• Title/Summary/Keyword: Disinfection Process

검색결과 198건 처리시간 0.031초

Design and Implementation of Disinfection Service Platform based on MVC Pattern Using Web/App

  • Jang, Ye-jin;Jo, Yu-min;Shin, Ji-in;Jang, Yun-jeong;Jeong, Da-woon;Paik, Jong-ho
    • 인터넷정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.41-49
    • /
    • 2021
  • Due to the COVID-19 pandemic, issues related to quarantine are emerging. There are various infection prevention methods, but among them, it is certain to frequently disinfect the surface or the entire space of an object that has come into contact with the virus. However, the reality is that the number of times such disinfection is legally designated and the required number of personnel are very different depending on the building and facility. For this reason, there are no companies and systems that can professionally receive orders for disinfection work. In order to solve the aforementioned problems, this paper presents a method to design a disinfection service platform based on the MVC pattern, and implements the required functions based on this. Through this, it is possible to build a more systematic system, and it is hoped that it will be of great help to quarantine with an orderly process for disinfection work.

펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성 (Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp)

  • 안영석;양동진;채선하;임재림;이경혁
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.

태양광/광촉매를 이용한 오폐수 살균특성 (Disinfection Characteristic of Sewage Wastewater Treatment Using Solar Light/TiO2 Film System)

  • 조일형;이내현;안상우;김영규;이승목
    • 한국환경과학회지
    • /
    • 제15권7호
    • /
    • pp.677-688
    • /
    • 2006
  • Currently, the application of $TiO_2$ photocatalyst has been focused on purification and treatment of wastewater. However, the use of conventional $TiO_2$ slurry photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we studied that solar light/$TiO_2$ film system was designed and developed in order to examine disinfection characteristics of sewage wastewater treatment. The optimum conditions for disinfection such as solar light intensity, characteristic of sewage wastewater, amounts of $TiO_2$ and comparison of solar ligth/$TiO_2$ systems with UV light/$TiO_2$ system was examined. The results are as follows: (1) photocatalytic disinfection process with solar light in the presence of $TiO_2$ film more effectively killed total coliform (TC) than solar light or $TiO_2$ film absorption only. (2) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with remain resistant material. (3) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with the increase of amounts of $TiO_2$. (4) TC survival ratio decreased linearly with increasing UV light intensity. (5) The disinfection effect of solar light/$TiO_2$ slurry system decreased more than UV light/$TiO_2$ film systems. (6) The disinfection reaction followed first-order kinetics. We suggest that solar light instead of using artificial UV light was conducted to investigate the applicability of alternative energy source in the disinfection of TC and the degradation of organic material.

음용수의 전기분해 소독과정에서의 소독부산물 생성특성 (Characteristics of the Disinfection Byproducts Formation in Electrolysis Disinfection of Drinking Water)

  • 윤경애;박성빈;김영관
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.69-75
    • /
    • 2016
  • This study was conducted to examine the byproducts formation characteristics at the water treatment plants which applying electrolysis as a disinfection process in Gangwondo, Korea. Total of forty plants located in Gangwon Province, Korea were selected for the study. Correlation between dissolved organic carbon(DOC) and $SUVA_{254}$ was not clear. Among the species of the disinfection byproducts(DBPs), chlorate and trihalomethanes(THMs) accounted for 76% and 14% of DBPs, respectively. The effect of DOC or $SUVA_{254}$ on DBPs formation was not clearly demonstrated. The increased amount of THMs due to the raw water bromide content was found primarily in the form of chloroform, and the percent fraction of BDCM(bromodichloromethane) and DBCM(Dibromochloromethnae) was relatively insignificant. When the value of $SUVA_{254}$ was greater than $2L/mg{\cdot}m$, the percent fraction of BDCM and DBCM decreased while percent fraction of CF(chloroform) increased.

