• Title/Summary/Keyword: Dispensing process

Search Result 67, Processing Time 0.029 seconds

Development of Dispenser System with Electrohydrodynamic and Voice Coil Motor for White Light Emitting Diode (백색 LED 제조를 위한 정전기력과 보이스코일모터를 이용한 디스펜서 시스템 개발)

  • Kang, Dong-Seong;Kim, Ki-Beom;Ha, Seok-Jae;Cho, Myeong-Woo;Lee, Woo-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6925-6931
    • /
    • 2015
  • LED(Light Emitting Diode) is used in various filed like a display because of low power consuming, long life span, high brightness, rapid response time and environmental-friendly characteristic. General fabrication method is combination blue light LED chip with yellow fluorescent substance. Because this way is suitable for industry field in terms of convenience, economic, efficiency. In white light LED packaging process, encapsulation process that is dispensing fluorescent substance with silicon to blue light LED chip is most important. So, in this paper we develop EHD pump system using voice coil motor and electrostatic pump for dispensing fluorescent substance. For these things we conduct basic test about liquid surface profiles by voltage and process time. Through this data we decide optimal process condition and verify the optimal condition using design of experiment method. And to confirm uniformity of the condition, we conduct repeat dispensing test.

Measurement of Microbic Contamination Rate in the Dispensing Process Making Suspension of Barium Sulfate Powder (분말 형태의 황산바륨을 현탁액으로 조제하는 과정에서 발생하는 미생물의 오염도 측정)

  • Kim, Young-Keun;Lee, Yang-Sub;Cho, Cheong-Chan;Ryu, Meung-Sun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete, and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus colt were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured, Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensible to manufacturing suspension for preventing from infection.

  • PDF

Wear Characteristics for Rod and Nozzle of Jetting Dispenser Driven by Dual Piezoelectric Actuators Under High Frequency with Phosphor-containing Liquid (형광체 함유 용액 고속 토출 조건에서의 듀얼 압전 디스펜서 공이와 노즐의 마모 특성 평가)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;An, Jun-Wook;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • An ultra-high precise ejection process is essential in a dispensing system for fabricating various precision parts such as a semiconductor, LED, and camera module. The size of such parts has been decreasing, which implies that a precise ejecting technique is required. A phosphor-containing liquid is ejected via a dispenser using dual piezoelectric actuators that are used for generating a high-speed dispensing mechanism. The rod and nozzle continuously contact in high speed to eject the liquid. However, the high-strength filler or phosphor in the liquid causes wear on the surfaces of the rod and nozzle during the dispensing process. As a result, the ejection reliability decreases as the wear on the surfaces increases. Therefore, it is necessary to estimate the wear characteristics of the rod and nozzle via an experiment and FE analysis. Reliability rests up to 1,000 cycles are conducted under relatively severe conditions. The flow rate and surfaces roughness of the rod and nozzle are measured in each ejection cycle. The surface images and wear volume are obtained before and after the tests and the ejection reliability is confirmed by measuring the flow rate of the liquid. The experimental results show that the ejection reliability is maintained up to 1,000k cycles; these results are validated by the simulation results.

Analysis of Effects of Chemotherapy using Failure Mode and Effect Analysis (FMEA) on Patient Safety and Safe Nursing (고장유형영향분석을 활용한 항암화학요법의 환자안전간호 효과분석)

  • Yang, Nam Young;Lee, Mi Hyang
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.21 no.3
    • /
    • pp.254-262
    • /
    • 2015
  • Purpose: This study was done to apply failure mode & effect analysis (FMEA) to chemotherapy in order to reduce prescribing, dispensing and administering errors related to treatment and provide patients with a safe medical environment. Methods: A one group pre-post test design was used to verify the effects using the tool for FMEA in chemotherapy. Results: There was a statistically significant decrease in prescribing errors from 11.47% to 3.18%; administering errors decreased but they were not statistically significant. In a addition, there was no change in dispensing errors. Conclusion: The results show that FMEA removed risk factors that might occur during the process of chemotherapy and that it was an effective tool for prevention of negligent accident occurring in actual patients.

A Study of High Viscosity Phosphor Dispensing for an Electrostatic Printing System (전기수력학 프린팅 시스템을 이용한 고점도 형광체의 정량 토출 연구)

  • Kim, S.W.;Yang, Y.J.;Dang, H.W.;Yang, B.S.;Kim, H.B.;Choi, K.H.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2015
  • For chromaticity correction, it is necessary to dispense high viscosity phosphor slurry since it greatly affects the performance of white LEDs. However, it is quite difficult to dispense high viscosity fluorescent materials. In the current study, micro-discharge electrostatic printing has been used for dispensing various high viscosity phosphor slurries. We have achieved dispersions of up to 50 µg using drop on demand (DOD) discharge experiments. The experiments were conducted with different combinations of process variables such as applied voltage, pneumatic pressure, and frequency.

Innovations in Materials Deposition for Plastic Electronics

  • Creagh, Linda T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.673-675
    • /
    • 2005
  • Ink jet printheads are now widely used in manufacturing processes that require precise dispensing of materials. Today, Dimatix manufactures a variety of drop-on-demand ink jet printheads for the industrial printing market, but emerging opportunities present fresh challenges to our technology. In response to requirements for digitally printing on flexible substrates and dispensing novel electronic fluids, we are developing next generation jetting technology based on our three-dimensional silicon MEMS technology with a piezo-driven pumping chamber integrated into the chip structure. This presentation will address the functional and physical design features and properties of Dimatix's MEMS process, its characteristics, reliability and usability. Examples of opportunities and applications for digitally printing electronic fluids on flexible substrates with MEMS-based ink jet technology will be presented.

  • PDF

A Study on the Composition of Silver Paste for Micro Nozzle Dispensing Method (미세노즐 토출에 적용 가능한 은 전극의 조성에 대한 연구)

  • Kim, Do-Hyung;Shin, Dong-Wook;Ryu, Sung-Soo;Chang, Hyo-Sik;Kim, Hyeong-Jun
    • New & Renewable Energy
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • The screen printing has been widely used to form silver electrodes in solar cell device due to their simplicity of process. However, the wavy and irregular surface which is believed to be originated from a screen mask mesh and thixotropic characteristics of paste on screen printing process is well-known to give a negative effect on solar cell efficiency. The dispensing method that the silver paste is extruded through micro nozzle under a moderate pressure and coated on substrate can form the silver electrode without any wavy surface. In this study, we optimize the composition of silver paste and develop paste blending condition based on the thixotropic behavior of paste. The optimized paste shows a large thixotropic loop area which is related to an aspect ratio of electrode line and has the viscosity of 40 $Pa{\cdot}s$ at 40 s-1. The electrode line we finally obtainis 67.2 ${\mu}m$ in width and has an aspect ratio of 0.277.

Measurement System for Phosphor Dispensing Shape of LED Chip Package Using Machine Vision (머신비전에 의한 LED Chip Package 형광물질 토출형상 측정)

  • Ha, Seok-Jae;Kim, Jong-Su;Cho, Myeong-Woo;Choi, Jong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2113-2120
    • /
    • 2013
  • In this study, an efficient machine vision based inspection system is developed for the in-line measurement of phosphor resin dispensing shapes on LED chip package. Since the phosphor resin (target material) has semitransparent characteristics, illuminated light beam is reflected from the bottom of the chip as well as from the surface. Since such phenomenon can deteriorate inspection reliability, a white LED and a 635nm laser slit beams are experimentally tested to decide suitable illumination optics. Also, specular and diffuse reflection methods are tested to decide suitable optical triangulation. As a result, it can be known that the combination of a white slit beam source and specular reflection method show the best inspection results. The Catmull-Rom spline interpolation is applied to the obtained data to form smoother surface. From the results, it can be conclude that the developed system can be sucessfully applied to the in-line inspection of LED chip packaging process.

Development of Drug Utilization Review Guidelines for Therapeutic Duplication of Antipyretics, Analgesics, and Anti-inflammatory Drugs Registered in Korea (국내 허가된 해열.진통.소염제의 치료중복 주의 가이드라인 개발)

  • Lee, Young-Sook;Kim, Nam-Hyo;Sohn, Hyun-Soon;Choi, Kyung-Eob;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.213-220
    • /
    • 2010
  • Therapeutic duplication (TD) is a serious problem that frequently occurring primarily in the ambulatory setting in Korea. Implementation of concurrent drug utilization review (DUR) is a promising way to reduce inappropriate prescription and dispensing, and improve patient safety. This study was aimed to develop the process of DUR module of TD. Sixty-five drug ingredients classified into the drug category of the antipyretic, analgesic, and anti-inflammatory drug approved in Korea (The KFDA-dess nated classification codes of 114 or 264) were reviewed for this purpose. The drug ingredients (and products) were reclassified based on WHO's Anatomical, Therapeutic and Chemical (ATC) classification system. The clinical practice guidelines, textbooks and product labels on therapeutic uses of these drugs in Korea and several fores n countries were reviewed. If the drugs were categorized into the same therapeutically duplicable class, they were defined not to be used concurrently because the concurrent use was "therapeutically duplicated (unnecessary or even harmful)". Among the studied drug products, the following 5 drug classes were considto beas "therapeutic duplication": (1), on-t tooid DURnti-inflammatory drugs (NSAIDs, including s Dicylates), (2),Anilidts, (3),Opioids, (4) Ergot Dk Doids and (5) 5-$HT_1$ receptor agonot s. Therefore, concurrent prescribing or dispensing of more than 2 drug ingredients any in the above same classes should be considered as TD and needed to be warrant for careful review by pharmacists before dispensing.