• 제목/요약/키워드: Dissection, acute

Search Result 130, Processing Time 0.025 seconds

Aortic Surgery without Infusion of Cardioplegic Solution at Total Circulatory Arrest

  • Lee, Hae Young;Kim, Dong Jin
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Background: Minimal infusion of cardioplegic solution (CPS) during aortic surgery using total circulatory arrest (TCA) may reduce several potential side effects: clamping on a diseased aorta, insult of coronary ostia, and edema. Materials and Methods: From 2006 to 2009, 72 patients underwent aortic surgery without infusion of cardioplegic solution at the initiation of circulatory arrest. The diagnoses were acute aortic dissection (44), aneurysm (22), and intramural hematoma (6). Results: The duration of TCA, the lowest nasopharyngeal temperature, bypass time, and aortic clamp time was 45 minutes, $16.4^{\circ}C$, 162 minutes, and 100 minutes, respectively. The amount of CPS was 1,050 mL, and 15 patients underwent surgery without CPS. The average inotrope score was 113 points (range, 6.25 to 5,048.5 points) corresponding to the dopamine infusion of 5 mcg/kg/min for 1 day. Seven patients showed a level of creatine kinase-MB above 50 ng/mL, postoperatively, compared with the average of 12.75 ng/mL. The ischemic change was found on electrocardiogram in 5 patients, postoperatively. There was no cardiac morbidity requiring mechanical assist. The average of intensive care unit stay and postoperative hospital stay was 40 hours (range, 15 to 482 hours) and 11 days, respectively. Conclusion: Minimal infusion of only retrograde CPS during rewarming without initial infusion at TCA in aortic surgery is feasible and can be used with acceptable results.

Neobladder-vaginal Fistula Repair with Modified Martius Bulbocavernosus Fat Pad Flap (변형 Martius 구해면체 지방피판술을 이용한 신생방광-질루의 치험례)

  • Myung, Yu-Jin;Park, Ji-Ung;Jeong, Eui-Cheol;Kim, Suk-Wha
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.329-332
    • /
    • 2011
  • Purpose: In developed countries, vesicovaginal fistula occur from various pelvic operations including total hysterectomy, leading to urinary leakage and incontinence. Although various methods have been proposed for adequate tissue coverage in fistula repair, the surgical treatment of is not simple and still controversial. We report a case of neobladder-vaginal fistula repair using modified Martius fat pad flap. Methods: A 62-year-old female patient underwent radical cystectomy with total abdominal hysterectomy and neobladder formation due to invasive bladder tumor 5 years ago. For 3 years following the operation, urine leakage was observed. Exploration demonstrated neobladder-vaginal fistula and primary repair including fistulectomy and direct closure was performed. Urinary incontinence relapsed 2 years after primary repair, and after demonstrating the recurrence of fistula on urography, repair of recurrent fistula was performed. After dissection of vagina and neobladder and closure of fistula by urologic surgeon, fibroadipose flap was elevated, rotated and advanced through the tunnel at vaginal sidewall, and interpositioned to the fistula site between neobladder and vagina. Results: There was no acute complication after the surgery and urethral catheter was extracted on the 8th day after the operation. During six month follow-up period after the operation, there is no clinical evidence of fistula recurrence. Conclusion: From our clinical experience and literature review, we think Martius fat pad flap is a useful technique in management of neobladder-vaginal fistula, for it provides enough vascularity, major epithelization surface and better lymphatic drainage, and also prevents overlapping of vesical, vaginal suture lines at the same time.

Delayed Diagnosis of Cardiac Tamponade That Was Caused by Intramural Hematoma of the Ascending Aorta -A case report- (상행대동맥 벽내 혈종에 의해 발생한 심낭 압전의 지연 진단 - 1예 보고 -)

  • Hwang, Yoo-Hwa;Song, Suk-Won;Yi, Gi-Jong
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.194-198
    • /
    • 2010
  • Intramural hematoma of the aorta (IMH) is the precursor or a variant of a classic aortic dissection where hemorrhage occurs within the aorta wall in the absence of an initial intimal tear. IMH has a high rate of mortality and morbidity. The optimal therapy for IMH is uncertain, yet the involvement of the ascending aorta is usually considered as an indication for surgery due to the associated risk of rupture or cardiac tamponade. We report here on a case of a 71-year-old man who presented with syncope. Because of misdiagnosis, he underwent computed tomography (CT) after 5 hrs from arriving to the ER. Computed tomography of the aorta revealed intramural hematoma of the ascending aorta with cardiac tamponade. He also had vascular complications such as acute renal failure and visceral ischemia. We performed emergency graft replacement of the total arch and ascending aorta. He was discharged without complication on postoperative day 14.

