• 제목/요약/키워드: Disposable equipment

검색결과 20건 처리시간 0.022초

A Disposable BioChip for Single Cell Manipulation

  • Yoon, Euisik
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 International Symposium
    • /
    • pp.1-15
    • /
    • 2004
  • o Various microfluidic components including mixromixers and micropumps have been developed for disposable biochip applications. o Single cell capturing, positioning and nanoliter drug injection chip has been demostrated. o Multi-channel, two-dimensional micro-well array has been fabricated and cell capturing and specific reagent injection have been performed.

  • PDF

가정간호 대상자의 의료 기구사용에 관한 조사연구 (Personal Use of Medical Equipment in Home Care Patients)

  • 임난영;김금순
    • 기본간호학회지
    • /
    • 제6권1호
    • /
    • pp.64-77
    • /
    • 1999
  • This study was conducted to investigate the use of medical equipment in patients receiving home care service. The subjects of this study were 88 patients cared by seven home care nursed who were registered in the Seoul Nurses Association. Data was collected from Aug. 1, 1998 to Dec. 30, 1998. The findings are as follows. 1. The sample was found to be 55.7% female : 51.7% over 65 years old. 75% with neurologic disease including CVA, brain tumor, ICH, Parkinsonism & Spinal stenosis and 78.4% living in Seoul. The Clinical experience of the home care nurses was greater than five years. 2. Medical equipment which the patients possessed were foley catheters(61.4%), L-tubes(59.1%) and tracheostomy tubes(51.1%). 3. Technical difficulties in use of medical equipment were related to home care ventilators(60.0%), L-tubes(3.8%) and tracheostomy tubes(2.2%). 4. Most of the medical equipment were obtained from the hospital where they had been admitted previously or from medical equipment companies. 5. Complications from the use of this equipment were infection through invasive techniques including wound drainage tubes(50%), and IV injections(22.2%), The complications were resolved through referral to the doctor of the hospital where they were previously admitted or through community health centers. 6. Most of the equipment was disposable, and equipment was disinfected by using various methods including boiling and soaking in antiseptic solutions. These findings suggest that consistant policy on the management of medical equipment is necessary for the safety of home care patients.

  • PDF

The Development of Radiopharmaceutical Synthesizer and its FDG Synthesis Verification

  • Jong Min Kim;Il Koo Cheong;Chan Soo Park;Hee Seup Kil;Cheol Soo Lee
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.87-93
    • /
    • 2022
  • [18F]FDG is known as the most widely used radiopharmaceutical in the imaging field of nuclear medicine worldwide. With the introduction of PET equipment, the demand for [18F]FDG has increased and the production volume has also increased. However, in order to increase production, the use of 18F radioisotope must be increased or [18F]FDG must be synthesized in high yield. Therefore, in order to meet the high yield and purity of radiopharmaceuticals, a radiopharmaceutical automatic synthesizer was required. As the use of [18F]FDG increased, automated synthesizer manufacturers supplied various types of radiopharmaceutical automated synthesizers to the market. In this study, we developed a commercialized [18F]FDG radiopharmaceutical automatic synthesizer (sCUBE FDG) using a disposable cassette type that complies with GMP developed by FutureChem, a leading radiopharmaceutical company. We used sCUBE FDG to verify the production process, radiopharmaceutical's quality (radiochemical purity, etc.), and radiochemical yield of [18F]FDG. As a result of optimizing the automatic synthesis process and synthesizing a total of 30 times, the production time was 35 ± 3 minutes and the average production yield was 65.6%.

