• Title/Summary/Keyword: Discharge limit

Search Result 179, Processing Time 0.035 seconds

Construction of Current Sensor Using Hall Sensor and Magnetic Core for the Electric and Hybrid Vehicle (홀소자와 자기코어를 이용한 하이브리드 및 전기자동차용 전류센서 제작)

  • Yeon, Kyoheum;Kim, Sidong;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.49-53
    • /
    • 2013
  • A current sensor is one of important component which is used for the electrical current measurement during charge and discharge of the battery, and monitoring system of the motor controller in the electric and hybrid vehicle. In this study, we have developed an open loop type current sensor using GaAs Hall sensor and magnetic core has an air gap. The Hall sensor detect magnetic field produced by the current to be measured. The 3 mm air gap core was made by HGO electrical steel sheets after slitting, winding, annealing, molding, and cutting. Developed current sensor shows 0.03 % linearity within DC current range from -400 A to +400 A. Operating temperature range was extended to the range of $-40{\sim}105^{\circ}C$ using temperature compensating electronic circuit. To Improve frequency bandwidth limit due to the air flux of PCB (Printed Circuit Board) and Hall sensor, We employed an air flux compensating loop near Hall sensor or on PCB. Frequency bandwidth of the sensor was 100 kHz when we applied sine wave current of $40A{\cdot}turn$ in the frequency range from 100 Hz to 100 kHz. For the dynamic response time measurement, 5 kHz square wave current of $40A{\cdot}turn$ was applied to the sensor. Response time was calculated time reach to 90 % of saturation value and smaller than $2{\mu}s$.

Effect of Operating Conditions of UASB Reactor on Biodegradation of C. I. Reactive Blue 114 (C. I. Reactive Blue 114의 분해에 미치는 혐기성 UASB 반응기 운전조건의 영향)

  • Oh, You-Kwan;Lee, Sung-Ho;Kim, Hyo-Seob;Park, Tae-Joo;Park, Sung-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.619-627
    • /
    • 2000
  • Biodegradation of the C. I. Reactive Blue 114 was investigated in an upflow anaerobic sludge blanket (UASB) reactor. Important parameters studied include dye concentration, the kind and concentration of carbon source, hydraulic retention time (HRT), and influent pH. Glucose was found to be a better co-substrate than the mixture of volatile fatty acids (VFAs), although its concentration did not affect dye removal efficiency in the range of $1000{\sim}3000mg/{\ell}$. When HRT increased from 6 hr to 24 hr, dye removal efficiency increased up to 12 hr and remained almost constant thereafter at about 40%. When influent pH was varied in the range of 6.0~8.0, the effluent pH was varied in the range of 6.8~7.5 with maximum efficiency at pH 7.0. The highest dye removal rate obtained was $52mg/{\ell}{\cdot}day$, while the maximum dye load to meet the discharge limit of color intensity was estimated to be $46mg/{\ell}{\cdot}day$ at HRT of 12 hr and an influent glucose concentration of $2200mg/{\ell}$.

  • PDF

DISTRIBUTION CHARACTERISTICS OF NUTRIENTS IN CHINESE BOHAI SEA

  • Li, Zhengyan;Gao, Huiwang;Bai, Jie;Shi, Jinhui
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2001.11a
    • /
    • pp.19-29
    • /
    • 2001
  • Nutrients are key environmental factors in marine ecosystem. They limit algal growth when at low concentrations and cause algal bloom when at high contents. They also control the growth and succession of many other biota including bacteria and zooplankton, either directly or indirectly. Nutrient contents therefore affect both the structure and functions of marine ecosystem. To study the contents and distribution of nutrients in Chinese Bohai Sea, two cruise surveys were undertaken in August 2000 (summer) and January 2001 (winter), respectively. A total of 595 water samples were collected from 91 sites. After collection the samples were transported to the laboratory and five nutrients, i.e., nitrate, nitrite, ammonia, phosphate and silicate, were analyzed. The results showed that tile average concentration of total inorganic nitrogen (TIN) in Bohai Sea in winter (6.5293.717 ${\mu}$mol$.$l$\^$-1/) was significantly higher than that in summer (3.717 ${\mu}$mol$.$l$\^$-1/). The phosphorus concentration in winter (0.660 ${\mu}$mol$.$l$\^$-1/) was also significantly higher than that in summer (0.329 ${\mu}$mol$.$l$\^$-1/). Mean silicate concentration in winter (7.858 ${\mu}$mol$.$l$\^$-1/) was not significantly different from that in summer (7.200 ${\mu}$mol$.$l$\^$-1/). Nutrients also varied considerable among different areas within Bohai Sea. TIN concentration in Laizhou Bay (4.444 ${\mu}$mol$.$l$\^$-1/), for example, was significantly higher than those in Bohai Bay (2.270 ${\mu}$mol$.$l$\^$-1/) and Bohai Straight (2.431 ${\mu}$mol$.$l$\^$-1/), which probably reflects tile discharge of large amounts of nitrogen into Laizhou Bay via Yellow River. The nutrients also showed vertical distribution pattern. In summer, nutrients in bottom layer were generally higher than those in surface and medium layers. In winter, however. nutrients in different layers were not significantly different Compared with historic data, TIN contents increased continuously since early 1980s, phosphorus arid silicone contents, nevertheless, fell down to some degree. Based on atomic ratios of different nutrients, nitrogen is still the main limiting factor for algal growth in Bohai Sea.

