• Title/Summary/Keyword: Discharge pressure measurement

Search Result 103, Processing Time 0.019 seconds

Cardiovascular Neurons Mediating Somatosympathetic Reflex in Rostral Ventrolateral Medulla

  • Goo, Yong-Sook;Kim, Sang-Jeong;Kim, Jun;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.185-197
    • /
    • 1993
  • The rostral ventrolateral medulla (RVLM) includes vasopressor neurons, which transmit activation signals to the intermediolateral nucleus (IML) of the spinal cord, where the preganglionic sympathetic nucleus is located, to raise arterial blood pressure (BP). However, controversy exists as to the possible depressor area in the RVLM and the pathway involved. The present study persued evidence far the location of depressor neurons and the pathway by simultaneously observing changes in BP and the firing rate (FR) of cardiovascular neurons (CVNs) in the RVLM during the somatosympathetic reflex (SSR) elicited by peripheral nerve stimulation, since CVNs are known to contribute to the generation of the sympathetic nerve discharge. In 42 cats, anaesthetized with $\alpha-chloralose$, single unit recording was performed, using carbon filament electrodes inserted into the RVLM, enabling estimation of the post R wave unit histogram (PR-UNlT) and the spike triggered average of sympathetic nerve discharge (STA-SND), allowing identification of CVNs. Antidromic stimulation of spinal $T_2$ segment was followed to determine whether the identified CVN projects axonal endings to the spinal cord (reticulospinal neuron). The sciatic nerve was electrically stimulated at $A\delta-intensity$ (1 mA, 0.1 ms), 1 Hz and C-intensity (10 mA, 0.5 ms), 20 Hz to elicit the depressor, and pressor responses of the SSR, respectively. Simultaneous measurement of CVN firing rate was made. Experimental results are summarized as follows. 1) 20 out of 98 CVNs had axonal projections to the spinal cord and 17 out of 98 CVNs showed FR changes during SSR. 2) Response patterns of FR and BP during SSR were classified into 8 types. 3) These 8 different response patterns could be further classified into those from pressor and depressor neurons. These results demonstrate that some CVNs were identifiable as reticulospinal neurons responding to anti-dromic stimulation and that CVNs operating as depressor neurons as well as pressor neurons exist in the RVLM, both of which are involved with SSR mediation. Therefore, evidence was found that an independent depressor pathway might be involved in the mediation of SSR.

  • PDF

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir with ELCOM-CAEDYM (ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링)

  • Chung, Se-Woong;Lee, Heung-Soo;Ryoo, Jae-Il;Ryu, In-Gu;Oh, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1187-1198
    • /
    • 2008
  • Many reservoirs in Korea and their downstream environments are under increased pressure for water utilization and ecosystem management from longer discharge of turbid flood runoff compared to a natural river system. Turbidity($C_T$) is an indirect measurement of water 'cloudiness' and has been widely used as an important indicator of water quality and environmental "health". However, $C_T$ modeling studies have been rare due to lack of experimental data that are necessary for model validation. The objective of this study is to validate a coupled three-dimensional(3D) hydrodynamic and particle dynamics model (ELCOM-CAEDYM) for the simulation of turbid density flows in stratified Daecheong Reservoir using extensive field data. Three different groups of suspended solids (SS) classified by the particle size were used as model state variables, and their site-specific SS-$C_T$ relationships were used for the conversion between field measurements ($C_T$) and state variables (SS). The simulation results were validated by comparing vertical profiles of temperature and turbidity measured at monitoring stations of Haenam(R3) and Dam(R4) in 2004. The model showed good performance in reproducing the reservoir thermal structure and propagation of stream density flow, and the magnitude and distribution of turbidity in the reservoir were consistent with the field data. The 3D model and turbidity modeling framework suggested in this study can be used as a supportive tool for the best management of turbidity flow in other reservoirs that have similar turbidity problems.