• Title/Summary/Keyword: Discharges

Search Result 1,132, Processing Time 0.031 seconds

The Design Method of Transverse Grate Inlets on Steep Local Road (급경사 국지도로에서의 횡유입부 설계 방법)

  • Kim, Jea-Kwon;Kim, Jung-Soo;Lee, Joon-Ho;Yoon, Sei-Eui
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.195-198
    • /
    • 2007
  • The type, the length, and the install space of the grate inlets in main street were designed with the consideration of discharge calculated with street surface rainfall. However, the discharge that was not intercepted at transverse grate inlets in steep local roads increases inundation areas around main street Therefore, it is necessary to analyze the flow characteristics and interception capacity at transverse grate inlets in steep local roads. Hydraulic experimental apparatus which can be changed the longitudinal slopes($2{\sim}10%$) of street, the size ($20{\sim}50cm$) and the types(TYPE I, II) of grate inlet was installed for this study. The range of the experimental discharges were from $2{\ell}/sec$ to $24{\ell}/sec$. The interception discharges of transverse grate inlets per unit width changing the longitudinal slope of steep local road were calculated by the hydraulic experimental results. The design method of transverse grate inlets was developed by the interception discharges per unit width. This design method was applied to decide the space and size of transverse grate inlets.

  • PDF

A Study on NOx Removal Efficiency Depending on Electrode Configurations of Silent Discharges (무성방전 플라즈마 전극구조에 대한 질소산화물 제거효율 연구)

  • Hyung-Taek Kim;Young-Sik Chung;Myung-Whan Whang;Elena. A. Filimonova
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.112-117
    • /
    • 2002
  • A comparative investigation of an experimental and a simulation of chemical kinetics for NOx removal from silent(dielectric-barrier) discharges is presented. Several types of dielectric-barrier discharges were implemented depending upon the configuration of electrodes. The simulation was based on an approximate mathematical model for plasma cleaning of waste gas. The influence of non-uniform distributions of species due to the production of primary active particles in the streamer channel was taken into account. A comparison of observed experimental to the calculated removal efficiency of NOx showed acceptable agreement.

Development of A Computer Simulation Program of Emitter Discharges for Trickle Application (점적 급액 방식에서의 양액 공급량 예측 프로그램의 개발)

  • 오길근;류관희;홍순호
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.390-396
    • /
    • 1995
  • This study was conducted to develop a computer simulation program for trickle application of nutrient solution. A computer simulation program using finite element method was developed to evaluate discharges of emitters on trickle application. The uniformity of application for two different lateral line lengths and three application methods was evaluated by the computer simulation program. The results of this study are as follows. 1. A computer simulation program was developed to determine emitter discharges from a trickle application system and pressures at emitter positions by finite element method and to design a uniform trickle application system. 2. The simulation program developed was verified by experiment. The root mean square error between experimental data and simulated data was 1.1% on the average discharge and it was found that the computer simulation program was an effective tool for the design of a trickle application system of nutrient solution. 3. The uniformity of trickle application system was evaluated for three different methods of supplying nutrient solution with different lateral line lengths. The best uniformity was obtained from the method, which supplies nutrient solution from both ends alternatively for the same period of time.

  • PDF

A Methodology of Finding the Direction of Lightning Discharge using Loop-type Magnetic Field Sensors (루프형 자계센서를 이용하여 뇌방전이 발생한 방향을 탐지하는 기법)

  • Lee, Bok-Hee;Cho, Chi-Youn;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.63-68
    • /
    • 2014
  • This paper deals with a methodology that applies the time-varying magnetic fields produced by the cloud discharges to find the direction of thunderstorm movement. We investigated the basic performance of the magnetic field measurement system composed of multi-turn loop-type sensors, the differential amplifier and active integrator. As a result, the response characteristics of the magnetic field sensor system to sinusoidal signals was excellent. The frequency bandwidth ranges from about 1 kHz to 500 kHz, the response sensitivity was 0.16mV/nT. In addition, we proposed the algorithm that determines the direction of lightning discharges using the comparison of the output signals of right-angled loop-type magnetic field sensors. The accuracy of the direction finding of lightning discharges is fairly well within the measurement error of less than $5^{\circ}$. The magnetic field measurement system proposed in this work can be used to track the direction of thunderstorm movement.

