• 제목/요약/키워드: Displacement Period

Search Result 533, Processing Time 0.03 seconds

A new practical equivalent linear model for estimating seismic hysteretic energy demand of bilinear systems

  • Samimifar, Maryam;Massumi, Ali;Moghadam, Abdolreza S.
    • Structural Engineering and Mechanics
    • /
    • 제70권3호
    • /
    • pp.289-301
    • /
    • 2019
  • Hysteretic energy is defined as energy dissipated through inelastic deformations during a ground motion by the system. It includes frequency content and duration of ground motion as two remarkable parameters, while these characteristics are not seen in displacement spectrum. Since maximum displacement individually cannot be the appropriate criterion for damage assessment, hysteretic energy has been evaluated in this research as a more comprehensive seismic demand parameter. An innovative methodology has been proposed to establish a new equivalent linear model to estimate hysteretic energy spectrum for bilinear SDOF models under two different sets of earthquake excitations. Error minimization has been defined in the space of equivalent linearization concept, which resulted in equivalent damping and equivalent period as representative parameters of the linear model. Nonlinear regression analysis was carried out for predicting these equivalent parameter as a function of ductility. The results also indicate differences between seismic demand characteristics of far-field and near-field ground motions, which are not identified by most of previous equations presented for predicting seismic energy. The main advantage of the proposed model is its independency on parameters related to earthquake and response characteristics, which has led to more efficiency as well as simplicity. The capability of providing a practical energy based seismic performance evaluation is another outstanding feature of the proposed model.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

화학적 영향을 고려한 토목섬유-지반 접촉면의 동적상대변위 (Dynamic Relative Displacement of Geosynthetic-Soil Interface Considering Chemical Effect)

  • 곽창원;오명학;장동인;박인준
    • 한국지반공학회논문집
    • /
    • 제32권11호
    • /
    • pp.73-81
    • /
    • 2016
  • 최근 늘어나고 있는 폐기물량에 따라 해상 폐기물 매립장의 건설이 연구되고 있으며, 매립장 내 폐기물의 보강 및 보호 목적으로 토목섬유가 널리 사용되고 있다. 토목섬유는 흙과의 접촉면을 형성하는데 지진시 접촉면에서의 동적 전단 거동이 폐기물 매립장의 지진시 거동 및 안정성을 지배하는 가장 중요한 요소이다. 따라서 접촉면 동적 전단거동 및 동적상대변위 파악이 매우 중요하다. 이러한 접촉면 거동은 주위 환경 및 하중조건에 의해 영향을 받으며 복잡한 응답을 보이므로 이론적 접근이 곤란하다. 본 연구에서는 침출수 내의 산성 및 염기성과 같은 성분이 반복 전단하중 상태에서 지반-토목섬유 접촉면의 동적 상대변위특성에 대하여 실내 시험을 수행하고 그 결과를 분석하였다. 이를 위하여 동적 접촉면 전단 시험기를 이용하여 산성 및 염기성 용액에 840일 장기수침 시료와 60일 단기수침시료에 대하여 반복 단순전단 시험을 수행 하였다. 그 결과 산성 및 염기성 조건 공통적으로 산성일 경우 접촉면의 상대변위가 가장 큰 값을 나타내어 접촉면 손상 정도의 크기가 상대적으로 큰 것으로 나타났다.

COD(Crack Opening Displacement) 측정을 통한 강재의 피로균열진전속도 추정에 관한 실험적 연구 (Experimental Study on Evaluation of Fatigue Crack Growth Rate of Steel Plates using Crack Opening Displacement)

  • 김광진;김인태;류용열
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.589-597
    • /
    • 2010
  • 강구조물의 점검시 피로균열이 발견되는 경우에는 보수 보강 시행의 결정과 구조물의 점검주기 결정을 위한 균열의 현재 상태평가와 앞으로의 균열진행 정도에 대한 정량적인 예측이 요구된다. 피로균열에 대한 손상도 평가는 파괴역학 파라미터를 이용한 균열진전속도와 취성파단의 여부 결정이 대표적인 방법으로 파괴역학에 관한 전문적인 지식과 함께 수치해석 프로그램의 활용능력이 필요하다. 이에, 본 연구에서는 피로손상도 평가 방법에 관한 다양성을 확보하고, 파괴역학에 대한 전문적인 지식이 없는 기술자가 피로균열에 의한 강구조물의 손상도를 간편하게 평가 할 수 있는 방법을 개발하기 위한 첫 단계로, 관통균열 시험편을 이용한 균열진전시험을 실시하였다. 그리고 피로균열 표면으로부터 측정된 COD(Crack Opening Displacement)의 크기와 측정위치를 이용하여, 균열진전속도를 추정하기 위한 파라미터를 도출하고, 그 타당성을 분석하였다. 그리고 관통균열이 있는 시험편의 형상, 응력범위, 그리고 응력비에 상관없이 COD를 이용하여 피로균열진전속도를 추정할 수 있는 방법을 제시하였다.

굴착사면의 안정해석과 보강설계법 (Stability Analysis and Reinforced Design Method of Excavation Slopes)

  • 강예묵;이달원;조재홍
    • 한국농공학회지
    • /
    • 제38권5호
    • /
    • pp.140-154
    • /
    • 1996
  • In this study, displacement, deformation, and stability according to change of cohesion and internal friction angle were investigated through elasto-plastic method, finite-element method, and in-site experiment when excavating soft ground using sheet pile. The results of the study were as follows : 1. The horizontal displacement was 5.5% of the excavation depth by the elasto-plastic method and 3.9% of the excavation depth by the on-site experiment at the final excavation depth(GL-8.Om) on the condition of double stair strut after excavating GL-6.Om. 2. Relationships between cohesion(c) and internal friction angle $({\varphi})$ when safety factor to the penetration depth was 1.2 is shown in the following equations : (a) c= -O.0086$({\varphi})$+ O.3(D=3m) and (b) c=-0.00933$({\varphi})$+0.14(D=4m). 3. The results of elasto-plastic method and the experiment show that possible excavation depth was GL-6.Om after setting single stair strut in a short period in terms of possibility of carrying out on the condition of experimental site on the contrary general reinforcement method, setting double stair strut after excavating GL-4.0m. 4. After setting the strut, distribution of the horizontal displacement had concentrated on the excavation base and possible local failure which the shear strain caused decreased by the strut reinforced. 5. After setting strut, displacement of sheet pile was decreased by half, the limit of stable excavation depth of ground was GL-8.Om, and the maximum horizontal displacement at the GL-8.Om was 1.6% of excavation depth by the elasto-plastic method, 0.7% of excavation depth by the finite-element method.

  • PDF

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Dynamic analysis of offshore wind turbines

  • Zhang, Jian-Ping;Wang, Ming-Qiang;Gong, Zhen;Shi, Feng-Feng
    • Wind and Structures
    • /
    • 제31권4호
    • /
    • pp.373-380
    • /
    • 2020
  • For large-scale 5MW offshore wind turbines, the discrete equation of fluid domain and the motion equation of structural domain with geometric nonlinearity were built, the three-dimensional modeling of the blade considering fluid-structure interaction (FSI) was achieved by using Unigraphics (UG) and Geometry modules, and the numerical simulation and the analysis of the vibration characteristics for wind turbine structure under rotating effect were carried out based on ANSYS software. The results indicate that the rotating effect has an apparent effect on displacement and Von Mises stress, and the response and the distribution of displacement and Von Mises stress for the blade in direction of wingspan increase nonlinearly with the equal increase of rotational speeds. Compared with the single blade model, the blade vibration period of the whole machine model is much longer. The structural coupling effect reduces the response peak value of the blade displacement and Von Mises stress, and the increase of rotational speed enhances this coupling effect. The maximum displacement difference between two models decreases first and then increases along wingspan direction, the trend is more visible with the equal increase of rotational speed, and the boundary point with zero displacement difference moves towards the blade root. Furthermore, the Von Mises stress difference increases gradually with the increase of rotational speed and decreases nonlinearly from the blade middle to both sides. The results can provide technical reference for the safe operation and optimal design of offshore wind turbines.