Use of an Interposition Tube Graft for the Reattachment of Left Coronary Ostium to the Aortic Composite Valve Graft. -One Case- (Aortic Composite Valve Graft의 이식시 인조혈관을 이용한 좌 관상동맥의 문합술 1례 보고)

  • Kim, Chang-Nam;Choe, Jong-Beom;Choe, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.646-650
    • /
    • 1996
  • The usual methods for the re-attachment of coronary ostia to the ascending aortic conduit have several disadvantages and potential complications. A novel, straight forward technique is described that allows for tension free anastomoses to be co structed with minimal risk of blood loss and a reduced risk of reoperation for false aneurysms at the anastomoses. We performed this technique for the treatment of a 40-yrs-old male patient of acute aortic dissection (Stanford Type A, DeBakey Type I) with severe aortic re- gurgitation. The techinque comprised anastomosis of a beveled interposition tube graft to the left main coronary artery ostium, and its proximal anastomosis to the ascending aortic graft after seating the com- posite valve graft in the prepared aortic annulus. With this technique, the low-Iying or distant left main coronary ostium can be easily reattached to the ascending conduit without undue tension.

  • PDF

Medical Service Based on AR and VR (가상 증강현실 기반의 의료서비스)

  • Yeon, YunMo;Woo, SungHee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.803-806
    • /
    • 2016
  • 'Pokemon Go',which is game program, provides a clue to solve the problem of healthcare in the sense of leading changes in behavior of the users. 'Pokemon Go'is a spin-off of the $Pok{\acute{e}}mon$ game series and uses Augmented Reality(AR) technology. AR, which can be said to complement the real world, has been used in many fields such as medical applications, broadcasting, manufacturing, the mobile sector as a wide range of technologies. In particular, the medical field as area of the active application from the start of AR, provides a great help in medical fields, that is accurate medical diagnosis and prevention of unnecessary dissection by synthesizing the patient information and the image of actual patient on three-dimensional data of the sensor such as MRI or ultrasonic wave. In this study, we analyze the VR technology trends, application examples, and the future of VR and AR based medical services in healthcare.

  • PDF

Recurrent Ischemic Strokes with Progression of Middle Cerebral Artery Stenosis during HIV Treatment (사람면역결핍바이러스감염증 치료 중 발생한 중대뇌동맥협착의 악화 및 재발성 뇌경색)

  • Kang, Jongsoo;Kim, Min Ok;Yi, Jeong Jin;Park, Min Won;Kim, Chang Hun;Kim, Young-Soo;Park, Kee Hong;Kang, Hee-Young;Choi, Nack-Cheon;Kwon, Oh-Young;Kim, Soo-Kyoung
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.337-340
    • /
    • 2018
  • Human immunodeficiency virus (HIV) infection can result in ischemic stroke via several mechanisms, including opportunistic infection, vasculopathy, cardioembolism, and coagulopathy. HIV-vasculopathy is related to endothelial dysfunction, stenosis and aneurysm formation, infectious vasculitis, dissection and accelerated atherosclerosis during highly active antiretroviral therapy (HAART). We represent a case of HIV infection manifested as an acute ischemic stroke attack. After 4 months during HAART, our patient experienced a recurrent ischemic stroke with progression of middle cerebral artery stenosis.

Delayed Sternal Closure Using a Vacuum-Assisted Closure System in Adult Cardiac Surgery

  • Hyun Ah Lim;Jinwon Shin;Min Seop Jo;Yong Jin Chang;Deog Gon Cho;Hyung Tae Sim
    • Journal of Chest Surgery
    • /
    • v.56 no.3
    • /
    • pp.206-212
    • /
    • 2023
  • Background: Delayed sternal closure (DSC) is a useful option for patients with intractable bleeding and hemodynamic instability due to prolonged cardiopulmonary bypass and a preoperative bleeding tendency. Vacuum-assisted closure (VAC) has been widely used for sternal wound problems, but only rarely for DSC, and its efficacy for mediastinal drainage immediately after cardiac surgery has not been well established. Therefore, we evaluated the usefulness of DSC using VAC in adult cardiac surgery. Methods: We analyzed 33 patients who underwent DSC using VAC from January 2017 to July 2022. After packing sterile gauze around the heart surface and great vessels, VAC was applied directly without sternal self-retaining retractors and mediastinal drain tubes. Results: Twenty-one patients (63.6%) underwent emergency surgery for conditions including type A acute aortic dissection (n=13), and 8 patients (24.2%) received postoperative extracorporeal membrane oxygenation support. Intractable bleeding (n=25) was the most common reason for an open sternum. The median duration of open sternum was 2 days (interquartile range [25th-75th pertentiles], 2-3.25 days) and 9 patients underwent VAC application more than once. The overall in-hospital mortality rate was 27.3%. Superficial wound problems occurred in 10 patients (30.3%), and there were no deep sternal wound infections. Conclusion: For patients with an open sternum, VAC alone, which is effective for mediastinal drainage and cardiac decompression, had an acceptable superficial wound infection rate and no deep sternal wound infections. In adult cardiac surgery, DSC using VAC may be useful in patients with intractable bleeding or unstable hemodynamics with myocardial edema.

