• 제목/요약/키워드: Disinfection Process

검색결과 205건 처리시간 0.024초

상온대기압 질소 및 공기 플라즈마가 의치상용 레진의 표면 특성과 살균효과에 미치는 영향 (Effect of non-thermal atmospheric pressure nitrogen and air plasma on the surface properties and the disinfection of denture base resin)

  • 서혜연;유은미;최유리;김수화;김광만;김경남
    • 한국치위생학회지
    • /
    • 제14권5호
    • /
    • pp.783-788
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the effect of non-thermal atmospheric pressure plasma jet(NTAPPJ) on surface properties and Streptococcus mutans disinfection of denture base resin. Methods : Self-cured denture base resin (Jet denture repair resin, Lang dental Mfg, co., USA) was used to make specimen($12mm{\times}2mm$). To observe surface change before and after plasma process, surface roughness and contact angle were measured. For sterilization experiments, the surfaces of specimens were treated with nitrogen and air NTAPPJ for 1 minute after S. mutans was inoculated on the material surfaces. Results : Before plasma process, surface roughness of denture base resin was $0.21{\mu}m{\pm}0.02{\mu}m$. After air and nitrogen NTAPPJ process, surface roughness was $0.19{\mu}m{\pm}0.03{\mu}m$ and $0.18{\mu}m{\pm}0.01{\mu}m$ respectively. There was no significant difference(p>0.05). Contact angle of control group without plasma process was $83.81^{\circ}{\pm}3.14^{\circ}$, while after plasma treatment, contact angles of air NTAPPJ and nitrogen NTAPPJ groups were $63.29^{\circ}{\pm}2.27^{\circ}$ and $46.68^{\circ}{\pm}5.82^{\circ}$ respectively. The result showed a significant decrease in contact angle after plasma process(p<0.05). Compared to the control group 6020.33(CFU/mL) without plasma process, CFU decreased significantly after air NTAPPJ 90.75(CFU/mL) and nitrogen NTAPPJ 80.25(CFU/mL) treatment(p<0.05). Conclusions : It was considered that NTAPPJ can be used for denture disinfection without changing surface properties of materials.

대전 일부 지역 치과종사자의 화학소독제에 관한 지식도 연구 (Knowledge on the chemical disinfectants among dental workers in some Daejeon region)

  • 민희홍;안권숙
    • 한국치위생학회지
    • /
    • 제7권4호
    • /
    • pp.455-470
    • /
    • 2007
  • The usage of appropriate disinfectants is essential for infection control in dental hospitals, dental clinics. Inadequate use of disinfectants is the cause of human or environmental toxicity and is a waste of cost. This study was aimed to assess the level of knowledge on the disinfection and chemical disinfectants among dental workers in dental hospitals, dental clinics. It's ultimately intended to serve as a basis for the preparation of more effective, appropriate educational programs on the disinfection and manuals on the use of disinfectants for dental workers. This study enforced a questionnaire with 184 dental workers employed in dental hospitals, dental clinics from 15 Aug. to 15 Sep. 2007, in the area of Daejeon. The obtained result were as follows; 1. The population sociological feature of dental hospital and dental clinic showed that significant differences of dental service career(pM0.039). Dental service career of dental workers shows; below 3 years 42.9%, 4~6 years 34.7%, more than 7 years 22.4% in dental hospitals, below 3 years 30.4%, 4~6 years 26.7%, more than 7 years 43.0% in dental clinics(pM0.039). 2. The average score of dental workers knowledge in 'Critical item soaks in high-level disinfectants for 20minutes was 2.73V0.49 point, got from knowledge of dental instrument is appropriate to immerse before sterilization in the dental device disinfection(pM0.002). 3. In the general disinfection which it follows in education experience of chemical disinfectants direction for use, 'Direction for use by Spaulding process classification' responded that the correct answer was the education experience dental workers 60.0%, the education non-experience dental workers 39.5%(p=0.026). 4. In the dental device disinfection which it follows in education experience of chemical disinfectants direction for use. 'High level disinfection is not applied for the non-critical items and equipment' responded that the education experience dental workers 49.2%, the education non-experience dental workers 31.9%(pM0.045), 'Semi-critical items is applied same method in presence of the infection disease which it acts responded that the education experience dental workers 44.6% answer back, the education non-experience dental workers 24.4%(pM0.017). 5. 'A hand disinfectants of anticeptics have effect' the education experience dental workers 78.5% answer back, the education non-experience dental workers 52.9%(pM0.003). 1t uses with hand disinfectants when the instruments which be imbrued and patient contact', the education experience dental workers 78.5% answer back, the education non-experience dental workers 62.2%(pM0.026), 'Boric acid solution uses for the skin disinfectants the education experience dental workers 52.3% answer back, the education non-experience dental workers is 37.0%(pM0.016), 'Gluconate have effective difference which it follows in chemical disinfectant consistency and the solution type' education experience dental workers 72.3% answer back, education non-experience dental workers 47.9%(pM0.004). 6. The education experience dental workers were appeared higher than the education non-experience dental workers in knowledge of the disinfection and chemical disinfectants. Consequently system and the specialty education which is standardized continuously must be provided to all dental workers.