COD(Crack Opening Displacement) 측정에 의한 강재표면의 피로균열진전속도 평가 (Evaluation of Fatigue Crack Growth Rate on the Surface of Steel Members Using COD(Crack Opening Displacement) Measurement)

  • 김광진;김인태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.179-188
    • /
    • 2011
  • 강부재의 피로가 주요원인이 되어 구조물이 붕괴되거나 교체되는 사례를 찾아보기 어렵다. 이처럼 사실상 피로에 대해서는 손상을 허용하고 있지만, 발견되는 피로균열에 대한 직접적인 상태평가는 이루어지지 않고 있다. 피로균열에 대한 진전 비진전성의 판단 및 균열진전속도의 평가가 이루어져야만, 합리적인 보수 보강 공법의 선정과 시행시기가 결정될 수 있을 것이다. 본 연구에서는 측정되는 COD(Crack Opening Displacement)를 통한 피로균열진전속도 평가법을 검토하기 위하여, 2종류의 관통 균열 시험편과 면외거셋 용접이음 시험편의 균열진전시험을 실시하였다. 그리고 실용적인 COD의 측정을 위해 변형률 게이지를 이용하는 방법에 대해 검토하였다. 그 결과, COD 측정을 통한 균열진전속도의 합리적인 평가법을 제안하였고, 변형률 게이지를 이용한 성공적인 COD 측정을 실험적으로 증명하였다.

강관압입후 슬롯 홀을 갖는 비개착 터널공법의 현장적용에 관한 연구 (A Study on Sites Application of Non-open-cut Tunnel Method with Slot Holes in Steel Pipe Pumping)

  • 채영석;송관권;민인기
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.47-51
    • /
    • 2015
  • In the study, a new non-open cut tunnel steel pipe method using slot hole has been developed. As is overcomes shortcomings of conventional methods, it is applied to the field. The main concept of the new method is the steel pipe pumping system with slot holes which, by means of formation slot holes between each steel pipe, applied to the magnitude of the relaxed earth pressure caused by excavation to the ground to prevent ground displacement. The stability of the support members and effect of displacement control of the new method were verified through several ways as numerical analysis and site test. The new method was applied to the construction of a 11.5m wide, 7.4m high and 50m long section that passes side subway and large buildings in inner city. By applying the new method, tunnel construction was successfully completed in 6 months. It decreases the construction period to 30% compared to that of conventional methods, and ground was almost negligible.

Change of Glycosaminoglycan Distribution and Collagen Fibers Arrangement on Temporomandibular Joint Following Anterior Disc Displacement of the Rabbits

  • Kim, Uk-Kyu;Chung, In-Kyo;Kim, Kyu-Cheon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권3호
    • /
    • pp.173-179
    • /
    • 2012
  • Purpose: This study was to determine the effects of surgical induction of anterior disc displacement (ADD) on the distribution of glycosaminoglycan (GAG) and collagen fiber arrangement in the rabbit temporomandibular joint (TMJ) tissues including articular cartilage of condyle, disc, retrodiscal tissue, and articular eminence. Methods: We used van Gieson staining and Alcian blue critical electrolyte concentration (CEC) method to observe change of collagen fibers on disc and to measure GAG up to 10 weeks in TMJ tissues after surgical induction of ADD on 25 rabbits. Results: CEC measurements for GAG showed 0.3 M, 0.4 M, 0.6 M, and 0.8 M at 1 week, 2 weeks, 3, 4, and 8 weeks, 10 weeks, respectively. This result indicated that GAGs shifted to highly sulphated ones as time passed. Disruption of collagen fiber arrangement in the disk occurred at 10 days and aggravated at 3 weeks. Conclusion: Our study showed degenerative osteoarthritis changes in rabbit TMJ following surgical induction of ADD up to 10-week period.