전기분해 염소소독공정의 반응표면분석법을 이용한 차아염소산나트륨 발생 최적화 (Application of Response Surface Methodology to Optimize the Performance of the Electro-Chlorination Process)

  • 주재현;박찬규
    • 한국환경보건학회지
    • /
    • 제48권3호
    • /
    • pp.167-175
    • /
    • 2022
  • Background: Disinfection is essential to provide drinking water from a water source. The disinfection process mainly consists of the use of chlorine and ozone, but when chlorine is used as a disinfectant, the problem of disinfection by-products arises. In order to resolve the issue of disinfection by-products, electro-chlorination technology that produces chlorine-based disinfectants from salt water through electrochemical principles should be applied. Objectives: This study surveys the possibility of optimally producing active chlorine from synthetic NaCl solutions using an electro-chlorination system through RSM. Methods: Response surface methodology (RSM) has been used for modeling and optimizing a variety of water and wastewater treatment processes. This study surveys the possibility of optimally producing active chlorine from synthetic saline solutions using electrolysis through RSM. Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. Results: Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. A central composite design (CCD) was applied to determine the optimal experimental factors for chlorine production. Conclusions: The concentration of the synthetic NaCl solution and the distance between electrodes had the greatest influence on the generation of hypochlorite disinfectant. The closer the distance between the electrodes and the higher the concentration of the synthetic NaCl solution, the more hypochlorous acid disinfectant was produced.

Box-Behnken법을 이용한 E. coli 소독에서 전기-UV-초음파 복합 공정의 최적화 (Optimization of Electro-UV-Ultrasonic Complex Process for E. coli Disinfection using Box-Behnken Experiment)

  • 김동석;박영식
    • 대한환경공학회지
    • /
    • 제33권3호
    • /
    • pp.149-156
    • /
    • 2011
  • 수중에서 E. coli 소독을 위한 전기-UV-초음파 복합 공정에 대해 실험계획법과 반응표면분석법(RSM)을 적용하였다. 2차반응표면 모형식을 추정할 수 있는 Box-Behnken법을 이용하여 전기-UV-초음파 복합 공정의 소독 반응에서 전기분해($X_1$), UV ($X_2$), 및 초음파 공정($X_3$)의 전력을 독립변수로 선정하여 수학적으로 모형화하였다. 소독 후 잔류 E. coli 수와 독립변수 사이의 실험에서 독립변수에 대해 다음의 모형식이 얻어졌다. 잔류 E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). 예측된 모형식은 실험 자료와 잘 일치하였다($R^2$ = 0.983). 2차원 등고선도와 3차원 반응표면도가 잔류 E. coli 수에 대한 최적 범위를 구하기 위하여 사용되었다. Design-Expert 소프트웨어의 '수치 최적화'를 이용하여 잔류 E. coli 수에 대한 최적 값을 찾은 결과 1.47 Ln CFU/L이었고, 최적 조건은 전기분해 6.94 W, UV 6.72 W 및 초음파 공정 14.23 W로 나타났다. 본 연구는 반응표면분석법이 복합 소독 공정에서 잔류 E. coli 수를 최소화하고 운전 조건을 최적화하기 위한 적절한 방법 중의 하나라는 것을 보여주었다.

회전식 부착 바실러스를 이용한 하수고도처리 공정에서의 총대장균군 제거 특성 (Removal Characteristics of Total Coliforms in a Rotating Activated Bacillus Contactor Process)

  • 김응호;조연제;박성주;신광수;임수빈;박현주
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.73-78
    • /
    • 2005
  • This study was performed to examine the disinfection capability of a Rotating Activated Bacillus Contactor (RABC) system, in which the predominant species, Bacillus sp. was expected to have a removal or inactivation effect of total coliforms. In a settling test with mixtures of E. coli and Bacillus sp., a high removal of E. coli was observed at $20{\sim}40^{\circ}C$, while insignificant removal at $10^{\circ}C$. In a batch test, a 4.5% addition of Bacillus sp. to activated sludge considerably enhanced the removal effect of total coliforms, indicating Bacillus sp. played an important role in improving the settlability of the sludge and coliforms. In a pilot scale RABC system, the concentration of total colifroms reduced remarkably in the settling tank, suggesting that total coliforms in the RABC process were eliminated through coagulation and precipitation, probably due to extracellular polymeric substance (EPS) of Bacillus sp. The fraction of Bacillus sp. in the total cell count in the RABC process was in the range of 4.5%~6.3%. The majority (75%) of the Bacillus sp. in the RABC process was Bacillus subtilis which is known to enhance coagulation and precipitation by producing EPS. Hence, an adoption of a RABC process might be able to eliminate the disinfection unit process from a wastewater treatment system.