  • PDF

양식장 넙치 폐사어를 이용한 단백질 소재의 개발에 관한 연구(2) -산업화공정 연구- (A Study on Development of Protein Materials using Dead Flatfish from Fish Farms(2) -Industrial Process-)

  • 강건희;이민규;감상규;정갑섭
    • 한국환경과학회지
    • /
    • 제22권12호
    • /
    • pp.1625-1631
    • /
    • 2013
  • In manufacturing of flatfish skin collagen peptide (FSCP) and flatfish protein hydrolysate (FPH) by reuse of dead flatfish from fish farm in Jeju island, the industrial process was optimized with the laboratory scale research and the on-field process. Segmented unit processes from raw material incoming to shipment were established to produce commercial product of FSCP and FPH. Total plate counts of FSCP were twenty five times of FPH, but food poisoning bacteria were not detected in two samples. FSCP and FPH were safe from heavy metal such as Pb(II), Cd(II) and Hg(II). The residual contents of antibiotics and disinfection matter in FSCP and FPH were not detected. The optimized process for mass production made the one-third of the running time and two times of the yield. From economic analysis, the production cost was estimated to 22,000 and 12,000 won/kg for FSCP and FPH, respectively. Therefore the product from the reuse of dead flatfish was expected to have a considerable competitive price and high added-value functional food material compared with other commercially available fish products.

Ozone과 UV를 이용한 Cryptosporidium의 불활성화 효과 (Inactivation Effect of Cryptosporidium by Ozone and UV)

  • 김윤희;이철희;이순화
    • 대한환경공학회지
    • /
    • 제29권1호
    • /
    • pp.31-39
    • /
    • 2007
  • 본 연구에서는 오존 및 UV 소독을 통해 Cryptosporidium 불활성화 특성을 파악하고 소독의 방향성을 제시하고자 하였다. ozone을 이용한 Cryptosporidium 불활성화 효과는 소독지표의 하나인 CT값$(mg{\cdot}min/L)$으로 평가할 수 있으며, 1 log(90%) 불활성화 CT값은 5.77 $mg{\cdot}min/L$이고 2 log(99%) 불화성화 CT값은 21.30 $mg{\cdot}min/L$인 것으로 나타났다. UV 소독을 통한 Cryptosporidium oocysts 불활성화 효과의 경우 pH(5, 7, 9)와 저탁도(5 NTU 이하) 그리고 UV 강도(0.2, 0.6 $mWs/cm^2$)에 따른 효과는 뚜렷하게 나타나지 않았다. 그러나 20 NTU 이상의 고탁도인 경우에는 불활성 효과가 뚜렷하게 감소하였다. 따라서 정수처리공정에서 UV 소독을 실시할 경우 탁도를 충분히 낮춰야만 만족할 만한 소독 능을 얻을 수 있으며 높은 UV 강도에서 충분한 시간 동안 UV가 조사된다면 더 높은 Cryptosporidium oocysts의 불활성화 효과를 얻을 수 있을 것으로 사료된다.

실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측 (Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments)

  • 조민;정현미;김이호;손진식;박상정;윤제용
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

정수장 현장제조염소의 브로메이트와 클로레이트의 생성 특성연구 (Study on disinfection by-products formation according to kind of salt in on-site production)

