• 제목/요약/키워드: Discharge velocity

검색결과 604건 처리시간 0.028초

GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구 (A Study for the Fault Location of Insulation Defects considering Waveguide Characteristics in GIS)

  • 이승철;정승용;이재호;구자윤
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.252-255
    • /
    • 2008
  • A study for discharge pattern analysis partial and fault location by use of UHF sensors in GIS. However, in the latter case, the results considered the velocity of EM waves modified by the waveguide characteristics of GIS bus bar were not reported yet. In this paper, UHF wide band sensor to detect partial discharge signals have been designed and manufactured to get the widest band characteristic by an application of Fat-Dipole UHF antenna and the result that the transmission velocity of EM waves is 2/3 of the light have been got through the consideration of waveguide characteristics. Also, to verify applicability on site of the developed method, self-designed external type UHF sensor have been installed on operating GIS in Korea Midland Power co. and detected location of the fault. Through the fault have been found at the location, the reliability of the developed method have been proved.

자동유량측정시설의 유량산정방법 개선 (Improvement to the Methods of Discharge Computation for the Automated Real-time Discharge Measurement System)

  • 송재현;김대영;진환석;노영신;김치영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.472-477
    • /
    • 2010
  • 자동유량측정시설은 연속적인 유량자료를 측정하기 위해 운영되는 실시간-무인화 유량측정 시스템이다. 현재 국내 외에서 유량측정을 위해 설치 및 운영되고 있는 자동유량측정시설은 대부분 초음파유속계를 이용하고 있는는데, 초음파유속계는 유속을 측정하는 방식에 따라 크게 도플러방식 초음파유속계(ADVM, Acoustic Doppler Velocity Meter)와 이동시간차방식 초음파유속계(UVM, Ultrasonic Velocity Meter)로 분류된다. 본 연구에서는 각 방식별로 유량산정방법을 개선하기 위해 설치 운영 중인 자동유량측정시설 중 고령교 지점의 ADVM 방식과 여주, 적성 지점의 UVM 방식을 대상으로 측정성과에 대한 문제점을 분석하고 통계적인 방법을 통해 오측유속을 제거하거나 방식별 또는 지점별 특성을 고려하여 적절한 유량산정방법을 적용하였다. 그 결과 3개 지점에 대한 검증유량과의 평균 상대오차율은 모두 10% 이내로 나타났다.

  • PDF

PIV를 이용한 DBD 플라즈마 유도 유동장 운동량의 예측 (Momentum Measurement of Induced Flow by DBD Plasma Using PIV)

  • 손준하;김남훈;김경연
    • 한국가시화정보학회지
    • /
    • 제17권1호
    • /
    • pp.53-59
    • /
    • 2019
  • Particle image velocimetry is performed in order to analyze flowfield induced by a dielectric barrier discharge plasma actuator. The velocity vector fields are obtained for the two different input voltage conditions; the voltage 3 and 5 kV at the frequency 10 kHz. The obtained flowfields show that the air is accelerated and its speed increase almost linearly over the covered electrode. The amount of momentum induced by the DBD plasma actuator is estimated from the obtained velocity fields, and the estimated values reasonably agree with the previous experiment.

엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구 (A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept)

  • 추태호;옥치율;김진원;맹승진
    • 대한토목학회논문집
    • /
    • 제29권4B호
    • /
    • pp.357-363
    • /
    • 2009
  • 일반적으로 사용되는 관수로의 평균유속을 구하려면 Darcy-Weisbach의 마찰손실수두공식을 사용하면 되나, 그러나 이 식의 마찰손실계수 f는 Reynolds수와 상대조도(${\varepsilon}$/d)의 함수이므로 사용하기에 매우 불편하며 따라서 보다 편리한 식이 요구된다. 이에 본 연구에서 Chiu 유속공식의 신뢰성과 정확성을 증명하기 위하여 관수로에서 비삽입식 유속측정 장치인 레이저 유속계(Laser Doppler Velocimeter: LDV) 및 초음파 유량계(Ultrasonic Flowmeter: U/F), 삽입식 유속측정장치인 피토관 (Pitot Tube)을 이용하여 실측한 유속측정 자료와 Chiu의 공식을 이용한 유속분포가 매우 잘 일치함을 증명하였다. 유량의 증감에 관계없이 실험실 수로에서의 최대유속과 평균유속간의 이론적인 선형관계를 증명함으로써 관수로내 유속의 평형상태, 즉 엔트로피 파라미터 M값에 대응하는 평형상태에 도달하려 하고 이 평형상태를 지속적으로 유지하려고 하는 경향이 있음을 증명하였다. 또한, 한 단면을 대표하는 엔트로피 파라미터 M값이 결정되면 최대유속이 발생하는 지점에서의 유속 측정만으로 단면 전체의 평균유속을 쉽게 구할 수 있고 이로부터 간단히 유량을 산정할 수 있음을 증명하였으며, 이는 추후 관수로 설계 및 운영관리 시 가장 중요한 평균유량을 측정할 수 있는 이론적인 도구로 사용될 수 있음을 의미하는 것이다.

