Rotator Cuff Tear

  • Jo, Chris Hyunchul;Chang, Mee Soo
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.61-67
    • /
    • 2015
  • Background: The purposes of the study were to examine rotator cuff tendon degeneration with respect to harvesting location, to determine a rationale for debridement of the torn end, and thus, to determine adequate debridement extent. Methods: Twenty-four patients with a full-thickness rotator cuff tear were included in the study. Tendon specimens were harvested during arthroscopic rotator cuff repair from three locations; from torn ends after minimal regularization of fraying (native end group, NE group), from torn ends after complete freshening of the frayed end (freshened end group, FE group), and from the macroscopically intact portion just distal to the musculotendinous junction (musculotendinous junction group, MTJ group). Control samples were harvested from patients admitted for surgery for proximal humerus fracture. Harvested samples were evaluated using a semi-quantitative grading scale. Results: Mean total degeneration scores in the NE group ($13.3{\pm}3.21$), the FE group ($12.5{\pm}2.30$), and in the MTJ group ($10.8{\pm}3.10$) were significantly higher than those in the normal control group ($5.0{\pm}2.87$; all p<0.001). Mean total degeneration score in the NE group was significantly higher than that in the MTJ group (p=0.012), but was not from that of the FE group. Mean total degeneration score in the FE group was not significantly different from that of the MTJ group. Conclusions: Tendon degeneration exists throughout the entire tendon to the macroscopically intact portion of full-thickness rotator cuff tear. Therefore, aggressive debridement to grossly normal appearing, bleeding tendon is unnecessary for enhancing healing after repair.