  • 민병대;정현미;김태욱;박주현
    • 상하수도학회지
    • /
    • 제29권5호
    • /
    • pp.575-581
    • /
    • 2015
  • Although disinfection in drinking water treatment plants provides a safer water supply by inactivating pathogenic microorganisms, harmful disinfection by-products may be formed. In this study, the disinfectant, chlorine, was produced on-site from the electrolysis of salt (NaCl), and the by-products of the disinfection process, bromate and chlorate, were analyzed. The provisional guideline levels for bromate and chlorate in drinking water are $10{\mu}g/L$ and $700{\mu}g/L$, in Korea, respectively. Bromide salt was detected at concentrations ranging from 6.0 ~ 622 mg/kg. Bromate and chlorate were detected at concentrations ranging from non-detect (ND) ~ 45.3mg/L and 40.5 ~ 1,202 mg/L, respectively. When comparing the bromide concentration in the salt to the bromate concentration in the chlorine produced by salt electrolysis, the correlation of bromide to bromate concentration was 0.870 (active chlorine concentration from on-site production: 0.6-0.8%, n=40). The correlation of bromate concentration in the chlorine produced to that in the treated water was 0.866.

Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis

  • Shivanand Bomman;Munish Ashat;Navroop Nagra;Mahendran Jayaraj;Shruti Chandra;Richard A Kozarek;Andrew Ross;Rajesh Krishnamoorthi
    • Clinical Endoscopy
    • /
    • 제55권1호
    • /
    • pp.33-40
    • /
    • 2022
  • Background/Aims: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. Methods: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. Results: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%-10.8%, inconsistency index [I2]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%-2.7%, I2=94.96). Conclusions: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted.

오존접촉조 설계를 위한 소독 기준 (Ozone disinfection criteria for contactor design)

  • DumeauC;BoisdonV
    • 수도
    • /
    • 제24권6호통권87호
    • /
    • pp.23-31
    • /
    • 1997
  • Ozonation is an effective process in providing microbiologically safe drinking water. The operation of the ozonation stage is often based on disinfection criteria which include security factors, such as the CT criterion. This type of ozonation management, which mat include large safety margins, will no longer be possible, since formation of ozonation byproducts has to be avoided. In order to reduce the security factor, a computerized tool to predict with more accuracy inactivation of micro-organisms in the ozonation process has been developed.

  • PDF

Pt/Ti 격자형 평판 전극을 이용한 혼합 산화제 생성 및 E. coli 불활성화 (Formation of Mixed Oxidants and Inactivation of E. coil by the Electrochemical Process using a Grid Shape Pt/Ti Electrode)

  • 정연정;오병수;박상연;백고운;강준원
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.851-855
    • /
    • 2006
  • The aim of this study was to investigate characteristics of formation of mixed oxidants and some aspects of the performance of electrochemical process as an alternative disinfection strategy for water purification. The study of electrochemical process has shown free chlorine to be produced, but smaller amounts of stronger oxidants, such as ozone, hydrogen peroxide and OH radicals, were also generated. The formation of ozone and hydrogen peroxide increased with increasing electric conductivity, but was limited at conductivities greater than 0.6 mS/cm. Also, formation of OH radical was enhanced as electric conductivity was increased to 0.9 mS/cm and The stead-state concentrations of OH radical were calculated at $1.1{\sim}6.4{\times}10^{-14}M$. Using E. coti, inactivation kinetic studies were performed. With the exception of free chlorine, the role of mixed oxidants, especially OH radical, was investigated for enhancement of the inactivation rate.

정수처리 공정에서 모델 물질들을 이용한 천연유기물질 처리능 및 소독부산물 생성능 평가 (Evaluation of Natural Organic Matter Treatability and Disinfection By-Products Formation Potential using Model Compounds)

  • 손희종;정종문;최진택;손형식;장성호
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1153-1160
    • /
    • 2013
  • While a range of natural organic matter (NOM) types can generate high levels of disinfection by-products (DBPs) after chlorination, there is little understanding of which specific compounds act as precursors. Use of eight model compounds allows linking of explicit properties to treatability and DBP formation potential (DBPFP). The removal of model compounds by various treatment processes and their haloacetic acid formation potential (HAAFP) before and after treatment were recorded. The model compounds comprised a range of hydrophobic (HPO) and hydrophilic (HPI) neutral and anionic compounds. On the treatment processes, an ozone oxidation process was moderate for control of model compounds, while the HPO-neutral compound was most treatable with activated carbon process. Biodegradation was successful in removing amino acids, while coagulation and ion exchange process had little effect on neutral molecules. Although compared with the HPO compounds the HPI compounds had low HAAFP the ozone oxidation and biodegradation were capable of increasing their HAAFP. In situations where neutral or HPI molecules have high DBPFP additional treatments may be required to remove recalcitrant NOM and control DBPs.