• Title/Summary/Keyword: Disinfection Effect

Search Result 241, Processing Time 0.029 seconds

Effect of Disinfection Process Combination on E. coli Deactivation and Oxidants Generation (E. coli 불활성화와 산화제 생성에 미치는 소독 공정 결합의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.891-898
    • /
    • 2011
  • The aim of this research was to evaluate the effect of combination of disinfection process (electrolysis, UV process) on Escherichia coli (E. coli) disinfection and oxidants (OH radical, $ClO_2$, HOCl, $H_2O_2$ and $O_3$) generation. The effect of electrolyte type (NaCl, KCl and $Na_2SO_4$) on the E. coli disinfection and oxidants generation were evaluated. The experimental results showed that performance of E. coli disinfection of electrolysis and UV single process was similar. Combination of electrolysis and UV process enhanced the E. coli disinfection and 4-carboxybenzaldehyde (4-CBA, indicator of the generation of OH radical) degradation. It is clearly showed synergy effect on disinfection and OH radical formation. However chlorine ($ClO_2$, HOCl) and oxygen type ($H_2O_2$, $O_3$) oxidants were decreased with the combination of two process. In electrolysis + UV complex process, electro-generated $H_2O_2$ and $O_3$ were reacted with UV light of UV-C lamp and increased 4-CBA degradation(increase OH radical). Disinfection of electrolyte of chlorine type was higher than that of the sulfate type electrolyte due to the higher generation of OH radical and oxidants.

Effect of Water Quality of Artificial Sewage on E. coli Disinfection Using Electrolysis Process (전기분해 공정을 이용한 E. coli 소독에 미치는 인공하수 수질의 영향)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1115-1124
    • /
    • 2011
  • There is an increasing incidence in health problems related to environmental issues that originate from inadequate treatment of sewage. This has compelled scientists to engage in innovative technologies to achieve a effective disinfection process. Electrolysis has emerged as one of the more feasible alternatives to conventional disinfection process. The objectives of the present paper were to investigate the effect of chemical characteristics on oxidant formation and Escherichia coli (E. coli) disinfection in synthetic sewage effluents. The influence of parameters such as COD, SS, T-N and T-P were investigated using laboratory scale batch reactor. The results showed that the higher COD, T-N and T-P concentration, the lower N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) degradation and E. coli disinfection was observed. The order of effect of RNO degradation and E. coli disinfection was T-P > COD > T-N > SS. When 4 parameter of water quality were worked simultaneously, oxidants formation and disinfection was decreased with increase of the concentration of sewage. To increase of the disinfection performance, the increase of disinfection time or electric power was need.

A Study on the Microorganism Disinfection and Characteristics of Discharged Water of Dielectric Barrier Discharge Plasma Systems (유전체 장벽 방전 플라즈마 방전수의 특성과 미생물 소독에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.159-165
    • /
    • 2012
  • Objectives: This experiment was carried out to elucidate the effect of discharged water on the disinfection of $Phytophthora$ $capsici$ and evaluate the water characteristics. Methods: The dielectric barrier discharges (DBD) plasma reactor system used in this study consisted of a plasma component [discharge, ground electrode and quartz dielectric tube], high voltage source, and air supply. The effects of water characteristics such as pH, ORP and conductivity and the disinfection effect of discharged water were investigated. Results: Experimental results showed that in the process of discharge, the pH decreased, whereas ORP and electric conductivity increased. When the discharge time was 30 min, $Phytophthora$ $capsici$ of 2.94 log was disinfected within 300 seconds. Disinfection performance of stored discharged water was maintained for three days; however the disinfection effect vanished after five days. When $Phytophthora$ $capsici$ was injected into the discharged water, the disinfection effect decreased after two days. Conclusions: It is considered that the main disinfection parameters of the discharged water were chemically active species such as $H_2O_2$ and $O_3$ and high ORP.

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier (초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구)

  • Kim, Seunga;Kim, Jihyun;Lee, Minjoo;Kim, Jayun;Jung, Woosik;Park, Joonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

Inactivation of Legionella pneumophila by Electrochemical Disinfection (전기화학적 소독에 의한 Legionella pneumophila 불활성화)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.613-619
    • /
    • 2007
  • This study has carried out a performance of dimensionally stable anode for the purpose of disinfection of Legionella pneumophila in water. Three kinds of electrode were prepared by plating and thermal deposition, which were coated by the oxides of Pt, Ru and Ir on Ti metal surface, respectively. The order of disinfection performance for Legionella pneumophila was Ru/Ti > Ir/Ti > Pt/Ti. Free Cl and $ClO_2$ generation of Ir/Ti electrode was higher than that of two electrodes. However, the concentrations of generated $H_2O_2$ and $O_3$ of the Ru/Ti electrode were highest among the three electrodes. The higher NaCl concentration was, the more oxidants was generated and disinfection effect was increased. However, optimum NaCl dosage was 0.0125% due to the regulation on the conductivity and $Cl^-$ concentration for the cooling water quality of air conditioning and refrigeration equipment. With the increase of current, oxidants was more generated and following disinfection effect was increased. The increase of electrode distance reduced oxidants generation due to the low electric power, and their disinfection effect was decreased accordingly.

Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water (전기분해수 살균효과 및 소독부산물 생성 특성 평가)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System (소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

Inactivation of E. coli by Electrolysis+UV Process (전기+UV 공정에 의한 E. coli 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.667-673
    • /
    • 2009
  • This study has carried out to evaluate the performance of single (electrolysis, UV and ultrasonic process) and complex process (Electrolysis+UV, UV+Ultrasonic and Electrolysis+Ultrasonic) for the purpose of disinfection of Escherichia coli in water. The order of disinfection performance for E. coli in single process lie in: Electrolysis ${\fallingdotseq}$ UV >> ultrasonic process. OH radical was not produced in single disinfection process. Among the three kinds of complex process, disinfection performance of the Electrolysis+UV was higher than that of the other process (UV+Ultrasonic and Electrolysis+Ultrasonic). It demonstrated a synergetic effect between the UV and electrolysis. When the use of $Na_2SO_4$ as electrolyte instead of NaCl, current increase or more reaction time was needed for the complete disinfection. The disinfection performance of pre-electrolysis (20 W, 30sec) and post-UV (10 W, 30 sec) was higher than that of the simultaneous electrolysis+UV process at same electric power (30 W, 30 second).

A Study on the UV Intensity Models and their Affecting Factors (자외선 강도 산정 모델과 영향 인자에 관한 연구)

  • Kim, Dooil;Choi, Younggyun;Kim, Sunghong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.421-427
    • /
    • 2008
  • UV disinfection is widely used in water treatment facilities and wastewater treatment plant because of its effectiveness to removal of pathogen and Giardia which is resistant to traditional chemical disinfection. As a design and performance tool of UV disinfection system, 3 dimensional UV intensity models were composed and simulated to compare each other and to find affecting factors in this study. Reflection, refraction and absorption are important parameters in UV intensity model and MPSS and MSSS model can reflect these parameters while LSI model can not. Absorption is the most important parameters among the reflection, refraction, absorption and shadowing so, this should not be neglect. Based on this simulation, shadowing effect is negligible when the number of installed lamp is a few but, this effect can not be neglectable when the number of installed lamp is quite a few. The errors according to shadowing effect is increased as the number of lamp installed increased.

Evaluation of Environmental Contamination and Disinfection Effects in Patient Rooms with Carbapenem-Resistant Enterobacteriaceae Using ATP Measurements and Microbial Cultures (ATP 측정과 미생물 배양검사를 이용한 카바페넴내성장내세균 보유환자 병실 환경 오염 및 환경 소독 효과 평가)

  • Kim, Ji Eun;Jeong, Jae Sim;Kim, Mi Na;Park, Eun Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.339-346
    • /
    • 2021
  • Purpose: To determine the extent of environmental contamination and the effect of disinfection around patients with carbapenem-resistant Enterobacteriaceae (CRE) using adenosine triphosphate (ATP) measurements and microbial culture tests. Methods: The subjects of this study were 10 patients hospitalized in a single room due to CRE from April 13 to 21, 2021. One hundred and sixty samples were collected using cotton swabs from the patients' environment including the surface and drain of sinks and toilet seats before and after disinfection of the room after discharge. Twenty-one samples were collected from the nurses' personal digital assistants (PDAs), keyboards, and computer mice before disinfection. The relative light units (RLUs) and CRE colony-forming units (CFU) of 181 samples were measured using ATP test equipment and chrome agar plates, respectively. Results: The highest RLUs were measured at the sink drains before and after disinfection. Four CRE samples from the sink drains (2), sink surface (1), and toilet bowl (1) before disinfection were cultured. Based on the failure criteria (≥ 250 RLU/cm2 and ≥ 1 CFU/100 cm2), 90 % and 50 % of the samples from the drain exceeded the failure criteria before and after disinfection, respectively. In the culture tests, CRE was not detected after disinfection. Conclusion: According to the RLU and CFU measurements of drain samples, disinfection was not effective. Thus, improvements in the disinfection methods of drains, as well as more efficient and systematic environmental decontamination and disinfection evaluation tools, are needed to accurately evaluate the effectiveness of disinfection in various places.