• Title/Summary/Keyword: Discharge procedure

Search Result 226, Processing Time 0.026 seconds

A Two-dimensional Turbulence Model for the Thermal Discharge into Crossflow Field (가로흐름 수성으로 방출되는 2차원 온배수 난류모형)

  • Choi, Hung-Sik;Jung, Kyung-Tae;So, Jae-Kwi;Lee, Kil-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 1993
  • A two-dimensional turbulence model for the surface discharge of heated water into cross-flow field has been developed. The depth-averaged continuity, momentum and temperature equations, are solved by an efficient finite-difference procedure known as SIMPLE. Turbulent stresses and heat fluxes are determined from a depth-averaged version of the $textsc{k}$-$\varepsilon$ equation. Results of test run clearly demonstrate its effectiveness in handling strong turbulent phenomena in very shallow near-field region.

  • PDF

Selection of Machining Parameters of Electric Discharge Wire Cut Using 2-Step Neuro-estimation (2단계 신경망 추정에 의한 와이어 컷 방전 가공 조건 선정)

  • Lee, Keon-Beom;Ju, Sang-Yoon;Wang, Gi-Nam
    • IE interfaces
    • /
    • v.10 no.3
    • /
    • pp.125-132
    • /
    • 1997
  • We proposed a 2-step neural network approach for estimating machining parameters of electric discharge wire cut. The first step net, which is described as a backward neuro-estimation, is designed for estimating coarse cutting parameters while the second phase net, as a polishing forward neuro-estimation, is utilized for determining fine parameters. Sequential estimation procedure, based on backward and forward net, is performed using the net's approximation capability which is M to 1 and 1 to M mapping property. Experimental results an given to evaluate the accuracy of the proposed 2-step neuro-estimation.

  • PDF

On-line Test Equipment for Cable Joint by RF Sensing (RF 감지 방식 on-line 케이블 접속재 진단)

  • 이왕하;이성희;정희돈;김덕규;이동영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.661-667
    • /
    • 2003
  • It has little possibility that a cable causes any problem in electric power facilities. But when a trouble occurs in cable or cable joint, the damage is very severe. The main causes of the cable defections are bad cable making procedure, poor cable operation and deterioration according to the years. There are some cases to have potential problems due to many cable connection points, because of short length of cable, especially in 154㎸ system. In this study, novel method to measure partial discharge in cable joints is proposed and the effectiveness and the reliability of the proposed method is shown through experiment results of field.

A Study on the Design of Experiment Planning for Quality Improvement in Flow Shop Manufacturing System (흐름생산시스템에서 품질향상을 위한 실험 계획 설계 -이산화망간-리튬 전지의 품질 향상을 중심으로)

  • 박해천;홍남표
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.63
    • /
    • pp.101-110
    • /
    • 2001
  • This study is concern with the design of experiment planning for quality improvement in flow shop manufacturing system. In this study, the procedure of two stage experiment planning are proposed and applied to the manufacturing process of Li/$MnO_2$ batteries. The result of in this paper is that, compared with the current process conditions, 52% of the insulation inspection process, 81.6% of the first premier discharge process, 98.5% of the second premier discharge process, 84.7% of O.C.V./C.C.V. process, and 86.2% of voltage inspection process are decreased. After a given period of time, the life of the batteries extends to 75 hours, which means the 15% improvement in capacity. In case that the proposed methods are applied to the process Improvements of the flow shop manufacturing system, the much effected in experimental cost- saving and quality improvement.

  • PDF

The Study of Comparison Satisfaction and Re-use Intention between Central and Ward Reception Desk Users (입.퇴원 수속창구 중앙화와 분산화에 따른 이용자의 만족도와 재이용 의사)

  • Ham, Tae-Hoon;Lee, Kyung-Woo;Sohn, Tae-Yong;Yu, Seung-Hum
    • Korea Journal of Hospital Management
    • /
    • v.14 no.4
    • /
    • pp.149-162
    • /
    • 2009
  • The purpose of this study is to design strategic hospital service based on each hospital's features. For this study, an assessment was conducted by 398 in-patents of one university hospital located in Seoul. The self-questionnaires, which were investigated from Oct. 15th to 29th in 2008, compared central reception desk with ward reception desk in satisfaction and re-use rate of patients. The major results of this study are as follow. First, according to each reception desk user, they have different satisfaction of it. As for the staff kindness, admission procedure, discharge procedure and manner of staff, those made patients be gratified as well. Second, when it comes to the intention of re-use, there were no significant features between them. Only convenience in admission and discharge procedure, however, was an attractive factor for the recommendation. Third, this study found out the reasons for higher re-use rate of central reception desk users. Regarding service, they were contented with the time for test and treatment. As for the hospital service, they would like to re-use this hospital because of convenient steps of paying interim fee and getting certificates. Forth, this study found out the reasons for higher re-use rate of ward reception desk users. As a point of hospital service view, they responded that respected privacy, hospital facility and general service were good for staying. As for the manner of staff, they mentioned nurses and staff in charge and whole staff members were kind. When it comes to the procedures of patient management, steps of discharge and paying interim fee were convenience. In conclusion, the results of this study suggest that providing a ward reception desk service can boost the satisfaction and re-use rate of in-patients. Furthermore, this strategic management method would be good for not only cutting the moving line but also efficient in-patient care system. These results can be used for the strategic hospital marketing field, as well. Even though this study has a limitation of the targeted populations which were only in a ward reception desk running hospital, it can say that having competitiveness in satisfaction of hospital service is good for promoting and differencing each hospital. Consequently, whole general management system would be adjusted first for differencing each hospital; however, this sort of additional factor should be concerned as well. I expect that this study would give meaningful data for designing strategic and differencing marketing method to lots of hospitals.

  • PDF

A SVR Based-Pseudo Modified Einstein Procedure Incorporating H-ADCP Model for Real-Time Total Sediment Discharge Monitoring (실시간 총유사량 모니터링을 위한 H-ADCP 연계 수정 아인슈타인 방법의 의사 SVR 모형)

  • Noh, Hyoseob;Son, Geunsoo;Kim, Dongsu;Park, Yong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.321-335
    • /
    • 2023
  • Monitoring sediment loads in natural rivers is the key process in river engineering, but it is costly and dangerous. In practice, suspended loads are directly measured, and total loads, which is a summation of suspended loads and bed loads, are estimated. This study proposes a real-time sediment discharge monitoring system using the horizontal acoustic Doppler current profiler (H-ADCP) and support vector regression (SVR). The proposed system is comprised of the SVR model for suspended sediment concentration (SVR-SSC) and for total loads (SVR-QTL), respectively. SVR-SSC estimates SSC and SVR-QTL mimics the modified Einstein procedure. The grid search with K-fold cross validation (Grid-CV) and the recursive feature elimination (RFE) were employed to determine SVR's hyperparameters and input variables. The two SVR models showed reasonable cross-validation scores (R2) with 0.885 (SVR-SSC) and 0.860 (SVR-QTL). During the time-series sediment load monitoring period, we successfully detected various sediment transport phenomena in natural streams, such as hysteresis loops and sensitive sediment fluctuations. The newly proposed sediment monitoring system depends only on the gauged features by H-ADCP without additional assumptions in hydraulic variables (e.g., friction slope and suspended sediment size distribution). This method can be applied to any ADCP-installed discharge monitoring station economically and is expected to enhance temporal resolution in sediment monitoring.

Development of 4 Types of Fuel Cell's Blower (연료전지 블로어 4기종 국산화 개발)

  • Tak, Bong-Yeol;Kim, Chan-Gyu;Lee, So-A;Jang, Chun-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.91-91
    • /
    • 2011
  • This paper describes development procedure of the four types of fuel cell's blowers: pressurized fuel blower, selective oxidation air blower, cathode air blower, and burner air blower. Diaphragm blowers having two heads are selected to maintain force balance when the rotating arms are moving by the driving motor. Dimensions of a diaphragm cavity is designed according to the optimal design procedure using numerical simulation and experimental measurement. Experimental apparatus is designed by considering the bower characteristics having low flow rate and high pressure. Test blower is operated by a diaphragm, which has suction and discharge port on the top of the blower. For analyzing the internal flow of the blower, three-dimensional Navier-Stokes analysis is introduced in the present study. Throughout the optimal design of the blowers, blower performance is enhanced by reducing the unbalance motion of the rotating arm and loss region in the diaphragm cavity.

  • PDF

Development of Pipe configuration of Air Conditioner Compressor for Vibration Isolation (진동절연을 위한 에어컨 압축기의 파이프 배열기술 개발)

  • 장한기;구치욱;윤덕원;최영훈
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.795-805
    • /
    • 1999
  • Rubber mounts so called grommets and pipes are two major paths of vibration transmission from a compressor, an important vibration source in an air conditioner, to the whole unit. A procedure of configuring the suction and discharge pipes of the compressor was developed in this paper so as to reduce the vibration transmission through the pipes as well as the grommets. Through investigating the effects of shapes and connecting disrections of pipe elements on vibration transmission, a guideline to configure the pipe layout, which enables to reduce vibration transmission, was proposed. The initial pipe layout by the guideline was optimized with the objective function, minimization of boty vibration transmission and the cost, and with the constraints to yield the final dimensions of the pipes. The procedure not only minimizes the transmitted force to the circumferential devices but enables to eliminate rubber blocks or dampers, which are generally used to avoid resonances of the pipe system.

  • PDF

Flow capacity test of spring load safety relief valves used in LNG (LNG 선박용 spring load 안전방출밸브의 유량 성능시험)

  • Park, Kyung-Am;Lee, Saeng-Hee;Kim, Keng-Kuen;Goh, Jang-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.95-98
    • /
    • 2006
  • Many LNG ships will be constructed in Korea and the demand of safety valves is increasing. The most important performance of the developed safety relief valves for LNG ship is flow capacity. Flow capacity tests for 8 sizes of developed safety valves were conducted in the high pressure gas flow standard system in KRISS. The initial spring force adjustment was important for setting pressure of the safety valve. The procedure of data reduction and evaluation of the safety valve performance are suggested. This procedure was approved by French Bureau Veritas and Lloyd's Register.

  • PDF

A Study on Dynamic Characteristics of Reed Valve in Hermetic Compressor (압축기 밸브의 동적 특성에 대한 연구)

  • 조성욱;박성근;김형석;임종윤
    • Journal of KSNVE
    • /
    • v.3 no.2
    • /
    • pp.163-167
    • /
    • 1993
  • Suction and discharge valves of special type refrigerant compressor are designed by finite element method for effective valve design development procedure. It is well known that valve dynamic characteristics, for example, the natural frequencies and vibration modes, are necessary for the computer simulation of compressor valve dynamics, the analysis of flow patterns, noise, impact stresses and their propagation phenomena. This paper has analysed the natural frequencies and vibration modes for the first three orders under the given special boundary conditions and the experiments are conducted by laser holography. And also stress distribution is analysed and experiment by strain gage is followed.

  • PDF