중.저준위 방사성폐기물의 천층처분을 위한 인공방벽 실증시험시설의 건설 및 운전 경험 (Construction and Operational Experiences of Engineered Barrier Test Facility for Near Surface Disposal of LILW)

  • Jin-Beak Park;Se-Moon Park;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제2권1호
    • /
    • pp.23-34
    • /
    • 2004
  • To validate the previous conceptual design of cover system, construction of the engineered barrier test facility is completed and the performance tests of the disposal cover system are conducted. The disposal test facility is composed of the multi-purpose working space, the six test cells and the disposal information space for the PR center. The dedicated detection system measures the water content, the temperature, the matric potential of each cover layer and the accumulated water volume of lateral drainage. Short-term experiments on the disposal cover layer using the artificial rainfall system are implemented. The sand drainage layer shows the satisfactory performance as intended in the design stage. The artificial rainfall does not affect the temperature of cover layers. It is investigated that high water infiltration of the artificial rainfall changes the matric potential in each cover layer. This facility is expected to increase the public information about the national radioactive waste disposal program and the effort for the safety of the planned disposal facility.

  • PDF

중.저준위 방사성폐기물 천층처분을 위한 처분덮개의 성능실증 시험시설 개념설계 (A Conceptual Design on Performance Test Facility of Disposal Cover for the Near Surface Disposal of Low and Intermediate Level Radioactive Waste)

  • 이찬구;박세문;김창락;염유선;이은용
    • 지질공학
    • /
    • 제11권3호
    • /
    • pp.245-254
    • /
    • 2001
  • 처분덮개는 중.저준위 방사성폐기물 천층처분시설의 성능 유지에 중요한 역할을 하므로 여러가지 시험과 장기관측을 통한 처분덮개의 성능실증 연구는 시설의 안전성 확보에 불가결한 요소이다. 처분덮개의 기본적인 성능요건으로는 불투수성, 건전성, 열화에의 저항력 및 유지보수의 용이성 등을 고려할 수 있다. 이러한 성능요건을 단일층으로는 충족하기 어려운 점을 고려하여 HELP(Hydrologic Evaluation of Landfill Performance) 코드를 사용한 물수지 평가를 통해 상부 보호층, 중간 배수층 및 하부 저투수층 등으로 구성된 다층덮개 개념을 도출하였다. 처분덮개 내에서의 수분이동특성을 규명하기 위해 TDR(Time Domain Reflectometry)과 Tensiometer를 사용하여 각각 함수비와 matric potential의 변화를 3$\times$3$\times$3.3m 크기의 6개 시험고에서 장기관측 할 수 있도록 설계하였다.

  • PDF

Water Balance Evaluation of Final Closure Cover for Near- surface Radioactive Wastes Disposal Facility

  • Keunmoo Chang;Park, Joo-Wan;Yoon, Jeong-Hyoun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.274-282
    • /
    • 2000
  • The simulation of water balance was conducted for suggested four alternative multi-layer cover design of near-surface radioactive waste disposal facility under domestic climate condition. The analysis was also conducted for the most favorable one out of four alternative cover design under conservative scenarios. Until 100 years after closure of disposal vault, the infiltration flux for the most favorable cover design was negligible even under doubling of the ambient precipitation condition. When the degradation of asphalt and geomembrane after 100 years of closure was considered, the infiltration flux significantly increased almost to the design criteria of cover system in I' Aube disposal facility. And it was found that the hydraulic conductivity of bentonite/sand as a bottom barrier should be no greater than 1$\times$10$^{-7}$ cm/sec recommended by U.S. EPA.

  • PDF

Artificial Rainfall Test of the Engineered Cover Barriers for Near Surface Disposal of LILW

  • Park, Jin-Beak;Park, Se-Moon;Kim, Chang-Lak
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.306-314
    • /
    • 2003
  • Engineered barrier test facility is specially designed to demonstrate the performance of engineered barrier system for the near-surface disposal facility under the domestic environmental conditions. Comprehensive measurement systems for the water content, temperature, matric potential are installed within each test cell. In this study, short-term monitoring of the behavior of multi-layered cover system is implemented with artificial rainfall system. The periodic measurement data are collected and analyzed by a dedicated database management system, and provide a basis for performance verification of the disposal cover design.

  • PDF

역사시대 고분을 이용한 중저준위 방사성폐기물의 천층처분 덮개성능 자연유사연구 (A natural analog study on the cover-layer performance for near-surface LILW disposal by considering the tomb of historical age)

  • 박진백;박주완;김창락;양시은;이선복
    • 방사성폐기물학회지
    • /
    • 제3권4호
    • /
    • pp.279-291
    • /
    • 2005
  • 중저준위 방사성폐기물 천층처분시설의 처분덮개설계 및 성능평가를 위해 국내 역사시대 고분연구를 수행하였다. 처분덮개 성능과 관련된 국내외 연구현황을 조사하고 삼국시대 고분을 중심으로 봉분의 층상특성을 정리하였다. 국내 고분에 대한 봉토의 시료채취와 시료에 대한 수리전도도 측정 및 분석을 실시하였다. 고분에 대한 자연유사 연구에서 발굴조사보고서 상에 제시된 봉토의 유사판축기법의 적용, 모세관 방벽현상과 배수로를 이용한 봉분 내 습도조절 여부를 천층처분 시설설계에 활용할 수 있을 것으로 판단된다. 향후 국내 고분발굴현장이 있을 때 현장을 방문하여 필요한 자료수집과 더불어 원자력분야의 관심사와 필요사항에 대하여 국내 고고학계와의 정보교환이 이루어져야 할 것으로 판단된다.

  • PDF

경주 중저준위방폐장 2단계 처분시설의 불포화 환경하에서 침투수 유동 해석 (Simulation of Unsaturated Fluid Flow on the 2nd Phase Facility at the Wolsong LILW Disposal Center)

  • 하재철;이정환;윤정현
    • 방사성폐기물학회지
    • /
    • 제15권3호
    • /
    • pp.219-230
    • /
    • 2017
  • 본 연구는 경주 중 저준위처분장 2단계 표층처분시설의 폐쇄 후 안전성에 대한 불확실성을 예측 평가하기 위하여 수행되었다. 다중덮개와 처분고의 건전/열화를 고려한 총4가지의 시나리오를 도출하여 강우침투 시 예상되는 처분시설 내부의 유체 이동을 모사하였다. 강우 조건은 총 30년(1985~2014) 간의 월평균 데이터를 적용하였으며, 시뮬레이션 기간은 제도적 관리기간인 300년으로 설정하였다. 처분덮개와 처분고 콘크리트 모두 건전성을 유지하는 조건의 기본 시나리오 평가 결과, 처분시설 내부의 처분고를 완전히 포화시키지 못하는 것을 확인할 수 있었다. 다중 덮개층을 구성하는 8개 층의 각 매질의 모세관 압력과 투과도 차이로 인하여 다중 덮개층이 효과적으로 차수 배수 역할을 하는 것으로 나타났다.

다양한 시나리오 기반 유체거동 수치모사를 통한 중·저준위 방사성 폐기물 표층처분시설 안전성 평가 (Safety Assessment of Near Surface Disposal Facility for Low- and Intermediate-Level Radioactive Waste (LILW) through Multiphase-Fluid Simulations Based on Various Scenarios)

  • 정진아;권미진;박은규
    • 자원환경지질
    • /
    • 제51권2호
    • /
    • pp.131-147
    • /
    • 2018
  • 본 연구에서는 중 저준위 방사성 폐기물 표층처분시설의 방사성 핵종 누출에 대한 안전성을 검증하기 위해 덮개층 및 처분고의 구조적 특성 및 물성이 고려된 유체거동 수치모사를 실시하였다. 유체거동 수치모사를 통해 시설 내 침투수거동 양상을 모사한 후, 덮개층 및 처분고 구조물 경계면을 따라 침투수 흐름 선속을 정량적으로 산정함으로써 방사성 핵종 누출의 위험성이 평가되었다. 또한 발생 가능한 시설 설계조건 및 외부 환경 변화가 고려된 다양한 시나리오 기반 수치모사를 실시함으로써 구축된 표층처분시설의 안전여유도 평가 또한 실시되었다. 그 결과, 본 연구에서 이용된 설계 구조가 표층처분시설의 안전적 운영에 적합한 것을 확인하였으며, 다양한 시나리오 기반 다중 수치모사 결과를 통해 덮개층과 처분고 수리특성의 건전성 유지 여부가 시설 안전성에 지대한 영향을 미침을 확인하였다. 특히, 처분고 콘크리트 벽체의 열화상황에서 처분고 내부로의 침투수 흐름을 관찰함으로써 처분고의 차수기능이 처분시설 안전성에 중요한 영향을 미치는 것으로 판단된다.