Improved Ultrasonic Method for Locating Partial Discharges in Transformers (개선된 초음파방법에 의한 변압기내 부분방전 위치 검출)

  • Kwak, Hee-Ro;Kim, Jae-Chul;Cho, Kook-Hee;Han, Min-Koo;Lim, Ju-Il;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.252-257
    • /
    • 1988
  • This paper discribes an improved technique for locating partial discharge sites within operating transformers by ultrasonic method which utilizes the different travel times of the electrical and ultrasonic signals produced by partial discharges to determine the location of the sources. The technique was to develope the measurement system based on the enhancement of the acoustic emission signals using signal square, circuit to improve the detectable sensitivity and reliability. Also an ultrasonic pulse generator was designed and made to transmit periodically pulses equivalent to pratial discharges and to check the good performance of the system, echo effects and self-diagnosis. Through the laboratory work, it was confirmed that the system and the generator can be used satisfactorily for diagnosing power transformers and for studying echo effects and self-diagnosis of the system.

  • PDF

Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition (여러 환경조건에 대한 고분자애자의 누설전류 특성 변화)

  • Park Jae-Jun;Choi In-Hyuk;Lee Dong-il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

An application of NN on off-line PD diagnosis to stator coil of Traction Motor (견인전동기용 고정자 코일의 off-line 부분방전 진단을 위한 NN의 적용)

  • Jeon, Yong-Sik;Park, Seong-Hee;Jang, Dong-Uk;Park, Hyun-June;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.653-657
    • /
    • 2004
  • In this study, PD(partial discharge) signals which occurrs at stator coil of traction Motor are acquired. these data are used for classifying the PD sources. W(Neural Network) has recently applied to classify the PB pattern. The PD data are used for the learning process to classify PD sources. The PD data come from normal specimen and defective specimens such as internal void discharges, slot discharges and surface discharges. PD distribution parameters are calculated from a set of the data, which is used to realize diagnostic algorithm. NN which applies distribution parameters is useful to classify the PD patterns of defective sources generating in stator coil of traction motor.

  • PDF

Dependence Analysis of Radical and Ion Densities on Plasma Parameters in $Cl_2$/Ar Discharges ($Cl_2$/Ar 방전에서의 플라즈마 변수에 대한 이온과 라디칼 밀도 의존성 분석)

  • An, Choong-Gi;Kwon, Deuk-Chul;Yu, Sin-Jae;Kim, Jeong-Hyeong;Yoon, Nam-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.103-103
    • /
    • 2010
  • Dependence of radical and ion densities on Plasma Parameters is theoretically investigated in $Cl_2$/Ar plasma discharges. Firstly, a set of reliable rate coefficients is obtained by direct calculations with cross section data set and by comparing them with previously reported values. Then, some global discharge simulations are performed for ICP(inductively coupled plasma) discharges and the results are compared with experimental results. Finally, the validated data set is used to analyze the dependence of radical and ion densities, which are usually not easy to be measured, on electron density arid temperature.

  • PDF

The Runoff Characteristics due to Heavy Rainfall in Mountainous River (산지하천의 집중강우에 따른 유출특성에 관한 연구)

  • Kang, Sang-Hyeok;Choi, Jong-In;Park, Jong-Young
    • Spatial Information Research
    • /
    • v.15 no.2
    • /
    • pp.159-167
    • /
    • 2007
  • In this study, we investigated the application of extending the Huff's method to design discharge being used at present up to the event of concentrated rainfall. As our field study site, we selected Odae Cheon basin in Pheongchang, which was affected by concentrated rainfall in July 2006. Actual concentrated rainfall and design rainfall derived from the Huff's method were used to calculate the discharge and storm water levels, which were compared with the directly measured water-level marks of storm discharges. The results showed that the peak storm discharge from the torrential rainfall was twice higher than the design rainfall. The short term discharges from concentrated rainfall closely corresponded to the rainfall discharges of 150 years storm frequency.

  • PDF