• Title/Summary/Keyword: Discharge of cold

Search Result 160, Processing Time 0.022 seconds

Diffusion Modelling of Cold Discharge on Coastal waters (연안역의 냉배수 확산모델링)

  • Kim, Jong-Kyu;Kim, Jong-Hwa
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.13 no.2
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF

A Study on the Manufacturing Cold Forging Dies by Cold Hobbing (콜드호빙에 의한 냉간단조용 금형제작에 관한 연구)

  • Yoo, Heonil;Kim, Sei-Hwan;Seo, Hee-Kang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.594-603
    • /
    • 1996
  • It has been known that the life time of cold forging dies is shorten by the cracks and wear produced during the operation. Thus it is required to mak the same new one too often, At this time of making new ont the cutting work and electical discharge machining were mormally used. But the precision of product is declined in every times of making the mew dies due to the diffefence in dimensional accuracy arised from the electical discharge machining. Especially it can't meet the delivery date because the production was delayed for making another die. Furthemore it has the problem of increasing the production cost. Therfore inthis study we tried to solve these problems using the hobbing method instead of electical discharge machining.

On the Photoelectric Effects of the Various Kinds of Light Source influencing to the Starting Characteristics of the Cold Cathode Type Discharge Tube (냉음극방전관의 기동특성에 미치는 각종광원에 의한 광전효과)

  • Chee, Chol Kon;Won, Chong Soo
    • 전기의세계
    • /
    • v.13 no.4
    • /
    • pp.10-15
    • /
    • 1964
  • It is well known that the starting characteristics of the cold cathode type discharge tube have photoelectric effects by the incident light from outside. After making the cold cathode type discharge tubes to be avaiable for popularizing, the present paper was devoted primaliry to a study of relations between the starting characterstics and photoelectric effects of discharge tube under the oight circumstances of day light, incandescent lamp, flouresent lamp, and mercury lamp we used frequently. The result of this investigation show that the photoelectric effects by flourescent lamp emitting short wave length having close ralation to the photoelectric effects is greater than incandescent lamp or day light, and also mercury lamp emitting shorter wave length than flourescent lamp indicates the greatest photoelectric effects.

  • PDF

Discharge Characteristics of the Cold Cathode and External Electrode Fluorescent Lamps (냉음극 및 외부전극 형광램프의 방전 특성)

  • Cho Guangsup;Lee Dae H.;Lee Joo Y.;Song Hyuck S.;Gill Doh H.;Koo Je H.;Choi Eun H.;Kim Sang B.;Kim Bong S.;Kang June G.;Cho Mee R.;Hwang Myung G.;Kim Young Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The characteristics of current and voltage in a basic discharge experiment are investigated for a cold cathode fluorescent lamp with ballast capacitors attached at both ends of lamp and for a capacitive coupled external electrode fluorescent lamp. In the current-voltage characteristics for a cold cathode fluorescent lamp except ballast capacitors, it is shown that the typical glow discharge with the cathode fall follows after the dark current and Townsend firing discharge. However, in the characteristics for a cold cathode fluorescent lamp including ballast capacitors, the current increases as the voltage increases in the glow discharge region without representing a cathode fall since the most voltage is loaded at two capacitors. The characteristics for the external electrode fluorescent lamp shows the same as that of the cold cathode fluorescent lamp in the respect of glow discharge characters, and the external electrode itself roles the ballast capacitor.

Precision Electric Discharge Machining of a Cold Forging Die for Helical Gear Manufacturing (헬리컬기어 냉간단조 금형의 정밀방전가공)

  • Kwon J.J.;Joun B.Y.;Joun M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.158-161
    • /
    • 2005
  • In this paper, the precision electric discharge machining technology, the powder electric discharge machining technology, is applied to making a cold forging die for making the helical type of clutch gear. Various working conditions are investigated with emphasis on reduction of the electrode wear and enhancement of the surface roughness. Through the research work, the key technology of making the helical gear forging dies is achieved.

  • PDF

Effects of a Gelatin Coating on the Shelf Life of Salmon

  • Heu, Min-Soo;Park, Chan-Ho;Kim, Hyung-Jun;Lee, Dong-Ho;Kim, Jin-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • This study was conducted to investigate the efficacy of using a coating of gelatin extracted from refiner discharge to extend the shelf life of salmon during cold storage ($5^{\circ}C$). Relative percentage of moisture loss in gelatin-coated salmon during cold storage was less than that of uncoated salmon. The treatment of salmon with gelatin reduced volatile basic nitrogen (VBN) formation throughout the entire storage period. Measurements of the peroxide value (POV), fatty acid composition, and (20:5n-3+22:6n-3)/16:0 ratio during cold storage indicated that the coating of salmon with gelatin from refiner discharge effectively suppressed lipid oxidation over the entire storage period. The extent of sensory color change during cold storage was less in the gelatin-coated than in the uncoated salmon. From the results of chemical measurements, such as relative moisture content, VBN, POV, fatty acid composition, (20:5n-3+22:6n-3)/16:0 ratio, and sensory color change, the conclusion was made that the coating treatment of salmon with refiner discharge gelatin effectively suppressed moisture loss, lipid oxidation, and color deterioration over the entire storage period.

The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System (지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3))

  • Hahn, Jeongsang;Lee, Juhyun;Kiem, Youngseek;Lee, Kwangjin;Hong, Kyungsik
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water (수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험)

  • 최인수;김재돌;윤정인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

Experiment of Characteristic on the Charge and Discharge of Cold for In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 축방냉 특성)

  • Jang, Y.S.;Choi, I.S.;Moon, C.G.;Chun, S.H.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.268-273
    • /
    • 2001
  • A fundamental study on the harvest-type ice storage system applied ice making method in-water and its temperature characteristics in ice storage system was performed experimentally of the charge and discharge of cold. This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks.

  • PDF

A Study on the Development of Cold Forging Dies for Stainless Steel Sheet (SUS420) (스테인리스 강판(SUS420)의 냉간단조용 금형개발에 관한 연구)

  • 김엽래;김세환;유헌일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.877-885
    • /
    • 1995
  • Cold forging die for metal scissor is made by electric discharge machine. The impression of female die is made by electric discharge machine, the heat treatment is applied, and the impression is polished. When we forge goods by using this kind of die, the abrasion is severe and the crack occurs after forging about 240 strokes. Because the die should be frequently produced in the case, the cost rises, the work is delayed, and the precesion of goods is not good. Therefore, the electric discharge machine was not used in this study. Main die was produced by making hob, installing the hob to cold hobbing press, indenting the die material, and cold hobbing the impression. The die life was increased to 5,000-6,000 strokes in this case. In the future study, the die life will be increased to 10,000 strokes by changing the following : (1) the pre-treatment of slug, (2) the structure of die block, (3) the heat treatment of die material