• Title/Summary/Keyword: Discharge procedure

Search Result 226, Processing Time 0.03 seconds

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

Performance effectiveness of pediatric index of mortality 2 (PIM2) and pediatricrisk of mortality III (PRISM III) in pediatric patients with intensive care in single institution: Retrospective study (단일 병원에서 소아 중환자의 예후인자 예측을 위한 PIM2 (pediatric index of mortality 2)와 PRIMS III (pediatric risk of mortality)의 유효성 평가 - 후향적 조사 -)

  • Hwang, Hui Seung;Lee, Na Young;Han, Seung Beom;Kwak, Ga Young;Lee, Soo Young;Chung, Seung Yun;Kang, Jin Han;Jeong, Dae Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1158-1164
    • /
    • 2008
  • Purpose : To investigate the discriminative ability of pediatric index of mortality 2 (PIM2) and pediatric risk of mortality III (PRISM III) in predicting mortality in children admitted into the intensive care unit (ICU). Methods : We retrospectively analyzed variables of PIM2 and PRISM III based on medical records with children cared for in a single hospital ICU from January 2003 to December 2007. Exclusions were children who died within 2 h of admission into ICU or hopeless discharge. We used Students t test and ANOVA for general characteristics and for correlation between survivors and non-survivors for variables of PIM2 and PRISM III. In addition, we performed multiple logistic regression analysis for Hosmer-Lemeshow goodness-of-fit, receiver operating characteristic curve (ROC) for discrimination, and calculated standardized mortality ratio (SMR) for estimation of prediction. Results : We collected 193 medical records but analyzed 190 events because three children died within 2 h of ICU admission. The variables of PIM2 correlated with survival, except for the presence of post-procedure and low risk. In PRISM III, there was a significant correlation for cardiovascular/neurologic signs, arterial blood gas analysis but not for biochemical and hematologic data. Discriminatory performance by ROC showed an area under the curve 0.858 (95% confidence interval; 0.779-0.938) for PIM2, 0.798 (95% CI; 0.686-0.891) for PRISM III, respectively. Further, SMR was calculated approximately as 1 for the 2 systems, and multiple logistic regression analysis showed ${\chi}^2(13)=14.986$, P=0.308 for PIM2, ${\chi}^2(13)=12.899$, P=0.456 for PRISM III in Hosmer-Lemeshow goodness-of-fit. However, PIM2 was significant for PRISM III in the likelihood ratio test (${\chi}^2(4)=55.3$, P<0.01). Conclusion : We identified two acceptable scoring systems (PRISM III, PIM2) for the prediction of mortality in children admitted into the ICU. PIM2 was more accurate and had a better fit than PRISM III on the model tested.

Comparative Analysis of Laparoscopy-assisted Gastrectomy versus Open Gastrectomy (복강경 보조 위절제술과 개복 위절제술의 비교 분석)

  • Lim, Jung Taek;Kim, Byung Sik;Jeong, Oh;Kim, Ji Hoon;Yook, Jeong Hwan;Oh, Sung Tae;Park, Kun Choon
    • Journal of Gastric Cancer
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Purpose: There has been increased the number of early gastric cancer and laparoscopy-assisted gastrectomy (LAG), due to early detection through mass screening program. We started the LAG in April 2004 and performed 119 cases of gastric cancer in 2005, so we report a surgical outcome compared with that of open gastrectomy (OG). Materials and Methods: 119 patients underwent LAG in 2005, and for open group, 126 patiens of early gastric cancer were selected sequentially from January 2005 to March 2005. We compared clinicopathologic characteristics, postoperative courses and complications between two groups. Results: There was no significant difference between age, a length of hospital stay, distal resection margin and a number of retrived lymph nodes. The operation time was longer in LAG group (239.2 vs 123.3 mins, P<0.001) and a diet progression was faster in LAG group (first flatus: 3.05 vs 3.70 days, SOW: 2.86 vs 3.22 days, liquid diet: 3.87 vs 4.19 days, soft diet: 4.84 vs 5.26 days, P<0.001). But there was no difference statistically in postoperative discharge date (7.73 vs 8.25 days, P=0.229). The additional requirement of analgesic injection was less frequent in LAG group (2.97 vs 4.92 times, P<0.001). The harvested lymph nodes were similar in both groups (23.9 vs 23.1, P=0.563). A complication rate was lower in LAG group (4.9% vs 9.5%), but there was no statistical significance (P=0.179). There was no mortality in both groups and no conversion to open gastrectomy in the LAG group. Conclusion: LAG can be performed safely and accepted in view of curative procedure in treatment of early gastric cancer. But we need the follow up of long-term period to evaluate the survival rate and recurrence, and a prospective randomized controlled study should be done to establish that LAG will be a standard operation for early gastric cancer.

  • PDF

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF