• Title/Summary/Keyword: Dislocations

Search Result 411, Processing Time 0.032 seconds

Microstructure and Mechanical Property of Irradiated Zr-2.5Nb Pressure Tube in Wolsong Unit-1

  • 김영숙;안상복;오동준;김성수;정용무
    • Transactions of Materials Processing
    • /
    • v.8 no.3
    • /
    • pp.241-241
    • /
    • 1999
  • With the aim of assessing the degradation of Zr-2.5Nb pressure tubes operating in the Wolsong unit-1 nuclear power plant, characterization tests are being conducted on irradiated Zr-2.5Nb tubes removed after 10-year operation. The examined tube had been exposed to temperatures ranging from 264 to 306℃ and a neutron fluence of 8.9×$10^{21}$ n/cm²(E>1 MeV) at the maximum. Tensile tests were carried out at temperatures ranging from RT to 300℃. The density of a-type and c-type dislocations was examined on the irradiated Zr-2.5Nb tube using a transmission electron microscope. Neutron irradiation up to 8.9×$10^{21}$ n/cm²(E>1 MeV) yielded an increase in a-type dislocation density of the Zr-2.5Nb pressure tube to 7.5×$10^{14} m^{-2}$, which was highest at the inlet of the tube exposed to the low temperature of 275℃. In contrast, the c-component dislocation density did not change with irradiation, keeping an initial dislocation density of 0.8×$10^{14} m^{-2}$ over the whole length of the tube. As expected, the neutron irradiation increased mechanical strength by about 17-26% in the transverse direction and by 34-39% in the longitudinal direction compared to that of the unirradiated tube at 300℃. The change in the mechanical properties with irradiation is discussed in association with the microstructural change as a function of temperature and neutron fluence.

A Chemically-driven Top-down Approach for the Formation of High Quality GaN Nanostructure with a Sharp Tip

  • Kim, Je-Hyeong;O, Chung-Seok;Go, Yeong-Ho;Go, Seok-Min;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.48-48
    • /
    • 2011
  • We have developed a chemically-driven top-down approach using vapor phase HCl to form various GaN nanostructures and successfully demonstrated dislocation-free and strain-relaxed GaN nanostructures without etching damage formed by a selective dissociation method. Our approach overcomes many limitations encountered in previous approaches. There is no need to make a pattern, complicated process, and expensive equipment, but it produces a high-quality nanostructure over a large area at low cost. As far as we know, this is the first time that various types of high-quality GaN nanostructures, such as dot, cone, and rod, could be formed by a chemical method without the use of a mask or pattern, especially on the Ga-polar GaN. It is well known that the Ga-polar GaN is difficult to etch by the common chemical wet etching method because of the chemical stability of GaN. Our chemically driven GaN nanostructures show excellent structure and optical properties. The formed nanostructure had various facets depending on the etching conditions and showed a high crystal quality due to the removal of defects, such as dislocations. These structure properties derived excellent optical performance of the GaN nanostructure. The GaN nanostructure had increased internal and external quantum efficiency due to increased light extraction, reduced strain, and improved crystal quality. The chemically driven GaN nanostructure shows promise in applications such as efficient light-emitting diodes, field emitters, and sensors.

  • PDF

Effect of Crystallographic Orientation on Fracture Mechanism of Ni-Base Superalloy

  • Han, Chang-Suk;Lim, Sang-Yeon
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.630-635
    • /
    • 2015
  • The fatigue strength of a nickel-base superalloy was studied. Stress-controlled fatigue tests were carried out at $700^{\circ}C$ and 5 Hz using triangular wave forms. In this study, two kinds of testing procedures were adopted. One is the conventional tension-zero fatigue test(R = 0). The other was a procedure in which the maximum stress was held at 1000 MPa and the minimum stress was diverse from zero to 1000 MPa at 24 and $700^{\circ}C$. The results of the fatigue tests at $700^{\circ}C$ indicate that the fracture mechanism changed according to both the mean stress and the stress range. At a higher stress range, ${\gamma}^{\prime}$ precipitates are sheared by a/2<110> dislocation pairs coupled by APB. Therefore, in a large stress range, the deformation occurred by shearing of ${\gamma}^{\prime}$ by a/2<110> dislocations, which brought about crystallographic shear fracture. As the stress range was decreased, the fracture mode gradually changed from crystallographic shear fracture to gradual growth of fatigue cracks. At an intermediate stress range, as it became more difficult for a/2<110> dislocation pairs to shear ${\gamma}^{\prime}$ particles, cracks started to propagate in the matrix, avoiding the harder ${\gamma}^{\prime}$ particles. High mean stress induced creep deformation, that is, ${\gamma}^{\prime}$ particles were sheared by {111}<112> slip systems, which led to the formation of stacking faults in the precipitates. Thus, the change in fracture mechanism brought about the inversion of the S-N curves.

Microstructure Observations in $(1-x)NdAlO_3-xCaTiO_3$ System ($(1-x)NdAlO_3-xCaTiO_3$ 시스템의 미세구조 관찰)

  • Lee, Hwack-Joo;Ryu, Hyun;Park, Hyun-Min;Cho, Yang-Koo;Kim, Jae-Chun;Nahm, Sahn
    • Applied Microscopy
    • /
    • v.32 no.1
    • /
    • pp.9-15
    • /
    • 2002
  • Microstructural investigations of $(1-x)NdAlO_3-xCaTiO_3$ (NACT) complex perovskite compounds were carried out using X-ray diffractometry, neutron diffraction and transmission electron microscopy. When $0.3{\leq}x{\leq}0.9$, NACT had not only the 1 : 1 chemical ordering of cations but also the antiphase and inphase tilting of oxygen octahedron and the antiparallel shift of cations. Both the antiphase boundaries and the ferroelastic domains were present in the microstructure. The long and straight ferroelastic domains became degenerate as x decreases. When x was smaller than 0.3, the chemical ordering was absent and the antiphase tilting of oxygen octahedron was observed. The defects like tangled dislocations and the second phase were also found in the microstructure.

The Influence of Vanadium Addition on Fracture Behavior and Martensite Substructure in a Ni-36.5at.%Al Alloy (Ni-36.5at.%Al 합금에서 V 첨가가 파괴거동 및 마르텐사이트 내부조직에 미치는 영향)

  • Kim, Young Do;Choi, Ju;Wayman, C. Marvin
    • Analytical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.203-211
    • /
    • 1992
  • Fracture behavior and martensite substructure of Ni-36.5at.%Al alloy were investigated with the addition of vanadium which is known as scavenging element of grain boundary. The fracture surfaces were examined by scanning electron microscopy and the EDX spectrometer was applied for composition analysis of fracture surfaces. The substructure of martensite was studied by transmission electron microscopy. By addition of vanadium, fracture surfaces show mixed modes of intergranular and transgranular fracture and more Al content is found on the grain boundaries. For Ni-36.5at.%Al alloy, the planar faults observed in the martensite plates are the internal twins. By increasing the vanadium content, the modulated structure with stacking faults and dislocations dominates while the twinned martensite disappears. The stacking fault is determined to be extrinsic due to the substitution of V for Al. It is concluded that the segregation of sulfur on the high-energy state stacking fault area suppresses the intergranular fracture.

  • PDF

Assessment of Capsular Insertion Type and of Capsular Elongation in Patients with Anterior Shoulder Instability and It's Correlation with Surgical Outcome: A Quantitative Assessment with Computed Tomography Arthrography

  • Kim, Do Hoon;Kim, Do Yeon;Choi, Hye Yeon;Park, Ji Soon;Lee, Ye Hyun;Oh, Joo Han
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.155-162
    • /
    • 2016
  • Background: The study aimed to determine the type of capsular insertion and the extent of capsular elongation in anterior shoulder instability by quantitatively evaluating their computed tomography arthrographic (CTA) findings, and to investigate the correlation of these parameters with surgical outcomes. Methods: We retrospectively reviewed 71 patients who underwent CTA and arthroscopic capsulolabral reconstruction for anterior shoulder instability between April 2004 and August 2008. The control group comprised 72 patients diagnosed as isolated type II superior labrum anterior to posterior (SLAP) lesion during the period. Among the 143 patients, 71 were examined with follow-up CTA at an average 13.8 months after surgery. It was measured the capsular length and cross-sectional area at two distinct capsular regions: the 4 and 5 o'clock position of the capsule. Results: With regards to the incidence of the type of anterior capsular insertion, type I was more common in the control group, whereas type III more common than in the instability group. Anterior capsular length and cross-sectional area were significantly greater in the instability group than in the control group. Among patients of the instability group, the number of dislocations and the presence of anterior labroligamentous periosteal sleeve avulsion lesion were significantly associated with anterior capsular redundancy. Postoperatively, recurrence was found in 3 patients (4.2%) and their postoperative capsular length and cross-sectional area were greater than those of patients without recurrence. Conclusions: Capsular insertion type and capsular redundancy derived through CTA may serve as important parameters for the management of anterior shoulder instability.

Treatment of Acute Acromioclavicular Joint Dislocation: Kirschner's Wire Trans-acromial Fixation versus AO Locking Hook Plate Fixation

  • Kim, Young-Jun;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.149-154
    • /
    • 2016
  • Background: The purpose of this study is to compare clinical and radiological outcomes between trans-acromial fixation with Kirschner's wire (K-wire) and AO locking hook plate fixation for acute acromioclavicular (AC) joint dislocation. Methods: This study included 61 patients who underwent either closed reduction and trans-acromial fixation with K-wire (group A, 23 patients) or open reduction and internal fixation with AO locking hook plate (group B, 38 patients). Pain on a visual analogue scale (VAS) score, the University of California Los Angeles (UCLA) shoulder score, the American Shoulder and Elbow Surgeons (ASES) score, and active range of motion (ROM) were used in the functional evaluation. For radiological evaluation, coracoclavicular distance (CCD) was measured on both clavicular anteroposterior view and compared between groups. Results: At one-year follow-up, no significant differences in VAS pain score, UCLA shoulder score, ASES score, and active ROM were observed between groups, despite five cases (22.7%, 5/23) of complication in group A. The side-to-side difference between normal and affected CCD was $2.4{\pm}2.2mm$ in group A and $0.2{\pm}0.7mm$ in group B. This difference showed a statistical significance between groups (p<0.001). Conclusions: For the treatment of acute AC joint dislocation, the K-wire trans-acromial fixation group showed a significantly greater CCD than the AO locking hook plate group. In addition, during the follow-up period, much higher incidence of complication related to implant was observed in the trans-acromial fixation group. Although clinical outcomes between groups were not significantly different, these results should be interpreted carefully.

Risk Factors for Recurrence of Anterior Shoulder Instability after Arthroscopic Surgery with Suture Anchors

  • Choi, Chang-Hyuk;Kim, Seok-Jun;Chae, Seung-Bum;Lee, Jae-Keun;Kim, Dong-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.78-83
    • /
    • 2016
  • Background: We investigated the risk factors for the recurrence of anterior shoulder instability after arthroscopic surgery with suture anchors and the clinical outcomes after reoperation. Methods: A total of 281 patients (February 2001 to December 2012) were enrolled into our study, and postoperative subluxation and dislocation were considered as recurrence of the condition. We analyzed radiologic results and functional outcome including the American Shoulder and Elbow Surgeons Evaluation Form, the Korean Shoulder Society Score, and the Rowe scores. Results: Of the 281 patients, instability recurred in 51 patients (18.1%). Sixteen out of 51 patients (31.4%) received a reoperation. In terms of the functional outcome, we found that the intact group, comprising patients without recurrence, had a significantly better functional outcome than those in the recurrent group. The size of glenoid defect at the time of initial surgery significantly differed between intact and recurrent group (p<0.05). We found that the number of dislocations, the time from the initial presentation of symptoms to surgery, and the number of anchor points significantly differed between initial operation and revision group (p<0.05). The functional outcome after revision surgery was comparable to intact group after initial operation. Conclusions: Eighteen percent of recurrence occurred after arthroscopic instability surgery, and 5.6% received reoperation surgery. Risk factors for recurrence was the initial size of glenoid defect. In cases of revision surgery, good clinical outcomes could be achieved using additional suture anchor.

The Fatigue Behavior of Mechanically Alloyed Al-4Mg Alloys Dispersed with Oxide Particles (기계적합금화된 분산형 Al-4Mg기 합금의 피로거동)

  • Pyun, J.W.;Cho, J.S.;Kwun, S.I.;Jo, Y.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.4
    • /
    • pp.237-242
    • /
    • 1993
  • The fatigue behaviors of mechanically alloyed Al-4Mg alloys dispersed with either $Al_2O_3$ or $MgAl_2O_4$ oxide particles were investigated. This study maily concerned with the role of coherency of dispersed particles with the matrix on the fatigue behavior of the alloys. The $MgAl_2O_4$ which has a spinel structure with the lattice parameter of exactly the twice of Al showed the habit relation with the matrix. The mechanically alloyed Al-4Mg alloys showed stable stress responses with fatigue cycles from start to failure regadless of strain amplitudes and of existence of dispersoids. The Al-4Mg alloy dispersed with $MgAl_2O_4$ showed not only the better static mechanical properties but also the better low cycle fatigue resistance than that with $Al_2O_3$, i.e., much higher plastic strain energy dissipated to failure, at low strain amplitude. However, this alloy showed inferior fatigue resistance to that dispersed with $Al_2O_3$ or that without dispersion at high strain amplitude. These results imply that $MgAl_2O_4$ may promote lowering the stacking fault energy of the alloy inherited from the coherency with the matrix so that dislocations shuttle back and forth on the same slip plane without cross slipping to other planes during fatigue at low strain amplitude resulting in long fatigue life.

  • PDF

SURGICAL TREATMENT OF RECURRENT TMJ DISLOCATION BY EMINECTOMY WITH DISCOPLASTY (하악관절융기 절제술과 악관절원판 성형술을 이용한 악관절 탈구의 외과적 치료)

  • Kim, Hyung-Gon;Choi, Hee-Soo;Huh, Jong-Ki;Park, Kwang-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.2
    • /
    • pp.141-146
    • /
    • 2002
  • Purpose: Various treatment methods have been utilized for recurrent dislocation of the TMJ (temporomandibular joint). The purpose of this study is to define the effect of the eminectomy with discoplasty that had been performed in patients with TMJ luxation. Materials and Methods: Twenty patients (22 joints), whose diagnosis were TMJ dislocation were selected in 772 patients (871 joints) who had been underwent TMJ surgery between 1988 and 2000. The selected patients were divided into two groups. Group I (12 joints) was the habitual-luxation group which involves the recurrent TMJ dislocation patients. Group II (10 joints) was the open lock-history group which involves the patients who had more than two episodes of TMJ luxation and TMJ disorders. The history of TMJ luxation, maximum mouth opening and other TMJ signs and symptoms before and after surgery were reviewed. Results: In group I, one patient who had been underwent both TMJ operation had a intermittent locking, but it disappeared after post-operative 32 months. In group II, intermittent pain was present in one patient who had bruxism, but it was disappeared by splint therapy. No more TMJ dislocations and other pains were checked in other patients of group I and II. Conclusion: Eminectomy with discoplasty may be used to successfully treat the TMJ habitual luxation accompanied with abnormal condition of the disc-condyle complex.