Infection Risks Faced by Public Health Laboratory Services Teams When Handling Specimens Associated With Coronavirus Disease 2019 (COVID-19)

  • Wong, Chun-Kwan;Tsang, Dominic N.C.;Chan, Rickjason C.W.;Lam, Edman T.K.;Jong, Kwok-Kwan
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.372-377
    • /
    • 2020
  • Infection risks of handling specimens associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by public health laboratory services teams were assessed to scrutinize the potential hazards arising from the work procedures. Through risk assessments of all work sequences, laboratory equipment, and workplace environments, no aerosol-generating procedures could be identified except the procedures (mixing and transfer steps) inside biological safety cabinets. Appropriate personal protective equipment (PPE) such as surgical masks, protective gowns, face shields/safety goggles, and disposable gloves, together with pertinent safety training, was provided for laboratory work. Proper disinfection and good hand hygiene practices could minimize the probability of SARS-CoV-2 infection at work. All residual risk levels of the potential hazards identified were within the acceptable level. Contamination by gloved hands was considered as a major exposure route for SARS-CoV-2 when compared with eye protection equipment. Competence in proper donning and doffing of PPE accompanied by hand washing techniques was of utmost importance for infection control.

3년제 간호교육과정의 실험실습 기자재 기준 개발 (A STUDY ON THE DEVELOPMENT OF STANDARD CRITERIA OF EQUIPMENT FOR 3 YEAR NURSING EDUCATION)

  • 전시자;권숙희;김연화;박연숙;오세영;이숙희;인경선;최병순;추수경;홍영혜
    • 대한간호
    • /
    • 제37권3호
    • /
    • pp.78-91
    • /
    • 1998
  • This descriptive study was conducted in order to develop a standard criteria for nursing laboratory facilities and equipment for use by the 3 year nursing colleges. The data was collected from Aug. 28 to Sept. 30, 1997 by mail from 44 3 year nursing schools. To develop a standard criteria, the syllabi for Fundamentals of Nursing laboratory and for Physical Assessment were collected and analyzed. The following information was elicited and analyzed by the researchers : 1. for each procedure in the syllabus, the percentage of schools using the procedures 2. the facilities and equipment recognized as necessary and the percentage of schools which possess each item 3. calculation of the standard criteria for size of the nursing laboratory together with a list of the necessary facilities and equipment. The results of the study were as follows : 1. The Size of facility was 181.2m2 for fundamentals of Nursing laboratory and 56.4m2 for the storage room. For those whose number of students exceed 120, 1.98m2 is required for each students. 2. The number of items included in the standard criteria was 92 for Fundamentals of Nursing and Physical Assessment and 47 for other nursing subjects. The items made of rubber, plastic and the disposable ones were suggested but excluded from the standard criteria. Based on the above findings, the following suggestions were made : 1. Periodic review of the standard criteria is necessary to update the standard. 2. A study on the standardization of the curriculum for basic science laboratory, including experiment and a standard criteria of equipment, is necessary. 3. A study to develop a computer program for management of nursing laboratory facilities and equipment is needed.

  • PDF

Survey of the real-world re-use of disposable dental supplies in dental offices

  • Park, Bo-Young;Mun, So-Jung;Chung, Won-Gyun;Choi, Eun-Sil;Noh, Hie-Jin
    • 한국치위생학회지
    • /
    • 제19권1호
    • /
    • pp.141-149
    • /
    • 2019
  • Objectives: To investigate the real-world re-use of disposable dental supplies (DDS) in dental offices and assess the relationship between general characteristics of dental hygienists and reuse of DDS, with respect to infection control characteristics. Methods: A questionnaire was administered to 277 dental hygienists to assess their general characteristics, awareness of infection control/DDS management, and re-use of DDS. Nine DDS were categorized into the following categories based on their purpose: Critical, Semicritical, Noncritical, and Personal protective equipment (PPE). The association between general characteristics of dental hygienists and re-use of DDS, with respect to infection control characteristics, was assessed using the chi-squared test. Results: All 9 DDS were re-used to different extents. The highest reuse rate of supplies were for masks (64.6%), prophylaxis cups (61.0%) and plastic saliva ejectors (30.0%). Overall, 89.5% of the participants re-used DDS; subgroup analysis showed the following proportions of specific DDS re-use: PPE 66.4%; Semicritical DDS 63.9%; Noncritical DDS 19.5%; and Critical DDS 1.8%. Based on the type of clinic, the rate of re-use was higher in dental clinics than dental hospitals. Thus, the re-use of DDS may be caused by inappropriate or nonexistent guidelines or habitual practice, rather than the awareness or attitude of dental hygienists. Conclusions: In order to ensure a safe environment within the dental clinic, DDS classifications must be clearly outlined in the dental infection control guidelines; moreover, additional studies are needed regarding the regulations for DDS re-use and disposal.