플라즈마 공정을 이용한 고추역병균(Phytophthora capsici) 불활성화 모델의 적용 (Application of Inactivation Model on Phytophthora Blight Pathogen (Phytophthora capsici) using Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1393-1404
    • /
    • 2015
  • Ten empirical disinfection models for the plasma process were used to find an optimum model. The variation of model parameters in each model according to the operating conditions (first voltage, second voltage, air flow rate, pH, incubation water concentration) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Phytophthora capsici which cause wilt in tomato plantation. Optimum disinfection models were chosen among ten models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum models were shown as Log-linear+Tail model, Double Weibull model and Biphasic model. Three models were applied to the experimental data according to the variation of the operating conditions. In Log-linear+Tail model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$ and $k_{max}$ values were examined. In Double Weibull model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$, ${\alpha}$, ${\delta}_1$, ${\delta}_2$, p values were calculated and examined. In Biphasic model, $Log_{10}(N_o)$, f, $k_{max1}$ and $k_{max2}$ values were used. The appropriate model parameters for the calculation of optimum operating conditions were $k_{max}$, ${\alpha}$, $k_{max1}$ at each model, respectively.

FUE 공정에 의한 Ballast Water처리 (Treatment of Ballast Water By Filtration -Ultraviolet radiation-Electrolytic Process)

  • 박상호;김억조;박성진;김인수
    • 해양환경안전학회지
    • /
    • 제8권2호
    • /
    • pp.23-27
    • /
    • 2002
  • Reballasting at sea, as recommended by the IMO guidelines, currently provides the best-available measure to reduce the risk of transfer of harmful aquatic organisms, but is subject to serious ship-safety limits. It is therefore extremely important that alternative, effective ballast water management and treatment methods are developed as soon as possible, to replace reballasting at sea. Filtration-Ultraviolet radiation-Electrolytic process (FUE) was evaluated for disinfection of seawater used In ballast water Optimal current density and UV light intensity were 2.0A/dm$^2$ and, 220㎼/$\textrm{cm}^2$/m with which 100% reduction time was 2sec in a Ultraviolet radiation-Electrolytic process. This study showed that FUE process was effective for the disinfection of commonly isolated bacteria and bacillus from ballast water.

  • PDF

Effect of $H_2O_2$ and Metals on The Sonochemical Decomposition of Humic Substances in Wastewater Effluent

  • Jung, Oh-Jun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제10권S_3호
    • /
    • pp.127-137
    • /
    • 2001
  • The sonochemical Process has been applied as a treatment method and was investigated its effect on the decomposition of humic substances(HS). The reaction kinetics and mechanisms in the Process of sonochemical treatment for humic substances(HS) in wastewater have also been discussed. It was observed that the metal ions such as Fe(II) and Mn(II) showed catalytic effects, while Al(III), Ca(II), and Mg(II) had inhibitory effects on the decomposition of humic substances in sonochemical reaction with hydrogen peroxide. Experimental results also showed factors such as hydrogen peroxide dose affected the formation of disinfection by-products. Two trihalomethanes, chloroform and dichlorobromomethane were formed as major disinfection by-products during chlorination. The mechanism of radical reaction is controlled by an oxidation process. The radicals are so reactive that most of them are consumed by HS radicals and hydroxyl radicals can be acted on organic solutes by hydroxyl addition, hydrogen abstraction, and electron transfer. The depolymerization and the radical reaction of HS radicals appear to occur simultaneously. The final steps of the reaction are the conversion of organic acids to carbon dioxide.

  • PDF