Clinical Outcomes of Minimally Invasive Surgical Stabilization of Rib Fractures Using Video-Assisted Thoracoscopic Surgery

  • Chae-Min Bae;Shin-Ah Son;Yong Jik Lee;Sang Cjeol Lee
    • Journal of Chest Surgery
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2023
  • Background: Multiple rib fractures are common in blunt chest trauma. Until recently, most surgical rib fixations for multiple rib fractures were performed via open thoracotomy. However, due to the invasive nature of tissue dissection and the resulting large wound, an alternative endoscopic approach has emerged that minimizes the postoperative complications caused by the manipulation of injured tissue and lung during an open thoracotomy. Methods: Our study concentrated on patients with multiple rib fractures who underwent surgical stabilization of rib fractures (SSRF) between June 2018 and May 2020. We found 27 patients who underwent SSRF using video-assisted thoracoscopic surgery. The study design was a retrospective review of the patients' charts and surgical records. Results: No intraoperative events or procedure-related deaths occurred. Implant-related irritation occurred in 4 patients, and 1 death resulted from concomitant trauma. The average hospital stay was 30.2±20.1 days, and ventilators were used for 12 of the 22 patients admitted to the intensive care unit. None of the patients experienced major pulmonary complications such as pneumonia or acute respiratory distress syndrome. Conclusion: Minimally invasive rib stabilization surgery with the assistance of a thoracoscope is expected to become more widely used in patients with multiple rib fractures. This method will also assist patients in a quick recovery.

Clinical and Angiographic Outcomes of Endovascular Treatment for Acute Intracranial Vertebral Artery Dissecting Aneurysms Using Double-Overlapping Stents : Low-Profile Visualized Intraluminal Support within Enterprise Stents

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.5
    • /
    • pp.531-540
    • /
    • 2024
  • Objective : The use of reconstructive treatment with a double-overlapping stents has proven to be effective and safe in the current treatment of intracranial vertebral artery dissecting aneurysms (VADAs). We employed a combination of overlapping stents, using low-profile visualized intraluminal support (LVIS) within the Enterprise stent. This combination was chosen to minimize the outward bulging of the inner LVIS by overlapping it with the Enterprise stent while maintaining flow diversion and stability. This study aimed to evaluate the clinical and angiographic outcomes following the use of double-overlapping stents with LVIS within the Enterprise stent for the treatment of VADAs. Methods : From March 2016 to January 2022, total 28 patients with unruptured VADAs were treated with the double-overlapping stent technique using LVIS within an Enterprise stent in our institute. The Enterprise stent was deployed first, followed by the LVIS stent. Patient clinical and angiographic characteristics, procedural complications, and follow-up outcomes were retrospectively reviewed. Results : All 28 patients (18 males and 10 females) were successfully treated with double-overlapping stent deployment. There were no procedural complications or new neurological deficits in any patient. Of the 28 patients, four VADAs had posterior inferior cerebellar artery involvement. Procedure-related parent artery occlusion did not occur during the angiographic follow-up conducted 6 to 12 months after the procedure. Out of 28 patients, 24 showed complete healing, three had focal residual stenosis or dilatation with residual sac and only one had a residual dissecting flap with aneurysm. All patients, including the four patients, did not require any additional procedures. The postoperative modified Rankin scale scores were 0-1 for all patients. Conclusion : A double-overlapping stent, with a flow-diversion effect, is a safe and effective treatment for patients with VADAs. In particular, when using the LVIS stent within an Enterprise stent, it minimizes the bulging of the inner LVIS stent while maintaining flow diversion and stability. Therefore, both can be effectively utilized as overlapping stents.

Surgical Treatment of the Descending Thoracic Aorta ; An analysis of 22 cases (하행 흉부 대동맥류의 외과적 치료; 22예의 분석)

  • 이홍섭;이선훈;윤영철;구본일;김창호
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.532-535
    • /
    • 1999
  • Background: The purpose of this study was to evaluate and analyze the surgical techniques and postoperative complications in patients undergoing operations for descending thoracic aortic aneurysms. Material and Method: The data of 22 major operations between March 1987 and August 1997 were retrospectively reviewed. Result: There were 18 men and 4 women with a mean age of 49 years (range 33 years to 82 years). The cause of the aneurysm was aortic dissection in 13 patients, atherosclerosis in 3, mycotic in 3, trauma in 2 and uncertain in 1. The operative techniques were resection and graft replacement in 16, axillofemoral bypass graft in 2, femorofemoral bypass graft in 2, exclusion, aneurysmorrhaphy in 1 and transfemoral stent insertion in 1. During the operation, 16 cases were performed under total aortic clamp. Among the 16 patients, femorofemoral bypass was used in 14 cases and previously made shunt in 2 cases. The mean total aortic clamp time was 91 minutes and the mean extracorporeal circulation time was 116 minutes. One death occurred in an excluded patient on the 52 postoperative day due to a rupture of the aneurysm. Postoperative complications were paraplegia in 1 case, acute renal failure in 1 case and acute respiratory failure in 1 case. Conclusion: Although surgical treatment of the descending thoracic aneurysm has many postoperative complications, good surgical results can be achieved with a proper patient selection and fine surgical techniques.

  • PDF