박용디젤기관의 대기오염 저감을 위한 전기 다단 임팩션 시스템의 집진특성 (Collection characteristics of electro-static multi-staged impaction system for air pollutants removal of marine diesel engines)

  • 여석준;권준형
    • 수산해양기술연구
    • /
    • 제51권4호
    • /
    • pp.545-552
    • /
    • 2015
  • The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below $148mmH_2O$ lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage, the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.

2차원 이송-확산 모형을 이용한 취수장 유입 수질 예측 (Water Quality Modeling for Intake Station by 2-dimensional Advection-Dispersion Model)

  • 김재동;김지훈;김영도;송창근;서일원
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.667-679
    • /
    • 2011
  • In this study, the influences of pollutant from Dae-po Stream and So-gam Stream located at the downstream of Nak-dong River on the water quality at Mul-geum water intake station were analyzed using RAMS model. Field measurements of velocity by ADCP, and water quality distribution of BOD and TP by water sampling were carried out to present the input and verification data for numerical simulations. The comparison between RAM2 and ADCP measurement, which aimed for the analysis of 2-D velocity distribution around Mul-geum water intake station showed that two results matched well along the spanwise direction. The prediction of pollutant concentration by RAM4 agreed fairly well with the measured data except for the points nearby right banks in the vicinity of tributary pollutant source. Flushing effect by the increase of mainstream discharge in Nak-dong River was analyzed to provide the damage mitigation in preparation for the accidental water pollution. With increasing mainstream discharge, high velocity and increased water quantity induced increasing dilution effect, thereby decreasing the inflow pollutant concentration rapidly.

유량제어밸브 개방형태가 선형펌프 방식 수중사출 시스템에 미치는 영향에 관한 수치적 연구 (Numerical Investigation of Effect of Opening Pattern of Flow Control Valve on Underwater Discharge System using Linear Pump)

  • 이선주
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.255-265
    • /
    • 2019
  • In the present study, the effect of opening patterns of a flow control valve on underwater discharge systems using a linear pump was investigated numerically. For that, a improved mathematical model was developed. The improvement is to separate a middle tank from a water cylinder because the cross-section area of the inlet of the middle tank is an important parameter. To validate the improved model, calculation results were compared with a previous study. The results showed that $2^{nd}$ order or more polynomial opening patterns had an advantage over ramp opening patterns. Higher an order of polynomial resulted in wider operating limits. An escape velocity and a maximum acceleration of underwater vehicle were affected by time derivative of the cross-section area of the flow control valve. Besides, as a velocity profile of the vehicle got closer to linearity, the escape velocity got faster and the maximum acceleration got smaller. And velocities of the vehicle and piston had similar variation trend.

왕복동식 압축기 흡입 및 토출밸브의 동적 거동 고찰 (Study on the Dynamic Behavior of Suction and Discharge Valves in Reciprocating Compressor)

  • 김성원;박정희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.136-142
    • /
    • 1998
  • Despite the fact that vibration and noise of suction and discharge valves are important factors to be considered in reciprocating compressor designs, such are still have many problems to be developed. Subsequently, this paper addresses a thorough investigation to retrieve basic data for designing suction and discharge valve. In achieving this goal, the natural frequencies in suction and discharge valve were calculated using finite elements method and compared with the results of experimental method which is driven by the speaker and detected by the Laser Velocity Transducer. Also, it was found that natural frequencies are much affected by the Young's Modulus at the clamp. Therefore, improved experimental setup is suggested to consider the effect of clamping conditions. Consequently improved experimental data have good agreements with the FEM data.

  • PDF

로브형 버너에서의 NOx 배출특성 (Characteristics of NOx emission in lobed burner)

  • 조한창;조길원;이용국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.140-147
    • /
    • 2000
  • Using lobed burner, flame visualization and measurements of NOx and CO concentration in the combustor exit were carried out to evaluate the relation between the lobed structure in a burner and pollutant emission characteristics. The flame stability is enhanced by the lobed burner compared to conventional circular one. The correlation on fuel discharge velocity for flame blowout should be included on a variable related to the wall effect of the burner, because the flame blowout is observed at the burner having large perimeter. The burner having lobed structure in fuel discharge side compared to conventional burner reduces by 5% NOx emission due to lower flame intensity through flame elongation. Meanwhile the burner having lobed structure in air discharge side and both fuel and air discharge side increase the NOx emission.

  • PDF