• Title/Summary/Keyword: Dissolved air flotation

Search Result 92, Processing Time 0.03 seconds

Effect of Coagulation and Homogenization on the Dissolved Air Flotation and Sedimentation of Bulking Sludge (응집과 균질화가 팽화슬러지의 용존공기부상과 침전에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.68-74
    • /
    • 2007
  • The objective of this study is to examine the effect of the coagulation and homogenization in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effects of parameters such as dosage of coagulant and homogenization time were examined. The results showed that DAF and sedimentation was affected aluminum sulfate and anion polymer coagulant differently. At the optimum dosage of aluminum sulfate, thickening efficiency of DAF and sedimentation process were increase 1.25 time and 2.02 time, respectively. At the optimum dosage of anion polymer coagulant, thickening efficiency of DAF process was increase 1.35 time, but thickening efficiency at sedimentation was 1.06 time. When anion polymer coagulant of 0.5 mg/l was added in DAF process, water content of sludge was decreased from 96.6% to 90.7% in dewatering process using Buchner funnel test device. After homogenization(20500 rpm, 10 min), Sauter mean diameter of sludge floc was decreased from 631 ${\mu}m$ to 427 ${\mu}m$, however increase of flotation efficiency by DAF was only 1.09 time.

Flotation Separation of Biological Floc Using the Dissolved Air Flotation Process (용존공기부상(DAF) 공정을 이용한 생물학적 플록의 부상분리)

  • Kwak, Dong-Heui;Kim, Seong-Jin;Lim, Young-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.649-655
    • /
    • 2004
  • The behavior of biological particles in DAF (dissolved air flotation) process was analyzed by employing PBT (Population balance theory). After decline growth phase of activated sludge, the value of the initial collision-attachment efficiency was increased over than 0.35 corresponding relatively high value in the whole life cycle of microorganism. For practical application of DAF as a solid separation process. It is desirable that microbial particles should be operated to perform high solid removal efficiency in biological wastewater treatment.

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Simulation study of DAF flotation basin using CFD (전산유체해석기법을 이용한 용존공기부상공정의 유동해석)

  • Park, Byungsung;Woo, Sungwoo;Park, Sungwon;Min, Jinhee;Lee, Woonyoung;You, Sunam;Jun, Gabjin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species (유입원수 조류제거를 위한 high rate DAF 최적화 연구)

  • Jung, Woosik;An, Ju-Suk;Song, Keun-Won;Oh, Hyun-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

A Study for Application of DAF Technology to Remove Chrolophyl-a and Dissolved Organic Compound in Yongdam Reservoir (용담호소 내 Chlorophyl-a와 유기물 저감을 위한 부상기법 적용 연구)

  • Dockko, Seok;Lee, Hyungjib
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.303-309
    • /
    • 2006
  • Yongdam reservoir located in Jeoliabuk-do has had a lot of concerns for its algal blooming since it has started to fill water. Many water utilities near Yongdam area use reservoirs even though they have some problems with certain algae that cause tastes and odors and clog filters. In this research, dissolved air flotation (DAF) technology was examined for feasibility for removal of algae. OAF can save the capital cost for its compactness, because its hydraulic loadings (overflow rates) are 10 times higher than sedimentation, and hydraulic detention times are much shorter, typically 5 to 15 minutes. As a result of this research, PAC is effective rather than Alum to DAF for pretreatment. Higher DOC plays an important role to change zetapotential negatively to inhibit destabilization of particle to coagulation. The length of pipeline to carry pressurized water into reactor does not affect reaction.

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

Operation Conditions for Continuous DAF Process with Domestic DAF Pump (국산 DAF 펌프가 적용된 연속 DAF 공정의 운전 조건)

  • An, Dae Myung;Lee, Chang Han;Ahn, Kab Hwan;Cho, Seok Ho;Kim, Seong-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.242-246
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density particles, such as algal flocs, humus materials and clay particles produced from low turbidity water. The fraction of humic substances for natural organic matters (NOMs) are considered problematic in water because it can readily react with chlorine to form harmful by-products (trihalomethanes) and can be exposed to undesirable color, tastes and odors in drinking water. A broad class of NOMs includes fulvic acid, humic acid and humin. This paper will discuss the results from a study that performed with a DAF pump process using synthetic wastewater contained humic substance. Batch jar tests were performed to evaluate coagulant dose and recycle ratio on flotation efficiency.

The Study on the Humic Acid Removal using Underwater Plasma Discharge (수중 방전을 이용한 휴믹산 제거)

  • Hong, Eunjung;Chung, Paulgene;Ryu, Seungmin;Park, Junseuk;Yoo, Seungryul;Lho, Taihyeop
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.367-374
    • /
    • 2012
  • A flotation process has a shorter processing time and needs less space than a sedimentation process. Dissolved air flotation process (DAF) is an efficient flotation method and used in a conventional wastewater treatment process. However, DAF requires the circulation of water containing compressed air and requires expensive installation and operation cost. Plasma Air Flotation (PAF) process is able to float flocs by micro bubbles generated from underwater plasma without the circulation of bubbly water and additional saturators. Therefore, PAF can be an alternative solution overcoming economic barriers. In this study, Humic acid removal efficiency by PAF process was compared with that of sedimentation process. 44.67% and 87.3% reduction rate based on UV 254 absorbance has been measured in sedimentation and PAF respectively. In particular, PAF in the flocculation zone can dramatically remove humic acid from water. In flocculation zone, PAF can separate organic matters but sedimentation cannot.