• Title/Summary/Keyword: Discharge pressure measurement

Search Result 103, Processing Time 0.029 seconds

Study on the Synthesis of HoN Nanoparticles and Magnetocaloric Effect as Magnetic Refrigerant for Hydrogen Re-Liquefaction (수소재액화를 위한 자기냉매용 HoN 나노분말 합성 및 자기열량효과 연구)

  • Kim, Dongsoo;Ahn, Jongbin;Jang, Sehoon;Chung, Kookchae;Kim, Jongwoo;Choi, Chuljin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.6
    • /
    • pp.594-601
    • /
    • 2014
  • Rare-earth (RE) nitrides can be used as magnetocaloric materials in low temperature. They exhibit ferromagnetism and have Curie temperature in the region from 6 to 70 K. In this study, Holmium nitride (HoN) nano particles were prepared through plasma arc discharge technique and their magnetocaloric properties were studied. Nitrogen gas ($N_2$) was employed as an active element for arc discharge between two electrodes maintained at a constant current. Also, it played an important role not only as a reducing agent but also as an inevitable source of excited nitrogen molecules and nitrogen ions for the formation of HoN phase. Partial pressure of $N_2$ was systematically varied from 0 to 28,000 Pa in order to obtain single phase of HoN with minimal impurities. Magnetic entropy change (${\Delta}S_m$) was calculated with data set measured by PPMS (Physical Property Measurement System). The as-synthesized HoN particles have shown a magnetic entropy change ${\Delta}S_m$) of 27.5 J/kgK in applied field of 50,000 Oe at 14.2 K thereby demonstrating its ability to be applied as an effective magnetic refrigerant towards the re-liquefaction of hydrogen.

The three-dimensional temporal behavior measurement of light emitted from plasma display panel by the Scanned Point-Detecting System (Scanned Point-Detecting System을 이용한 플라즈마 디스플레이 패널에서 방출되는 광의 3차원 시간 분해 측정)

  • 최훈영;이석현;이승걸;김준엽
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.559-563
    • /
    • 2002
  • We measure the 3-dimensional temporal behavior of the light emitted from the discharge cell of a plasma display panel (PDP) by using a scanned point detecting system. The light signal detected by a PM tube is sent to the oscilloscope, and the oscilloscope is connected to a PC with GPIB. From the resultant temporal behaviors, we could analyze the discharge characteristics of the panel with a Ne-Xe (4%) mixing gas at a 400 torr pressure. The top view of the panel shows that discharge moves from the inner edge of the cathode electrode to the outer cathode electrode, forming an arc shape. The side view of the panel shows that the light is detected up to 150 $\mu\textrm{m}$ up the barrier rib. After a trigger pulse is applied, peak intensity is detected at 730 ns and peak intensity position is located at the center of the ITO electrodes.

Water Repellent Finish of Polyester Fabric Using Carbontetrafluoride Plasma Treatment (4불화탄소 플라즈마처리에 의한 폴리에스테르 직물의 발수가공)

  • 모상영;이용운;김태년;천태일
    • Textile Coloration and Finishing
    • /
    • v.6 no.3
    • /
    • pp.27-36
    • /
    • 1994
  • In order to produce a water repellent surface on polyester fabric, samples were treated in the atmosphere of $CF_4$ glow discharge plasma. The samples used in the study were ployester fabric and poyester film. The purpose of film treatment is for the comparison of hydrophobicity with fabric sample at same treatment condition. Radio frequency(13.56MHz) generator was used as electric source and its in put power is 100 Watt. Water repellency was evaluated by contact angle measurement. Result obtained are as follows. 1) Fiber interstice of original fabric was ana lysed as 0.43$\mu$m, and this value was sufficiently ideal for making water repellent fabric. 2) The most favorable setting position of substrate was the center area between two electrodes. 3) Fabric contact angle was higher than film contact angle at same treatment condition, and its difference was more than 50${\circ}$. And it was incapalbe of fabric contact angle measurement when the film contact angle was less than 90${\circ}$. because the fabric is susceptible to absorption of water by the capillary effect. 4) Fabric contact angle can not revealed the precise defferences of surface hydrophobicity, however, the film contact angle showed the real hydrophobic nature. 5) It was not sufficient method to evaluate the hydrophobicity of fabric surface by merely measure of the water contact angle. 6) It showed high water repellent nature at 0.06 torr of $CF_4$ plasma gas pressure and duration of 45 seconds treatment, and it can not be anticipated more improved nature if the pressure and duration of treatment time were increased.

  • PDF

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene (화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.52-59
    • /
    • 2013
  • It was described the measured friction loss depending on pressure used and changes in water flow rates for a fire hose used at a fire scene on this study. As a result of actual measurement based on the result obtained by analyzing the use situation of a fire hose such as the kind, quantity, pressure used, etc. of a fire hose, the friction loss in a fire hose under the condition of using by a fire officer at a fire scene was measured as up to 56.8 %. This is much different from the equivalent length of a fire hose used to calculate the pump head in an indoor and outdoor fire-fighting facility. There is no related restrictive regulation on friction loss, there are even no data on friction loss measured by fire hose makers, and spreading a fire hose without considering friction loss at a fire scene can result in an increased length of hose used and a high-pressure water discharge from a fire engine, so this study aims to establish a standard for an equivalent length to friction loss in a fire hose and to propose a spreading method considering friction loss in a fire hose at a fire scene.

