• 제목/요약/키워드: Discontinuous Current Mode

검색결과 143건 처리시간 0.035초

이산 시간 영역 해석에 기반한 벅 AC/DC LED 구동기의 슬로프 보상 설계 (Slope Compensation Design of Buck AC/DC LED Driver Based on Discrete-Time Domain Analysis)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.207-214
    • /
    • 2019
  • In this study, discrete-time domain analysis is proposed to investigate the input current of a buck AC/DC light-emitting diode (LED) driver. The buck power factor correction converter can operate in both discontinuous conduction mode (DCM) and continuous conduction mode (CCM). Two discontinuous and two continuous conduction operating modes are possible depending on which event terminates the conduction of the main switch in a switching cycle. All four operating modes are considered in the discrete-time domain analysis. The peak current-mode control with slope compensation is used to design a low-cost AC/DC LED driver. A slope compensation design of the buck AC/DC LED driver is described on the basis of a discrete-time domain analysis. Experimental results are presented to confirm the usefulness of the proposed analysis.

PV-AC 모듈형 단상 플라이백 인버터의 출력 전류 품질 보정을 위한 디지털 스위칭 제어기법 (Digital Switching Control Method for Current shaping of Single Phase Flyback Inverter for Photovoltaic AC Modules)

  • 노용수;임승범;지용혁;정두용;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.47-48
    • /
    • 2012
  • In generally, grid connected single-phase flyback inverter is operated as boundary or discontinuous conduction mode. However, the flyback inverter can be operated in continuous conduction mode (CCM) due to its operating conditions in spite of it is designed to operate under boundary or discontinuous conduction mode. This situation causes unintended distortion to output current. In this paper, a current shaping method on unfolding bridge to reduce the output current distortion.

  • PDF

불연속 전류모드에서의 다상 교호 강압컨버터의 특성 해석 (Characteristic Analysis of Multi-Phase Interleaved Buck Converter in Discontinuous Inductor Current Mode)

  • 장은승;신휘범
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.123-130
    • /
    • 2007
  • 본 논문에서는 불연속 인덕터 전류모드에서의 다상 교호 강압 컨버터의 정상상태 해석 및 소신호 모델을 유도하여 일반화된 식을 제시한다. 컨버터의 제어기 설계를 위해서 필요한 완전한 차수 모델을 통한 소신호 모델의 전달함수를 유도하고 이를 통해 시스템의 동특성을 분석한다. 시뮬레이션 및 실험 결과를 통하여 이론에서 제시한 특성을 검증한다.

새로운 무손실 스너버를 이용한 부분공진형 고효율 $3\phi$ AC-DC 부스터 컨버터 (A New Partial Resonant Switching $3\phi$ Boost Converter with High Efficiency Using Lossless Snubber)

  • 전종함;서기영;이현우
    • 전자공학회논문지S
    • /
    • 제34S권9호
    • /
    • pp.118-125
    • /
    • 1997
  • This paper proposed a new partial resonant 3.PHI. AC-DC boost converter of high efficiency using lossless snubber. The proposed converter, DCM (Discontinuous Current Mode) has a merit of simple controlled circuit because the input current control discontinuously. But turned off switching loss and stress of the switching device increase when the switch turned off at the peak of current. Therefore, the paper improves efficiency by adopting the PRS$^{2}$(Partial Resonant Soft Switching) in 3.PHI. AC-DC boost converter and makes the unity power factor. The PRS$^{2}$ is reduced a current/voltage stresses of switching devices. Also, a DCMPRS$^{2}$M(Discontinuous Conduction Mode Partial Resonant Soft Switching Method) appear the current and voltage equation of this circuit. The paepr examine in a 3.PHI. AC-DC boost converter and show the result of that.

  • PDF

불연속전도모드를 갖는 브리지리스 PFC의 제어 (Control of a Bridgeless PFC with the Discontinuous Conduction Mode)

  • 나재두;이용근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.248-253
    • /
    • 2014
  • Generally, power factor correction (PFC) techniques play an important role in the power supply technology. Many new circuit topologies and control strategies for PFC have been proposed. Among them, the brideless PFC (BPFC) reduces the number of switching devices and the losses and improves the power density as well. Moreover, by implementing the improved topology in the discontinous conduction mode (DCM) it ensures almost unity power factor in a simple and effective manner. In the DCM operation gives additional advantages such as zero-current turn-on in the power switches, zero-current turn-off in the output diode and reduces the complexity of the control circuitry. In this paper, a new control strategy for the BPFC is proposed. Also, the performance of the proposed system is demonstrated through experiments.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

부스트 컨버터의 불연속 전류모드에서 주파수 제어를 통한 최대전력전달추종 (Direct Frequency MPPT Control using a Boost Converter of Discontinuous Current Mode)

  • 최병민;전영태;모하나;박종후
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.357-358
    • /
    • 2014
  • 본 논문에서는 태양광 모듈의 최대 전력점을 추종하기 위한 제어 기법으로 부스트 컨버터(boost converter)의 불연속 전류모드(Discontinuous Current Mode)에서 주파수를 제어하는 기법을 구현 하였다. 태양광 모듈에 연결된 부스트 컨버터는 전압루프를 통하여 Perturb and Observation(P&O)기법을 사용하여 최대 전력점을 추종하였다. 부스트 컨버터의 인덕터에 흐르는 전류는 불연속 전류모드로 제어 된다. 불연속 전류모드에서의 제어기 설계는 MATLAB과 PSIM의 전달함수특성을 수학적 모델링을 통하여 비교 검증 하였으며, 모든제어는 MCU(TEXAS INSTRUMENTS사의 DSPF28335)를 통해 디지털로 제어 하였다. 제안된 기법은 단일 PV모듈이 연결된 불연속전류모드 부스트 컨버터를 통해 동작특성을 분석하였다.

  • PDF

DCM에서 PV시스템용 부스트 컨버터의 개선된 제어방식 (The Modified Control Method of Boost Converter for PV System in DCM)

  • 이영진;한동화;변병주;최중묵;바이스갈랑;최규하
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.297-304
    • /
    • 2013
  • This paper presents a improved control technique to overcome disadvantage when the inductor current of boost converter in PV system becomes DCM(Discontinuous Conduction Mode) due to the low insolation. MPPT(Maximum Power Point Tracking) output reference voltage could not be exactly followed by conventional dual-loop PI control method used typically because of the error between the actual current and measured current. Therefore, in this paper, Hybrid controller that changes the control method in DCM and CCM(Continuous Conduction Mode), and single state feedback controller are used to compensate that problem. The proposed control technique was verified by simulation using PSIM 9.0 and experiments.

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

상태평균화법에 의한 직류초퍼구동 DC모터 제어시스템의 해석과 설계에 관한 연구 (A study on the analysis and design of the chopper fed DC Motor control system using state space averaging method)

  • 유권종;김용주;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.352-356
    • /
    • 1990
  • In this paper proposed a new analysis method that can be controlled DC separately excited motor using DC chopper. An analysis method can be broadly divided the state variables method and the state space averaging method. The state variable method is largely used for analysis method in the time area, but it is complicated analysis of the nonlinear circuit and modeling of the system. Therefore a boundary of the current continuous mode and discontinuous mode can be definited by the state space averaging method. Also this paper proposed a new approximation analysis method using state space averaging method in the discontinuous mode.

  • PDF