• 제목/요약/키워드: Discharge ratio

검색결과 1,056건 처리시간 0.025초

Polyethylene film의 부분방전열화와 역학적 특성 (Deterioration of Polyethylene Films Induced by Partial Discharge and Variations Observed in Mechanical Properties)

  • 황명환
    • 한국안전학회지
    • /
    • 제4권1호
    • /
    • pp.5-14
    • /
    • 1989
  • 低密度 Polyethylene film을 冷延伸된 方向에 對해서 直勇方向으로 延伸하면, 延伸比 1.2~1.8 付近에서 部分放電에 의한 劣化가 顯著히 增加하고, Void發生에 의한 部分放電 開始電壓이 低下한다. 延伸 film에 對해 强制振動法에 의해 求한 彈性率 및 力學的 tan$\delta$는 上記의 延伸比代近에서 名名 極小 및 極大를 나내고 上記의 傳奇的特性과 密接한 關係가 있다. 더욱이 微結晶은 延伸에 의해 작은 結晶으로 分解되는 것을 X線回折로 認定할 수 있고, 또한 非晶領城의 分子鎖는 高延伸에서 再配向하는 것을 赤外吸收에 의해 認定할 수 있다.

  • PDF

전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향 (Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제25권3호
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

액체로켓 동축 분사기의 유량계수에 대한 고찰 (Study on Flow Discharge Characteristics of Liquid Rocket Coaxial Injectors)

  • 서성현;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.49-53
    • /
    • 2009
  • 본 논문은 액체로켓용 이중 와류 동축 분사기의 유량 특성에 대한 실험적 연구 결과를 수록하였다. 분사기의 추진제 유량 공급 특성은 매우 중요한 로켓엔진 연소장치 설계 인자이다. 분사기 유량 특성 파악을 위해 상온시험은 물을, 연소시험은 액체산소와 케로신을 사용하였다. 상온 시험 결과와 달리 연소시험 유량 계수는 혼합비, 리세스 비 변경에 따라 변화하며 그 변화 정도는 분사기 형상과 작동 조건에 따라 다르다. 연소시험 산화제 측 유량 계수 변동 원인은 물성값 변화에 따른 화염 구조 변화에 의한 것으로 판단된다.

  • PDF

배수갑문의 유량계수 결정에 대한 실험적 연구 (ExPerimental Study on the Determination of Discharge Coefficients in Tide Gates)

  • 권순국;나정우
    • 한국농공학회지
    • /
    • 제28권1호
    • /
    • pp.51-59
    • /
    • 1986
  • Through the hydraulic model test, a more convenient and accurate method of deter- mining discharge coefficients in the sluice type of tide gates can be derived by the use of aubmergence ratio as a parameter. The results obtained are summarized as follows; 1. Discharge coefficients under submerged flow conditions can be obtained by the application of sutmergerice ratio (S) to the free flow equation of the broad-erested we r. 2. The critical submergence ratios (Scr) for the flat basin and the broad-crested types of sill have the same value of 0.8. 3. Under free flow conditions, the discharge coefficient (m) are 0.37 and 0. 35 for the flat basin and the broad-crested types of sill respectively. However, when submerged flow condition exists, the discharge coefficients for both types of sill is given by a regression equation of discharge coefficients (IL) on submergence ratios (8) expressed as; m 1.3- 1. 17S. 4. The relationships between S and Froude number (Fr), for the flat basin and the broad-crested types of sill are Fr=2. 79-2.495 and Fr2.5=5. 7-6.16S respectively. From the above relationships, it can be concluded that m can also be expressed in terms of the Froude number which is a very relevant hydraulic parameter of the open channel hydraulics.

  • PDF

원뿔형 벤츄리수로의 수리특성 (Hydraulic Characteristics in the Movable Venturi Flume with Circular Cone)

  • 김대근
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.177-184
    • /
    • 2013
  • This study analyzed the hydraulic characteristics of a venturi flume with a circular cone using a 3-D numerical model which uses RANS(Reynolds-Averaged Navier-Stokes Equation) as the governing equation. The venturi flume with the circular cone efficiently measures the discharge in the low-flow to high-flow range and offers the advantage of accurate discharge measurements in the case of a low flow. With no influence of the tail-water depth, the stage-discharge relationship and the flow behaviors were analyzed to verify the numerical simulation results. Additionally, this study reviewed the effect of the tail-water depth on the flow. The stage-discharge relationship resulting from a numerical simulation in the absence of an effect by the tail-water depth showed a maximum margin of error of 4 % in comparison to the result of a hydraulic experiment. The simulation results reproduced the overall flow behaviors observed in the hydraulic experiment well. The flow starts to become influenced by the tail-water depth when the ratio of the tail-water depth to the total head exceeds approximately 0.7. As the ratio increases, the effect on the flow tends to grow dramatically. As shown in this study, a numerical simulation is effective for identifying the stage-discharge relationship of a venturi flume with various types of venturi bodies, including a venturi flume with a circular cone.