A Fuel Spiking Test for the Surge Margin Measurement in Gas Turbine Engines

  • Lee, Jinkun;Kim, Chuntaek;Sooseok Yang;Lee, Daesung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.380-384
    • /
    • 2004
  • A fuel spiking test was performed to measure the surge margin of the compressor in a gas turbine engine. During the test, fuel spiking signal was superimposed on the engine controller demand and the mixed signals were used to control a fuel line servo-valve. For the superimposition, a subsystem composed of a fuel controller and a function generator was used. During the fuel spiking test, the original scheduled fuel signals and the modified signals were compared to guarantee the consistency excluding the spiking signals. The spiking signals were carefully selected to maintain the engine speed constant. The fuel spiking effects were checked by three dynamic pressure sensors. Sensors were placed before the servo-valve, after the servo-valve, and after the compressor location, respectively. The modulations of the spiking signal duration and fuel flow rate were examined to make the- operating point approach the surge region. The real engine test was performed at the Altitude Engine Test Facility (AETF) in Korea Aerospace Research Institute (KARI). In the real engine test, fuel spiking signals with 25~50 ㎳ of spiking signal time and 17~46 % of base fuel flow rate condition were used. The dithering signal was 5~6 ㎃ at 490 Hz. The test results showed good agreement between the fuel spiking signals and the fuel line pressure signals. Also, the compressor discharge pressure signals showed fuel spiking effects and the changes of the operating point on the compressor characteristic map could be traced.

  • PDF

Measurement of Energy bands of the MgO Layer in AC-PDPs

  • Jeoung, S.J.;Lee, H.J.;Son, C.G.;Kim, J.H.;Park, E.Y.;Hong, Y.J.;You, N.L.;Lee, S.B.;Han, Y.G.;Jeoung, S.H.;Song, K.B.;Moon, M.W.;Oh, P.Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.906-909
    • /
    • 2006
  • The secondary electron emission coefficient $({\gamma})$ of the cathode is an important factor for improving the discharge characteristics of AC-PDPs because of its close relationship to discharge voltage. In AC-PDPs, MgO is most widely used as a surface protective layer. In this experimental, we have investigated the electronic structure of the energy band structure of the MgO layer responsible for the high ${\gamma}$. The MgO layers have been deposited by electron beam evaporation method, where the $O_2$ partial pressures have been varied as 0, $5.2{\times}10^{-5}$ torr, $1.0{\times}10^{-4}$ torr, and $4.1{\times}10^{-4}$ torr, in this experiment. It is noted that work function that is energy gap between surface and first defect level of MgO layer has the lowest value for the highest O2 partial pressure of $4.1^{\ast}10^{-4}$ Torr.

  • PDF

Relationship of Mean Arterial Pressure with the Adverse Outcomes in Adult Blunt Trauma Patients: Cross-sectional Study (성인둔상환자에서 평균동맥압과 위해사건발생의 관련성:단면 조사 연구)

  • Cha, Seung Yong;Kim, Yong Hwan;Hong, Chong Kun;Lee, Jun Ho;Cho, Kwang Won;Hwang, Seong Youn;Lee, Kyoung Yul;Lee, Younghwan;Choi, Seong Hee
    • Journal of Trauma and Injury
    • /
    • v.26 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Purpose: Non-invasive blood pressure measurement is widely used as a pre-hospital triage tool for blunt trauma patients. However, scant data exits for using the mean arterial pressure (MAP), compared to the systolic blood pressure, as a guiding index. The aim of this study was to determine the association between adverse outcomes and mean arterial pressure (MAP) and to exhibit the therapeutic range of the MAP in adult blunt trauma patients. Methods: The electronic medical records for all trauma patients in a single hospital from January 2010 to September 2012 were retrospectively reviewed. Patients below 17 years of age, patients with penetrating injuries, and patients with serious head trauma (injuries containing any skull fractures or any intracranial hemorrhages) were excluded. Adverse outcomes were defined as one of the following: death in the Emergency Department (ED), admission via operating theater, admission to the intensive care unit, transfer to another hospital for emergency surgery, or discharge as hopeless. Results: There were 14,537 patients who met entry criteria. Adverse outcomes occurred for MAPs in range from 90 to 120 mmHg. Adverse outcomes were found, after adjusting for confounding variables, to occur increasingly as the MAP declined below 90 mmHg or rose above 120 mmHg. Conclusion: Not only lower but also higher mean arterial pressure is associated with increased adverse outcomes in adult blunt trauma patients. Thus, patients with a MAP above 120 mmHg should be considered as a special group requiring higher medical attention, just as those with a MAP below 90 mmHg are.

Measurement of excited Xe($1s_4$) and Xe($1S_5$) atoms by laser absorption spectroscopy in coplanar AC-PDP

  • Oh, P.Y.;Lee, J.H.;Moon, H.S.;Hong, J.W.;Jeon, W.;Cho, G.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.515-517
    • /
    • 2004
  • The laser absorption spectroscopy has been used for measuresurement of the xenon atoms in the resonant $1S_4$ and metastable $1S_5$ states in coplanar AC PDP. For the purpose of improving VUV luminous efficiency and optimization of PDP cells, it is important to study behavior of excited Xe atoms in a micro-discharge cell of a coplanar AC-PDP. We measured the xenon excited density of $1S_5$ and $1S_4$ state under mixture gas of Ne-Xe(10%) with gas pressure of 350 Torr and sustaining gap distance of 150 um.

  • PDF

A Study on Emission Characteristics of Ar Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma (13.56MHz ICP에서 단일 탐침법에 의한 Ar 가스의 발광특성 연구)

  • Jo, Ju-Ung;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.611-615
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, Electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an argon discharge for pressure from 10 [mTorr] and input RF power 100 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF