• Title/Summary/Keyword: Discharge time

Search Result 2,616, Processing Time 0.03 seconds

The Effects of Hospital Home Nursing Interventions based on the Nursing Diagnosis (간호진단중심의 퇴원계획과 가정간호적용의 효과 -만성질환자를 중심으로-)

  • Suh Moon-Ja;Kim Keum-Soon;Kim Myung-Ae;Kim In-Ja;Son Hang-Mi
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.1
    • /
    • pp.50-67
    • /
    • 1996
  • Home nursing interventions based on nursing diagnosis were implemented to the patient who are discharged from one hospital often the treatment for chronic neuromuscular system problem, and its effects were studied. The purpose of this study was to find out the effectiveness of hospital bouned home nursing provided by hospital nurses and to categorize home nursing diagnosis and its interventions. Data from experimental group patients were collected at three different time ; at the time of discharge, two weeks after discharge and our weeks after discharge. Data from controll group patients were collected twice ; the first one at the time of discharge, and the other one four weeks after discharge. For this study nursing assessment and intervention booklet developed by the research team. There were no significant decrease of the number of nursing problems and life satis-faction. But daily activity level of patients showed the signs of significant improvement at the time of four weeks after discharge. Results of this study indicates that home nursing intervention based on nursing diagnosis provided the patients with noticeable difference in health maintanance, impairment of physical mobility, potential for infection, impaired home marntenance management, health seeking behavior, chronic pain, disuse syndrome, impaired skin integrity.

  • PDF

Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea (한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I))

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode (제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구)

  • Park, Keun-Seok;Choi, Jun-Woong;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

The Study on the Properties of He Glow discharge in a Dielectric Barrier Discharge (DBD) Model (DBD 전극구조에서의 He 가스 글로우방전 특성연구)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.214-220
    • /
    • 2018
  • Light sources induced by gas discharge using rare gases have been widely used in the thin film deposition, the surface modification and the polymer etching. A dielectric barrier discharge (DBD) has been developed in order to consistently emit light and control the wavelength of the emission light. However, much research on the characteristics of the movement of discharge particles is required to improve the efficiency of the light lamp and the life-time of the light apparatus in detail. In this paper, we developed a He DBD discharge simulation tool and investigated the characteristics of discharge particles which were electrons, two positive ions ($He^+$, $He_2^+$) and 5 excited particles ($He^*(1S)$, $He^*(3S)$, $He^*$, $He^{**}$, $He^{***}$). The discharge currents showed the transition from pulse mode to continuous mode with the increase of power. With the accumulated charges on the barrier walls, the discharge current was rapidly increased and caused oscillation of the discharge voltage. As the gas pressure increased, $He_2^+$ and $He^*(3S)$ became the dominant activated particles. The input power was mostly consumed by electrons and $He_2^+$ ion. And the change curve showed that power consumption by electrons increased more with gas pressure than with source voltage or frequency.

Assessment of Relationship between Sediment-Discharge Based on Rainfall Characteristic using SWAT Model (SWAT 모델을 이용한 강우특성 변화에 의한 퇴적물-유출량 간의 관계 평가)

  • Kim, Jisu;Kim, Minseok;Cho, Youngchan
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.118-129
    • /
    • 2021
  • The sediment transportation caused by soil erosion due to rainfall-discharge in the large watershed scale plays critical role in human society. The relationship between rainfall-discharge-sediment transportation is depending on the start time of rainfall and end of rainfall but, the studies related with rainfall characteristics are insufficient. In this study, The Soil and Water Assession Tool (SWAT) model was used to study the relationship between rainfall-discharge-sediment transportation at the Sook river watershed which is monitored by the Ministry of Environment. To do this, first of all, the sensitivity analysis about model attributes was performed using monitored data. The accuracy analysis of SWAT model was conducted using the model's efficiency index (Nash and Sutcliffe model efficiency; NSE) and the coefficient of determination (R2). After that, it was studied what results could be obtained according to changes in rainfall timing and end points. In the result of discharge simulation, the modified rainfall values (sum of total rainfall starting time and end time) showed more high accuracy values (R2:0.90, NSE: 0.8) than original rainfall values (R2:0.76, NSE: 0.72). In the result of sediment transportation simulation, during calibration had more resonable results(R2:0.87, NSE: 0.86) than compared with original rainfall values (R2:0.44, NSE: 0.41). However, validation results of sediment transportation simulation showed low accuracy values compared with calibration results. This results maybe cause monitoring periods of sediment flow compared with discharge monitoring periods. Nevertheless, since rainfall characteristic plays critical rule in model results, continuous research on rainfall characteristic is needed.

Effect of Rise Time of a Pulse Bias Voltage on Atmospheric Plasma Generation (대기압 플라즈마 발생시 인가전압의 상승시간에 따른 영향)

  • Kim, Jae-Hyeok;Jin, Sang-Il;Kim, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1218-1222
    • /
    • 2008
  • We investigate the effect of rise time of a pulse bias voltage on atmospheric plasma generation. With the faster rise time of the pulse bias, the glow discharge appears to be more uniformly generated along the electrodes. I-V measurement confirms that higher loading power can be obtained using the faster rise time. A new understanding for atmospheric plasma generation at a micro-gap electrode is suggested.

Characteristics of Surface Morphology According to the Pulse Change When Wire-cut Electrical discharge Machining (와이어컷 방전가공시 펄스변화에 따른 표면형상 특성)

  • 이재명
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.537-542
    • /
    • 2000
  • Wire deflection, surface roughness and roundness were observed on changing discharge time for electrical discharge machining(EDM) of STD-11 in various conditions of thickness. The wire deflection was decreased as increasing discharge time and wire tension. The deflection is the smallest at the speed of wire of 10.6m/min and the water specific resistivity of 5k$\Omega$.cm. The deflection is found to be decreased as increasing dwell time. But if the water pressure is high, it is found not to be changed after the vibration of 4sec. The component of copper(Cu) and zinc(Zn), which is the main material of wire electrode, is observed for rough wire-cutting EDM of STD-11. This phenomena is found to be similar in spite of the change of EDM energy level. But it will be improved by changing the material and the shape of wire. The roundness of middle is found to be worse than that of upper and it is increased as the thickness of material is increased.

  • PDF

Measurement of Tree Growth Characteristics and Acoustics Emission Signals by Partial Discharge in XLPE (XLPE의 부분방전에 의한 트리진전 특성과 음향방출신호 측정)

  • Kim, Seung-Gyu;Lee, Sang-Woo;Lee, Kwang-Sik;Kim, Yeong-Hun;Kim, Geum-Yong;Kim, In-Sik;Kim, Lee-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1954-1956
    • /
    • 2000
  • In this paper, when void of XLPE was existed, electrical tree was growth in branch-type, and it was growth in bush-type when void of XLPE was not existed. Moreover, charge magnitude of partial discharge by deterioration time of XLPE sample was about proportion to output voltage of AE signals. When void was existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased with increasing deterioration time. However, when void were not existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased in fast deterioration time, but it were decreasing at after in middle deterioration time. Frequency spectrum response of AE signal was about 100-250[kHz].

  • PDF

High-Speed Characteristics of Plasma Display Panel using Priming Overlapping with Display Drive Method (표시기간 중첩 프라이밍 구동기술에 의한 플라즈마 디스플레이 패널의 고속구동특성)

  • Ryeom, Jeong-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.2004-2009
    • /
    • 2007
  • A new high-speed drive method for the plasma display panel is proposed. In this method, the address period is inserted for the rest period of the sustain pulses and the priming pulse is applied on the entire panel at the same time overlapping with the sustain period. The ramp shaped priming pulse can be made with a simple drive circuit in this technology and the stable sustain discharge can be induced even by a narrow scan pulse in help of the space charge generated from the address discharge. From the experiments, it is ascertained that the priming pulse hardly influences the sustain discharge. Moreover, the voltage margin of the sustain discharge is almost constant though that of the address discharge broadens with narrowing the scan pulse width. And, if the time interval between the scan pulse and the sustain pulse is within $6{\mu}s$, the voltage margin of the address and the sustain discharges are unaffected though the applied position of the scan pulse is changed. High-speed driving with the address pulse of $0.7{\mu}s$ width was achieved and the address voltage margin of 20V and the sustain voltage margin of 10V were obtained.

The development of discharge reactor for water purification and the fundamental study on the change of water characteristics (수질 개선용 방전 리액터의 개발과 기본적 수질 특성 변화 조사)

  • Han, Sang-Bo;Park, Jae-Youn;Kim, Jong-Seog;Jung, Jang-Gun;Koh, Hee-Seog;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2193-2195
    • /
    • 2005
  • The hybrid discharge reactor was designed for the application of wastewater treatment and the removal of hazardous volatile organic substances in water. This discharge type was similar to the barrier discharge, and the surface discharge on the dielectric surface was propagated to the water surface. That caused the heterogeneous chemical reaction strongly at the interface between the working gases and the water surface. Changes of the conductivity, acidity, and the dissolved ozone with respect to the treatment time and water quantities were studied as the fundamental experiment. The concentration of hydrogen ions largely increased with increasing the treatment time and the conductivity increased with respect to the increase of water quantities under the constant other discharge parameters.

  • PDF