• 제목/요약/키워드: Discharge limit

검색결과 180건 처리시간 0.026초

New methodologies to derive discharge limits considering operational flexibility of radioactive effluents from Korean nuclear power plants based on historical discharge data

  • Kang, Ji Su;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1003-1015
    • /
    • 2022
  • The new methodologies to derive discharge limits considering operational flexibility according to international safety standards were developed to help reduce the environmental releases of radioactive effluents from nuclear power plants (NPPs). To overcome the limitations of the two existing methods to set up discharge limits assuming a specific statistical distribution of the effluent discharge, two modified equations were newly proposed to directly derive a particular discharge limits corresponding to the target 'compliance probability' based on the actual annual discharge data for a specific NPP and radionuclide groups. By applying these to the actual yearly discharge data of 14 Korean NPPs for 7 radionuclide groups for the past 20 years, the applicability of two new methodologies to actual cases was demonstrated. The 'characteristic value' with approximately a 90% compliance probability for each Korean NPP and radionuclide group was proposed based on the results. The new approaches for setting up the discharge limits and the characteristic values developed in this study are expected to be effectively utilized to foster operator's efforts to progressively reduce the environmental releases of radioactive effluents of NPPs relative to the previous discharge data considering operational flexibilities.

고주파 전기회로의 개폐불꽃에 의한 LPG-공기 혼합가스의 최소점화한계전압에 관한 연구 (A Study on the Minimum Ignition Limit Voltages for LPG-Air Mixtures by Discharge Sparks in Radio-frequency Circuits)

  • 이춘하;김재욱;지승욱;송현직;이광식;이동인
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.79-84
    • /
    • 1998
  • 본 논문은 고주파 발생장치와 IEC형 불꽃점화 시험장치를 이용하여 라디오 주파수 범위내에서 발생하는 개폐불꽃에 의한 LPG-Air 5.25[Vol$\%$]의 혼합가스에 대한 최소점화한계전압을 구하였다. 그 결과 LPG-Air 혼합가스는 주파수가 높을수록 최소점화한계전압도 높아졌으며, 특히 3[KHz]에서 10[KHz]사이에서 현저히 증가함을 알 수 있었다. 이는 3[KHz]까지는 1회의 방전에너지에 의해 점화가 발생되지만 3[KHz]이상에서는 2회 이상의 방전에너지가 누적되어 점화가 일어남을 알 수 있었고 그 이유는 방전과 방전간의 휴지기간이 존재하므로써 생기는 에너지의 손실이 그 원인으로 생각된다. 본 연구결과는 가스가 존재하는 위험장소에서도 안전하게 사용될 수 있는 통신장비나 각종탐지기 등에 응용될 수 있는 본질안전 방폭형 고주파 전기기기의 연구개발을 위한 기본자료로서 뿐만 아니라 이들 장비의 방폭성능에 대한 시험자료로도 활용가능할 것으로 사료된다.

  • PDF

부분방전 신호 검출 시 노이즈 제거방법 (The Noise Removal Methode of Partial Discharge Signal)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1436-1441
    • /
    • 2016
  • Currently, partial discharge diagnosis in the field of prevention applied technology and diagnostic equipment is a possible strong limit to remove the noise generated by external or internal I still have one unreliable diagnosis. This technology is the noise removal from signal the time lag analysis algorithms technique is applied by a fundamental. Increasing the reliability in terms of technology spectrum frequence of analysis method for by applying the acquisition through the position of the frequency content and sources of traffic lights partial discharge of the acquisition of signal analysis to judge whether a way diagnosis the environment of the scene, and conditions. Partial discharge signal and make the discharge while building blocks were found through the Analysis. Spectrum frequence of Analysis and wide discharge part, to be more precise, in line with the various functions, including the analysis technique band. Diagnosis and comes up with advanced technology that can detect the presence of a position. This method is portable single device developed for maintenance and mobility and ease and convenience of getting caught by discharge of the pattern analysis and position detection method suitable for a new diagnosis will suggest.

저항회로의 개폐불꽃에 의한 폭발성 가스의 점화한계에 관한 연구 (A Study on The Ignition Limit of Flammable Gases by Discharge Spark of Resistive Circuit)

  • 이춘하
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.106-112
    • /
    • 1997
  • 본 연구는 직류 저항회로의 개폐불꽃에 의한 폭발성 가스의 점화한계를 실험적으로 고찰하였다. 실험은 IEC형 불꽃점화 시험장치의 폭발용기에 폭발성 가스(메탄-공기 프로판-공기, 에틸렌-공기, 수소-공기)를 각각 넣고 텅스텐 전극과 카드뮴 전극사이에서 발생하는 3,200회의 개폐불꽃에 의한 점화유무를 확인하므로서 점화한계를 구하였다. 또한 실험장치의 점화감도교정을 실험한 후에 실시하므로서 실험의 정확성을 기하였다. 실험결과 최소 점화 전류값을 갖는 최소점화한계농도는 메탄-공기 8.3 [$Vol\%$], 프로판-공기 5.25[$Vol\%$], 에틸렌-공기 7.8[$Vol\%$], 수소-공기 21[$Vol\%$]로서 기존의 실험결과와 유사한 결과를 나타내었다. 또한 최소점화한계농도에서 전압과 최소점화잔류와의 관계를 구한 결과 최소점화한계는 메탄, 프로판, 에틸렌, 수소가스의 순서로 낮아졌고 점화전류의 크기는 전원전압의 크기와 반비례하고, 전극의 과열현상으로 인하여 전압 약 20(V)이하에서는 최소점화전류가 2(A)를 넘으면서 심화한계곡선이 급격히 상승한다는 것 등을 알 수 있었다.

