• Title/Summary/Keyword: Discharge nozzle

Search Result 167, Processing Time 0.026 seconds

Wavenumber analyses of panel vibrations induced by transonic wall-bounded jet flow from an upstream high aspect ratio rectangular nozzle

  • Hambric, Stephen A.;Shaw, Matthew D.;Campbell, Robert L.
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.6
    • /
    • pp.515-528
    • /
    • 2019
  • The structural vibrations of a flat plate induced by fluctuating wall pressures within wall-bounded transonic jet flow downstream of a high-aspect ratio rectangular nozzle are simulated. The wall pressures are calculated using Hybrid RANS/LES CFD, where LES models the large-scale turbulence in the shear layers downstream of the nozzle. The structural vibrations are computed using modes from a finite element model and a time-domain forced response calculation methodology. At low flow speeds, the convecting turbulence in the shear layers loads the plate in a manner similar to that of turbulent boundary layer flow. However, at high nozzle pressure ratio discharge conditions the flow over the panel becomes transonic, and the shear layer turbulence scatters from shock cells just downstream of the nozzle, generating backward traveling low frequency surface pressure loads that also drive the plate. The structural mode shapes and subsonic and transonic surface pressure fields are transformed to wavenumber space to better understand the nature of the loading distributions and individual modal responses. Modes with wavenumber distributions which align well with those of the pressure field respond strongly. Negative wavenumber loading components are clearly visible in the transforms of the supersonic flow wall pressures near the nozzle, indicating backward propagating pressure fields. In those cases the modal joint acceptances include significant contributions from negative wavenumber terms.

Effect of the Pressure and the Flow Pattern in a Sac Chamber of a Diesel Injection Nozzle on the Issued Spray Behaviors (디젤 연료분사노즐 색크실내의 압력과 유동패턴이 분류의 분열거동에 미치는 영향)

  • 김장헌;송규근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • The effects of the internal flow in a diesel injection nozzle on the atomization of the spray has been investigated experimentally. Flow visualization was made using a transparent acrylic model nozzle. And also, measurement of the sac chamber pressure was made for clartfying the effect of pressure fluctuation in the sac chamber on the wpray behaviors. The geometry of the model nozzle was scaled up 10 times of the actual nozzle and the injection pressure for the model nozzle was adjusted so as to achieve a Reynolds number at the discharge hole which was the same as the actual nozzle. Polystyrene tracers, a laser sheet light and a still/high speed video camera were used to visualize the flow pattern in the sac chamber. When the needle lift was small, the high turbulence in the sac chamber generated by the high velocity seat flow made the spread angle of the spray large. Cavitation which arose in the sky chamber induced the pressure fluctuation and then affects the spread angle of the spray.

  • PDF

Effects of Nozzle Length-diameter Ratio on Internal and External Flow Characteristics of Biodiesel Fuel (노즐 형상비가 바이오디젤 연료의 노즐 내부 및 외부 유동 특성에 미치는 영향)

  • Park, Su-Han;Suh, Hyun-Kyu;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.94-100
    • /
    • 2007
  • The purpose of this work is to investigate the effect of properties of diesel and biodiesel fuels on the nozzle cavitation and the effect of the length/diameter(L/D) ratio on internal and external flow pattern of nozzle at the various injection conditions. In order to study the effect of the L/D ratio on the nozzle cavitation characteristics of diesel and biodiesel, the characteristics of cavitation flow in the nozzle are visualized and analyzed at the injection pressure of 0.1 MPa to 0.7 MPa by using the visualized images. It was founded that the cavitation was formed in the nozzle orifice at the low injection pressure and the breakup of the issuing liquid jet was promoted at the low L/D ratio. When the L/D ratio decrease, cavitation beginning and growth were affect by cavitation number and Reynolds number.

A Study for Development and Characteristics of Electrostatic Eliminator Suitable for the Super Clean Room Less than Class 100(I) (공기 청정지역(Class 100 이하)에 적합한 정전기 제거장치의 개발 및 특성에 관한 연구(I) - LCD 제조 공정을 중심으로 -)

  • Jung, Yong-Chul;Park, Hoon-Kyu;Lee, Dong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.60-65
    • /
    • 2006
  • It is a well known fact that LCD is a central part of the IT industry which is important in the present and the future. But the biggest problem of LCD manufacturing is maintaining a cleaning room environment and administration. Therefore the purpose of this study is to first, prevent the yield depreciation and damage of products, and second, protect the worker ftom accidental electrostatic discharge during LCD manufacture. The soft x-ray ionizer is a type of electrostatic reducer device. It protects against electrostatic discharge in the cleaning room environment and is a necessary environmental factor during LCD production. The positive aspects of the soft x-ray are its shorter time and wider angle of exposure. But the negative aspect of the soft x-ray is its need for several shielding of protection from the harmful x-ray exposure. On this study, the development of the Air Nozzle-type ionizer to amend and refine some problems. For example, examined the electrostatic reduce device of a soft x-ray type and discovered the ion did not go inside well. also workers to be free from danger. An Air Nozzle-type ionizer is comprised of soft x-ray radiation and ionized air production. Air is injected through the nozzle after being ionized from radiation. It supplies air keeping the same pressure into the end foundation of ion production. The soft x-ray is the structure which radiates ionized air through the nozzle (21 holes) having micro holes of the ionizable radiation after ionizing the inside air by the ion production. A worker does not need a cover to protect against x-rays and the Air Nozzle-type ionizer is easy to set up and is more effective at eliminating electrostatic.

A study on the high voltage nozzle type ozonizer (高電壓 nozzle 형 오존발생기에 관한 연구)

  • 송현직;이광식;이동인;조환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.1
    • /
    • pp.97-103
    • /
    • 1995
  • This paper reports the following two topics : $\circled1$ ozone concentration (O$\sub$3con/) and discharge characteristics in flowing O$\sub$2/ with variation of Re$\sub$3/ at high voltage nozzle (HVN) of HVN 10 type ozonizer. $\circled2$ O$\sub$3con/ with variation of Re$\sub$3/ at HVN of HVN 25 type ozonizer. The important conclusions obtained from this paper are as follows. 1) In HVN 10 type ozonizer : $\circled1$ The discharge pattern can be controlled by adjustment of the Re$\sub$3/. $\circled2$ V$\sub$c/ is inversely proportional to pulse width (P$\sub$w/) and pulse frequency (P$\sub$f) $\circled3$ O$\sub$3con/ increase as decreasing of Re$\sub$3/ for constant P$\sub$w/ and P$\sub$f/. $\circled4$ O$\sub$3con/ increase as decreasing of P$\sub$w/, O$\sub$3con/ is proportional to P$\sub$f/. 2) In HVN 25 type ozonizer : O$\sub$3con/ of HVN 25 type ozonizer can increase than that of HVN 10 type ozonizer, according to parallel circuit of applied voltage and serial of supplied gas. As a result, we can obtain O$\sub$3con/ of 825[ppm] as the maximun value.

Effects of Pressure and Temperature of Airflow on Performance of Nozzle-type Electrostatic Eliminator

  • CHOI Kwang-Seok;MOGAMI Tomofumi;SUZUKI Teruo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.228-232
    • /
    • 2005
  • The effects of the pressure and temperature of airflow were experimentally investigated to improve the performance of a nozzle-type electrostatic eliminator. The pressure ($A_P$) and the temperature ($A_T$) of the airflow toward the needle electrode were controlled in the ranges of 0 Mpa to 0.3 Mpa and of $25^{\circ}C$ to $125^{\circ}C$, respectively. It was confirmed that the ion-generation ability was increased depending on the magnitude of the $A_P$ and the $A_T$ of the airflow provided to the surrounding region of the needle electrode in the nozzle-type electrostatic eliminator. In addition, it was clear that the mixed effect of the $A_P$ and the $A_T$ of the airflow was large. These results were attributed mainly to (1) the activation of the corona discharge by the $A_T$, (2) the change of the decomposition and production of a suppression gas by the $A_T$, (3) the blow-off of the suppression gas near the needle electrode by the $A_P$, and (4) the change of the distribution of the current densities on the needle electrode by the $A_P$.

Large Eddy Simulation of Fluctuating Mold Level - Effects of Nozzle Geometry on Oscillation Frequency (LES를 이용한 몰드 내 탕면 변동 거동 수치해석 - 노즐 형상에 따른 진동 주파수 분석)

  • Lee, Kyongjun;Yang, Kyung-Soo;Cho, Myung Jong;Hwang, Jong-Yeon
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.2
    • /
    • pp.129-135
    • /
    • 2012
  • High speed casting technology is an attractive method to increase the productivity of continuous casting. However, high speed casting causes flow instability of molten steel in a mold. In this study, Large Eddy Simulation (LES) has been performed to identify the characteristics of mold flow for various shapes of submerged entry nozzles. The LES code has been newly developed to efficiently compute the two-phase flow by using the Fractional Step Method (FSM) combined with the Volume of Fluid (VOF) method. The Immersed Boundary Method was used to implement the shape of the submerged entry nozzle. Three cases of discharge angle of the submerged entry nozzle were computed and compared. The current results shed light on improving shape design of a submerged entry nozzle.

An Experimental Study on a Discharge Pressure, Flow Rate and Foam Discharge Concentration through the Nozzle According to the Foam Suction Nipple Diameter (노즐 구경에 따른 포 수용액의 압력과 유량 및 농도 변화에 관한 실험적 연구)

  • Jang, Kyung-Nam;Lee, Maing-Ro;Park, Bong-Rae;Yun, Ki-Jo;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.84-91
    • /
    • 2015
  • The purpose of this study is to suggest the reasonable model of the caliber in suction nozzle, the pressure of suction nozzle, and the flow rate about foam system of line proportioner type using in the pumpcar. To test this, the experimental study was accomplished on the ground of the standards for the Performance Certification and Product Inspection of Foam Fire-extinguishing Chemical Mixing Machine. Aqueous Film Forming Foam in 3% and pipe type air foam nozzle with line proportioner FE 40 type were used. Test result showed that the pressure of suction nozzle within the limits between 0.25 MPa and 0.35 MPa was appropriate when the caliber in suction nozzle is 4 mm. Also, the pressure of suction nozzle within the limits between 0.45 MPa and 0.60 MPa was appropriate in the higher pressure than 4 mm when the caliber in suction nozzle is 5 mm.

Evaluation of micro jet nozzle using finite elements method (유한요소해석을 이용한 마이크로 분사 노즐 특성 평가)

  • Lim, Dong-Wook;Choi, Doo-Sun;Kim, Tae-min;Park, Jung-Rae;Park, Kyu-Bag;Ham, Hwi-Chan;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • In the drug delivery system industry, the technology with even split injection becomes important for maximizing efficiency and minimizing the side effects. In conventional drug delivery system, infection can occur due to pain and splashing. Also, various applications are impossible due to disposable use, and it is the reason to avoid to use this system because of the complexity of the driving method. Therefore, in this study, a painless drug delivery device is developed for non-pain with electrical insulation breakdown method. Finite elements analysis was used to evaluate the ejection characteristics of drugs according to the shape of the micro ejection nozzle. The effect of the number of holes in the micro nozzle, the length of the nozzle and the inner shape of the nozzle on the drug discharge characteristics were analyzed.

A Fundamental Study of Thrust-Vector Control Using a Dual Throat Nozzle (이중목 노즐을 이용한 추력벡터 제어에 관한 기초적 연구)

  • Shin, Choon-Sik;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.339-342
    • /
    • 2010
  • Dual throat nozzle(DTN) is recently attracting much attention as a new concept of the thrust vectoring technique of propulsion jet. This DTN is designed with two throats, an upstream minimum and a downstream minimum at the nozzle exit, with a cavity in between the upstream throat and exit. In the present study, a computational work has been carried out to analyze the performance of a dual throat nozzle(DTN) at various mass flow rate of secondary flow. Two-dimensional, steady, compressible Navier-Stokes equations were solved using a fully implicit finite volume scheme. The present computational results were validated with some experimental data available. Based upon the present results, Thrust-vector control using a DTN is discussed in terms of the thrust coefficient and the coefficient of discharge.

  • PDF