• Title/Summary/Keyword: Discharged water

Search Result 763, Processing Time 0.024 seconds

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

A study on the estimation of the downstream arrival time with the upstream flow by utilizing u-IT equipments (u-IT 장비를 활용한 상류 유하량에 따른 하류지점 도달시간 예측에 관한 연구)

  • Kim, Jin-Young;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3594-3602
    • /
    • 2011
  • The purpose of this study is complementing existing flood-reaching timetable by theoretically determined numerical model and suggesting techniques for calculating the exact arrival time of flood. For this, according to the discharge of Namhan River, arrival time measurements, using u-IT technology applied sensor buoys, were performed. Based on the results of measurements, this study proposed complementary relation of average reach time by the discharged water considering tributary inflow, which was not considered established expression. With this study, u-IT based actual technology that is complementing the existing flood forcasting-warning data was developed. Applying this technology to the average reach time calculation by the discharged water, it is expected to reduce flood-oriented damage.

Analytical Study on the Discharge Transients of a Steam Discharging Pipe (증기방출배관의 급격과도현상에 대한 해석적 연구)

  • 조봉현;김환열;강형석;배윤영;이계복
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.202-208
    • /
    • 1998
  • As in the other industrial processes, a nuclear power plant involves a steam relieving process through which condensable steam is discharged and condensed in a subcooled pool. An analysis of steam discharge transients was carried out using the method of characteristics to determine the flow characteristics and dynamic loads of piping that are used for structural design of the piping and its supports. The analysis included not only the steam flow rate but also the flow rates of the air and water which originally exist in the pipe. The analytical model was developed for a uniform pipe with friction through which the flow was discharged into a suppression pool. Including the combinations of system elements such as reservoir, valve and branching pipe lines. The piping flow characteristics and dynamic loads were calculated by varying system pressure, pipe length, and submergence depth. It was found that the dynamic load, water clearing time and water clearing velocity at the water/air interface were dependent not only on the system pressure and temperature but also on the pipe length and submergence depth.

  • PDF

Long Term Monitoring of Storm Surface Runoff from Urban Pavement Road in Korea

  • Lee, C.S.;Seo, G.T.;Lee, J.H.;Yoon, Y.S.;You, J.J.;Sin, C.K.
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.184-191
    • /
    • 2008
  • Long term monitoring was conducted to investigate a surface runoff of pollution from urban highway. The monitoring data was collected for 18 rainfall events and was used to correlate pollution load to various parameters, such as rainfall intensity, antecedent dry days and total discharge flow. Runoff coefficient and seasonal variation were also evaluated. The mean runoff coefficient of the highway was 0.823(range; $0.4687{\sim}0.9884$), and wash-off ratio for $COD_{Mn}$ and SS loads was 72.6% and 64.3%, respectively. For the initial rainfall event, the runoff EMC of $COD_{Mn}$ was high in summer and the EMC of SS was high in autumn season. However the seasonal variation of T-N and T-P was not significant. The discharged $COD_{Mn}$-EMC was $147.6\;mg/L{\sim}9.0\;mg/L$ on the generated $COD_{Mn}$-EMC of $98.8\;mg/L{\sim}8.9\;mg/L$. While the generated EMC of SS was in $285.7\;mg/L{\sim}20.0\;mg/L$ and its discharged EMC was in $190.4\;mg/L{\sim}8.0\;mg/L$. EMC of pollutants was not directly related to the first flush rainfall intensity and the antecedent dry days. But the correlation was relatively high between EMC and cumulative runoff flow volume. The trend of EMC was reduced with the cumulative runoff flow volume.

Assessment of Korean Water Quality Standards for Effluent Discharged from the Dye Industry Based on Acute Aquatic Toxicity Tests Using Microbes and Macroinvertebrates (염색폐수의 수질독성시험을 이용한 한국의 수질배출허용기준 평가연구)

  • Kim, Young-Hee;Lee, Min-Jung;Choi, Kyung-Ho;Eo, Soo-Mi;Lee, Hong-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Acute aquatic toxicity of effluents discharged from five dyeing plants in Gyeong-gi province were evaluated to assess whether the current Korean water quality standards(KWQS) could protect aquatic life. Chemical analyses of all parameters regulated under KWQS, except for E-coli, were also carried out to determine regulation compliance of the samples. All the effluent samples were satisfied with KWQS except for the color in only one sample. In acute Daphnia magna toxicity tests, significant mortality was observed in one of five samples and EC50 was 12.1%(95% confidence interval 9.1-16.2), which was in compliance with KWQS. The result of the Microtox assay indicated that acute microbial toxicity existed in effluents from three out of five plants, two of which were in compliance with KWQS. The agreement between regulation compliance of chemical concentrations of effluent and observed toxicity from various biological toxicity tests was very poor to fair (kappa = 0.194~0.250). The data presented suggest that exposure to dyeing wastewater which were in compliance with Korean water quality standards may not be safe to aquatic biota, and multiple tropical levels should be considered in aquatic toxicity monitoring of dyeing industry.

A Hydrodynamic Analysis for Prevention of Seawater Influx into an Outfall Riser in the Wastewater Treatment Plant (하수처리장 방류관거로의 해수유입 방지를 위한 수리분석 - 인천 학익하수처리장을 중심으로 -)

  • Shin, Kwang-Seob;Jeong, Sang-Man;Lee, Joo-Heon;Oh, Kuk-Ryul
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.759-762
    • /
    • 2008
  • A wastewater treatment plant located in coastal areas should be built considering the discharge of rainwater and treated water into the sea. The current Hagik Wastewater Treatment Plant in Incheon City was designed in the surface discharge method, which refers to discharging treated water directly into the sea. This method may cause hydrodynamic issues in a wastewater treatment plant because seawater enters an outfall riser when the level of discharged water is lower than the tidal level on a shore with high tidal range. In this study, a method for installing a weir in the discharge manhole was proposed in order to prevent seawater from entering the outfall riser of a wastewater treatment plant. Its feasibility was reviewed by calculating the hydrodynamic that had occurred due to the installation of the weir. As a result, seawater did not enter in the discharge manhole. Thus, even if the coast of Incheon City reaches the highest tidal level, treated water will be able to be properly discharged.

  • PDF

Behavior Analysis of Discharged DIC Concentrated Seawater through Towed Pipe Injection from Ship

  • Kwon, Seong-Min;Kim, Kang-Min;Song, Hyeon-Woo;Lee, Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.43 no.2
    • /
    • pp.79-85
    • /
    • 2019
  • Climate change is a very vital issue that can be no longer avoided. Korea has been a top-level country Iin dealing with carbon dioxide emissions since 1960. Many studies have been conducted to suppress or eliminate carbon dioxide emissions, which account for a large portion of greenhouse gases. Carbon Capture and Storage (CCS), the most practical method of them, plays a significant role. However, these methods have the disadvantage of the limits of geographical distribution and high possibility of re-emission into the atmosphere. Recently, ocean storage has been studied using Accelerated Weathering of Limestone (AWL), a technique for storing carbon dioxide in the ocean as an alternative to CCS, an underground storage. AWL is a method of converting carbon dioxide into concentrated water in the form of bicarbonate ion and discharging it to the ocean to dilute and store it. It does not cause re-emission to the atmosphere, and the discharged concentrated water increases the alkalinity of the ocean to prevent marine acidification. The objective of this study was to understand the behavior of DIC (Dissolved Inorganic Carbon) including carbon dioxide during the ocean discharge of bicarbonate ion concentrated water in AWL method. This study area was set near Ulleung-do where sufficient water depth and operational efficiency were secured. CORMIX model was used to calculate the material diffusion by submerged discharge using ship.

Development of a Decision Support System for Turbid Water Management through Joint Dam Operation

  • Kim, Jeong-Kon;Ko, Ick-Hwan;Yoo, Yang-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.31-39
    • /
    • 2007
  • In this study we developed a turbidity management system to support the operation for effective turbid water management. The decision-making system includes various models for prediction of turbid water inflow, effective reservoir operation using the selective withdrawal facility, analysis of turbid water discharge in the downstream. The system is supported by the intensive monitoring devices installed in the upstream rivers, reservoirs, and downstream rivers. SWAT and HSPF models were constructed to predict turbid water flows in the Imha and Andong catchments. CE-QUAL-W2 models were constructed for turbid water behavior prediction, and various analyses were conducted to examine the effects of the selective withdrawal operation for efficient high turbid water discharge, turbid water distribution under differing amount and locations of turbid water discharge. A 1-dimensional dynamic water quality model was built using Ko-Riv1 for simulation of turbidity propagation in the downstream of the reservoirs, and 2-dimensional models were developed to investigate the mixing phenomena of two waters discharged from the Andong and Imha reservoirs with different temperature and turbidity conditions during joint dam operation for reducing the impacts of turbid water.

  • PDF

Characteristics of Organics and Ammonia Nitrogen Discharged by Pollution Source from Human Living (생활계 오염원의 유기물 및 암모니아성 질소 배출특성 평가)

  • Han, Song-Hee;Kim, Yo-Yong;Sung, Yeon-Gook;Park, Ik-Beom;Cho, Deok-Hee;Nam, Woo-Kyung;Kim, Chang-Gyu;Oh, Jo-Kyo
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.377-386
    • /
    • 2015
  • The purpose of this research was to suggest the water quality improvement in streams by evaluating the distribution characteristics of organics and ammonia nitrogen discharged by pollution sources from human living. The public sewage treatment plants'(PSTPs) effluents and the waters from streams in Gyeonggi-do were sampled and analyzed. Nitrogenous oxygen demand (NOD) was measured for the stream waters as well as the PSTPs effluents, and the correlations of NOD and $NH_3$-N, $NH_3$-N and water temperature in the PSTPs effluents were confirmed. In the case of the stream waters, the ratios of NOD to BOD and $NH_3$-N increased in the downstream sites after discharging the PSTPs effluents. As a result of statistical analysis of $NH_3$-N concentrations for the national water quality monitoring streams in Gyeonggi-do, $NH_3$-N showed the non-normal distribution which were biased to the left, but showed the considerable level because of higher coefficient of variation. Therefore, it is required to establish the water quality standard for the $NH_3$-N as a new parameter for judging the quality of the streams. In addition, inducing complete nitrification and introducing a logical standard setting system are needed to improve the water quality of streams by identifying distribution of the nitrogen components from PSTPs effluents.

An assessment of the effect of air scouring and swabbing pig cleaning technique on water distribution pipes (공기주입과 스와빙 피그를 이용한 상수관로 세척 효과 평가)

  • Bae, Cheolho;Lee, Doojin;Choi, Doo-Yong;Jun, Hongjin;Park, Sehyun;Choi, Taeho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.459-468
    • /
    • 2015
  • Deposits discharged through the cleaning mainly were cement mortar, bitumen paintings and rust pieces, and fragments of perforation, stones and gravels. Deposits were more removed through swabbing pig cleaning rather than air scouring cleaning on the whole. However, air scouring cleaning were not influenced by the constraint conditions such as a change in the diameter or the presence of the valve in water mains compare to swabbing pig cleaning. So, it was thought that air scouring cleaning might be more favorable to water distribution network cleaning in the future. After the cleaning, water quality including residual chlorine and turbidity also was improved because of the removal of a significant amount of the deposits. Therefore, if the cleaning is continuously and regularly implemented in water mains, it is expected that it will help to recover the reliability and to preserve the health of water quality.