  • PDF

소형 소닉 노즐의 유출계수에 관한 실험적 연구 (An Experimental Study on the Discharge Coefficients of Small Sonic Nozzles)

  • 차지선;박경암;최용문;최해만;윤복현
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.44-49
    • /
    • 2000
  • Small sonic nozzles (throat diameter $0.28{\~}4.48mm$) were tested in the gas flow standard system. This standard system is composed of two bell provers and 5 column piston provers, compressor, filters, and dehumidifier. The discharge coefficients of small some nozzles are obtained and correlated as a function of throat Reynolds numbers with $0.316\%$ uncertainty at a confidence level $95\%$. The tested high Reynolds number was the lower limit of ISO 9300 specifications. The data are useful as data base for revision of ISO 9300.

  • PDF

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

다채널 대용량 충방전기 모듈 개발에 대한 연구 (A Study on the Multi-Channel Large Capacity Charge/Discharge Formation Module)

  • 이준하
    • 반도체디스플레이기술학회지
    • /
    • 제15권2호
    • /
    • pp.55-60
    • /
    • 2016
  • This study was developed through the secondary battery module charging/discharger possible utilization in the production process equipment circuit. The developed module is ensuring construction of efficient and productive charging and discharger through this research a limit on the yield and the price of existing single -channel charge and discharger circuit as a 5V 70A grade secondary battery Formation charge and discharger for up to 1 board 4 channels. In order to improve the sensing accuracy, through a robust differential amplifier circuit described using 16bit Analog-Digital Converter and noise was secured 16bit resolution sensing. The configuration also made demands for property Rise / Fall Time. Data Acquisition, discharge efficiency and also to fit the sink circuit temperature level for mass production.

정적연소에서 점화에너지와 당량비와 유동과의 관계 (Relations Among Discharge Energy, Equivalence Ratio and Turbulent Intensity at a Constant Volume Combustion)

  • 이중순;이태원;이상석;하종률
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2308-2315
    • /
    • 1995
  • We studied the effects on the ignitability of mixture, the combustion duration, and the maximum combustion pressure, of various initial combustion factors such as temperature, pressure, and each equivalence ratio in order to identify the combustion characteristics of lean mixture and improve ignitability through the proper control of the ignition energy. It is concluded that there is an optimum turbulent intensity that enables the combustion to have the best ignitability and the shortest duration under each equivalent ratio, and the combustion duration is only dependent upon the distribution and magnitude of discharge energy within the limit of inflammability.

고주파 전기회로의 개폐불꽃에 의한 LPG-공기 혼합가스의 점화한계에 관한 연구 (A Study on the Minimnum Ignition Limit for LPG-Air Mixtures by Switching Sparks in Radio-frequency Circuits)

  • 지승욱;송현직;이춘하;박원주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1854-1856
    • /
    • 1996
  • This study describes the minimum ignition limit for LPG-Ai-r mixtures by switching sparks in radio-frequency limits using RF power supply and IEC type ignition spark apparatus. As a result, the minimum ignition limit voltage is increased in proportional to the rate of increasing of frequency in LPG-Air mixed gas. Especially, increment between 10[kHz] and 30[kHz] is typical. It is considered that ignition is caused by one discharge until 10 [kHz] and, beyond 10[kHz] ignition is caused by more than two discharges. The reason is analysed that energy loss is caused by existing pause interval between discharges.

  • PDF

Hydroxypropyl Methyl Cellulose의 분진 폭발특성에 관한 연구 (A Study on Dust Explosion Characteristics of Hydroxypropyl Methyl Cellulose)

  • 임우섭;목연수
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.95-100
    • /
    • 2000
  • This study was performed in Hartmann type dust explosion apparatus in order to research the dust explosion characteristics of hydroxypropyl methyl cellulose(HPMC): minimum explosive limit, minimum ignition energy, limiting oxygen concentration, maximum explosion pressure, rate of pressure rise, etc. The samples of HPMC dust were distributed into 120-140 mesh, 170-230 mesh and 325 under, and the gap distance of the discharge electrode was setted up at 5mm. The experimental results were obtained as follows: (1) The minimum explosive limit for HPMC dust was founded at 180g/㎥. the minimum ignition energy at 9.8mJ and the limiting oxygen concentration at 12%. (2) The maximum explosion pressure of HPMC dust was $8.1kg/cm^2\;{\cdot}\;$abs at the concentration of $500g/m^3$ and the maximum rate of pressure rise was 203.98 bar/sec at the concentration of $480g/m^3$ for 325 under.

  • PDF