• 제목/요약/키워드: Discrete PI Control

검색결과 25건 처리시간 0.019초

Oven Temperature Control by Integral - Cycle Binary Rate Modulation Technique

  • Tipsuwanporn, V.;Piyarat, W.;Chochai, N.;Jamjan, K.;Paraken, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.278-280
    • /
    • 1999
  • This paper proposes controlling of temperature in an oven by using 4 bits Integral - Cycle Binary Rate Modulation (IBRM) method and ac line with frequency 50 Hz. Microcontroller MCS-51 controls IBRM according to Proportional Integral controller (PI) function. Discrete signals are used in the system modeled by using Ziegler Nichols principle for analyzing the stability before designing the system. This procedure makes it easy to investigate system response. The system is implemented by 4 bits digital circuit which gives 320 patterns of ac signal fur controlling the generation of energy for 3,000 watts thermal coil every 20 ms of each cycle. We divide scan time (Ts$\sub$n/) in to 20 intervals, 1 ms interval is selected to generate 16 patterns IBRM. Because of this method gives the ripple lower than 2% it generates less noise fur system. Moreover, we can consider whole system from the time model of control procedure and IBRM algorithm at 40-200$^{\circ}C$ with ${\pm}$ 1$^{\circ}C$ error in the 1 cubic meter oven.

  • PDF

Affine Projection 알고리즘을 이용한 표면 부착형 영구자석 전동기의 온라인 파라미터 추정 (Online Parameter Estimation of SPMSM using Affine Projection Algorithm)

  • 문병훈;김형우;최준영
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.66-71
    • /
    • 2018
  • We propose an online parameter estimation method for surface-mounted permanent-magnet synchronous motor (SPMSM) using an affine projection algorithm (APA). The proposed method estimates parameters with two APAs based on the discrete-time model equation of SPMSM during motor operation. The first APA is designed to estimate inductance, and the second APA is designed to estimate resistance and flux linkage. However, in case when the d-axis current is controlled to 0A, the second APA cannot estimate resistance and flux linkage simultaneously because the matrix rank in APA becomes deficient. To overcome this problem, we temporarily inject a negative reference current input to the d-axis control loop, and the matrix in the APA then becomes full rank, which enables the simultaneous estimation of resistance and flux linkage. The proposed method is verified by PSIM simulation and an actual experiment, and the results reveal that SPMSM parameters can be estimated online during motor operation.

새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구 (A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator)

  • 곽아림;박성미;손경종;박성준;김종철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Real-Time HIL Simulation of the Discontinuous Conduction Mode in Voltage Source PWM Power Converters

  • Futo, Andras;Kokenyesi, Tamas;Varjasi, Istvan;Suto, Zoltan;Vajk, Istvan;Balogh, Attila;Balazs, Gergely Gyorgy
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1535-1544
    • /
    • 2017
  • Advances in FPGA technology have enabled fast real-time simulation of power converters, filters and loads. FPGA based HIL (Hardware-In-the-Loop) simulators have revolutionized control hardware and software development for power electronics. Common time step sizes in the order of 100ns are sufficient for simulating switching frequency current and voltage ripples. In order to keep the time step as small as possible, ideal switching function models are often used to simulate the phase legs. This often produces inferior results when simulating the discontinuous conduction mode (DCM) and disabled operational states. Therefore, the corresponding measurement and protection units cannot be tested properly. This paper describes a new solution for this problem utilizing a discrete-time PI controller. The PI controller simulates the proper DC and low frequency AC components of the phase leg voltage during disabled operation. It also retains the advantage of fast real-time execution of switch-based models when an accurate simulation of high frequency junction capacitor oscillations is not necessary.

Periodontal inflamed surface area as a novel numerical variable describing periodontal conditions

  • Park, Shin-Young;Ahn, Soyeon;Lee, Jung-Tae;Yun, Pil-Young;Lee, Yun Jong;Lee, Joo Youn;Song, Yeong Wook;Chang, Yoon-Seok;Lee, Hyo-Jung
    • Journal of Periodontal and Implant Science
    • /
    • 제47권5호
    • /
    • pp.328-338
    • /
    • 2017
  • Purpose: Chronic periodontitis is an inflammatory disease induced by pathogenic bacterial accumulation. A novel index, the periodontal inflamed surface area (PISA), represents the sum of the periodontal pocket depth of bleeding on probing (BOP)-positive sites. It is advantageous for data processing and analysis because it can be treated as a continuous variable to quantify periodontal inflammation. In the present study, we evaluated correlations between PISA and periodontal classifications, and examined PISA as an index integrating the discrete conventional periodontal indexes. Methods: This study was a cross-sectional subgroup analysis of data from a prospective cohort study investigating the association between chronic periodontitis and the clinical features of ankylosing spondylitis. Data from 84 patients without systemic diseases (the control group in the previous study) were analyzed in the present study. Results: PISA values were positively correlated with conventional periodontal classifications (Spearman correlation coefficient=0.52; P<0.01) and with periodontal indexes, such as BOP and the plaque index (PI) (r=0.94; P<0.01 and r=0.60; P<0.01, respectively; Pearson correlation test). Porphyromonas gingivalis expression and the presence of serum P. gingivalis antibodies were significant factors affecting PISA values in a simple linear regression analysis, together with periodontal classification, PI, bleeding index, and smoking, but not in the multivariate analysis. In the multivariate linear regression analysis, PISA values were positively correlated with the quantity of current smoking, PI, and severity of periodontal disease. Conclusions: PISA integrates multiple periodontal indexes, such as probing pocket depth, BOP, and PI into a numerical variable. PISA is advantageous for quantifying periodontal inflammation and plaque accumulation.