25.8kV GIS 부분방전 측정전용 UHF센서 개발 (UHF Sensor Development for Partial Discharge Exclusively for Measurement in 25.8kV GIS)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1083-1088
    • /
    • 2016
  • 25.8kV GIS part generated by sensors to measure contact an inflow of noise depending on the extent of the measured discharge occurs often not easy. Partial discharge signal measurement sensor suitable for developing a more useful measurements at the scene to this, partial discharge waveform analysis developed a sensor, and to utilize forSensor on the development of the most important is VSWR decided to (voltage standing wave ratio) voltage standing-wave ratio less than 1.5 and decided less than at the full spectrum bands that are measured, this time Return loss, as measured value by absolute criteria 14.0 dB produced the sensor, designed to or more. UHF 1.5~0.5 GHz bandwidth spectrum to be measured in GIS. UHF bands were designed to be able to measure the best signal. Recently, 25.8kV GIS production company has been increasing variety of GIS were made open spacer in partial discharge in accordance with the not very easy to detect the signal. The sensor is designed height of four cm external spacer is attachment GIS in an influx of outside noise measurement, and be so manufactured as to facilitate the least we've done. Also, since partial discharge which occur can measure the frequency of the 170kV GIS external partial-discharge signals that occur at the scene of insulation applied to the spacer. Features, and also derived good results using global positioning. Also measured discharge point about sensors that are stable and the reliability of the development and local substation equipment failure occurring signal analysis through the discharge for the prevention of widely. There should be to believe that used.

침출수 무배출식 모형매립조를 이용한 도시폐기물 분해특성 (Decomposition Characteristics of Municipal Solid Wastes in Lysimeter Without Leachate Discharge)

  • 류돈식;이해승;이찬기
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.49-57
    • /
    • 2000
  • The objective of this study is to find solid waste decomposition in landfill without leachate discharge. This study was observed variation of landfill gas production rate and leachate for stabilization assessment, and using four sets of lysimeter as experimental apparatus. Soild waste decomposition was accelerated in without leachate discharge system by sufficient moisture for methane bacteria. And gas production rate was between 54.2ℓ/kg VS∼335.9ℓ/kg VS in each lysimeter. Generation time of methane gas was showed different in each lysimeter, but it was much faster than literature research. The time of stabilization phase were began as follows : L-1 400 day, L-2 350 day, L-3 170 day and L-4 70 day respectively. Decreasing times of BOD/COD ratio and C/N ratio were necessary more than literature research because organic matter was not discharge such as wash out.

  • PDF

Xe 가스 첨가에 따른 방전 특성 시뮬레이션 분석 (A Simulation Analysis of the Discharge Characteristics with the Xe Gas Contents)

  • 유일;손영주;이영민;옥정우;남춘우;이돈규
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1650-1655
    • /
    • 2012
  • AC-PDPs have recently achieved good performance and their image quality can sufficiently compete with the LCD TV. However, it is necessary more effort to improve the luminance and luminous efficacy in the PDP technology. The gas mixture ratio plays a very important role in discharge characteristics, but the mechanism of gas discharge is complex and complicated. In this paper, we investigate the mechanism of gas discharge with Ne+Xe miture ratio through zero and two dimensional fluid simulation.

CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구 (An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor)

  • 이익수;강병하
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.

합류부 하상고 불일치에 의한 분리구역 특성분석 (An Analysis on the Characteristics of Separation Zone Due to a Bed Discordance at Confluence)

  • 최흥식;모선재
    • 한국수자원학회논문집
    • /
    • 제48권8호
    • /
    • pp.625-634
    • /
    • 2015
  • 합류부에서의 지류의 합류각, 지류와 본류의 유량비에 추가하여, 본류 준설에 의한 하상고 불일치에 따른 다양한 양상의 분리구역의 특성을 CCHE2D 모형을 사용하여 분석하였다. 분리구역은 지류가 합류되어진 직후 단면에서의 유속이 0(영)인 경계로 정의하였다. 합류각 $30^{\circ}$ 이하에서는 분리구역이 형성되지 않았다. 유량비와 합류각 증가에 따른 분리구역의 크기는 일반적으로 증가하는 양상으로 나타났다. 준설 깊이비 증가에 따른 분리구역의 크기는 합류부 수용체의 증가에 기인한 지류에서의 상대적인 운동량의 감소로 인하여 감소되었다. 유량비와 합류각의 변화에 따른 분리구역의 수축지수를 규명하였고, 통수기능의 저하에 따른 배수영향을 확인하였다. 합류각, 유량비, 준설 깊이비에 따른 분리구역의 형상지수의 관계식을 제안하였다.