서울시내 사업체 단체급식소의 노동생산성 지수 평가에 관한 연구 (Assessment of the Labor Productivity Indicies for Industry Foodservice Establishments in Seoul)

  • 최선욱
    • 대한가정학회지
    • /
    • 제30권3호
    • /
    • pp.79-89
    • /
    • 1992
  • Indicies of the labor productivity were assessed from 80 industry foodservice erstablishments in terms of meals served per labor hour, labor minutes per meal served, and labor cost per meal served. The labor productivity indicies were also assessed according to variables related to work such as working hours, paryment for the workers, volume of feeding, utilization of foodservice equipment, use of processed foods, and background of employees. The summary of the results was as follows: 1. Manufacturing sector among surveyed industry foodservice showed the highest labor productivity indicies followed by training institute. 2. 28.8% of surveyed establishments used dishwashing machine, while manual dishwashing was used in 71.3% of subjects, equipped rate point was 9.8 out of 20, and disposable dish was used in 30% of subjects. 3. A significant positive relationship was found between the number of meals and the labor procductivity indicies. As the number of meals increased, more meals were served per worker as per labor hour. 4. A significant negative relationship was found between price of meal and the labor productivity didicies. As the price of meal increased, less meals were served per worker as well as per labor hour.

  • PDF

A PRACTICAL METHOD FOR THE DISPOSAL OF RADIOACTIVE ORGANIC WASTE

  • Kim, Kil-Jeong;Shon, Jong-Sik;Ryu, Woo-Seog
    • Nuclear Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.731-736
    • /
    • 2007
  • Radioactive organic wastes containing acetone, alcohol, and particularly tributyl phosphate (TBP)/dodecane contaminated with uranium are extracted from the PUREX process and the decontamination of related equipment. An evaporation method that utilizes existing DU oxidation apparatuses and ventilation systems and a typical muffle furnace installed with an aspirating system are adopted. A separation method using phosphoric acid especially for the TBP/dodecane waste is also studied and evaluated. The results show that a simple evaporation process is utilizable for wastes containing acetone or alcohol with a lower boiling point. A modified muffle furnace is more appropriate to dispose directly of organic wastes having a higher boiling point, such as TBP/dodecane, without generating a condensed waste solution. It is recommended that, when the uranium concentration of TBP/dodecane waste is much higher than stipulated levels, separation technology should be applied to remove uranium from the mixture. Each type of solvent after separation can then be considered disposable below the regulatory limit in the modified furnace discussed in this study.

대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태 (Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu)

  • 은정화;배지영
    • 한국치위생학회지
    • /
    • 제5권2호
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

소리 공명 교육을 위한 주사기 실험기구 개발 (Development of the Syringe Experiment Device for the Education of Sound Resonance)

  • 윤기상;한재호;서상준;서재갑
    • 과학교육연구지
    • /
    • 제37권1호
    • /
    • pp.233-243
    • /
    • 2013
  • 이 연구의 목적은 기주의 길이와 공명주파수의 관계를 정량 분석할 수 있는 교육용 실험기구를 개발하는 것이다. 일회용 플라스틱 주사기와 분자모형 조립용 플라스틱 구를 이용하여 '머리' 달린 기주 공명 장치를 제작하고 상용화된 소프트웨어를 이용하여 PC 실험시스템을 구성하였다. 연구 결과, PC 실험시스템은 전문가용 장비를 대신할 수 있는 것으로 나타났다. 주사기로 만든 이 실험기구는 '관'이 아닌 '헬름홀쯔 공명기'인 것으로 증명되었다. 실험으로 얻은 자료가 소리공명현상을 증명할 수 있는 것으로 나타났다. 결론적으로, 이 주사기 공명기는 중고등학생을 위한 영재교육이나 대학 음향실험용으로 사용가능한 실험장치이다.

  • PDF