  • PDF

Estimation of Water Quality Environment in Youngsan and Seumjin River Basins (영산강과 섬진강 유역의 하천 수질환경 평가)

  • 양해근;최희철
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.1
    • /
    • pp.16-31
    • /
    • 2003
  • The water quality environment in Youngsan and Seumjin river basins was investigated based on the concept of the comprehensive Water Quality Index (WQI) and a spacial pollution source. Artificial factors influencing to river water quality have been analyzed. The specific delivery load of Youngsan river basin was found to be 8.34~97.25 kg/day/$\textrm{km}^2$, Gomagwon stream and Gwangju stream showed the relatively high rates as 97.25 kg/day/$\textrm{km}^2$ and 86.06 kg/day/$\textrm{km}^2$, respectively. The specific delivery load in Seumjin river basin was estimated to be 10.98∼19.51 kg/day/$\textrm{km}^2$, Suggesting no Significant Contribution of pollution. WQI of Youngsan watershed revealed 1.36~3.45, whereas Seumjin watershed showed a relatively low value of 0.5~1.47 And it is concluded that the specific delivery load suggested in this study provides the essential core data of the upper limit of pollutants receptor in the watershed area studied. From this study, it is suggested that the integrated environmental management of river basin requires the analysis of pollutants generation rate of the basin and the receptor capability for the self-purification.

A Study on the Management Method of Agricultural reservoir Using RCP Scenario (RCP 시나리오 분석을 통한 농업용 저수지 관리방안에 관한 연구)

  • Choo, Yeon Moon;Won, Chang Hee;Kim, Seong Ryul;Gwon, Chang Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 2020
  • A reservoir is defined as an artificial facility that stores and controls water during floods and droughts. Korea has constructed and managed reservoirs all over the country to benefit farming communities. The importance of reservoirs has decreased gradually due to urbanization and the spread of tap water, but the importance of water is increasing because of the recent shortage of water and the resulting rise in the price of water resources. Therefore, this study suggests countermeasures through an analysis of the used threshold for agricultural reservoirs. To this end, the forecast of rainfall up to 2100 was first analyzed using flood estimates and RCP scenarios through rainwater data collection. The increase in the RCP 8.5 scenario, the largest increase in the probability rainfall, was calculated by adding it to the current probability rainfall, and it was predicted that the marginal height of Odong Dam would reach its limit in 2028. Therefore, as a countermeasure against this, the measures to secure effective water storage were suggested through measures, such as lowering the height of Yeosu and installing movable beams. Overall, it is expected that effective management of the reservoirs used for agriculture will be possible in the future.

Algal Growth Potential Test (AGPT) in the Stream- Reservoir System of the Pyeongtaek Reservoir Watershed, Korea (평택호와 유역 하천에서 조류생장잠재력측정)

  • Hwang, Soon-Jin;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.2 s.103
    • /
    • pp.172-180
    • /
    • 2003
  • For a biological assessment of Pyeongtaek Reservoir and its major influent streams, an algal growth potential test (AGPT) was conducted with the blue-green algae Microcystis aeruginosa in March, June, September and December, 2000. The range and average value of AGPT were from 0 to 463 mg dw/l and 90 mg dw/l, respectively. For the influent streams in particular, the average of AGPT was the in the Hwangguchi Stream (343 mg dw/l). It decreased to 158, 66, 29, 21, and 21 mg dw/l in the Sojong Stream, Songhwan Stream, Osan Stream, Chinwi Stream, and Ansong Stream, respectively. The AGPT values in the reservoir ranged from 0 to 138 mg dw/1(mean 54 mg dw/1) with a tendency to increase in the upstream, which was close to the influent streams. In general, the AGPT values decreased further in the downstream. Immediately after the abrupt increase in influent discharge in summer, the AGPT value in the downstream almost doubled due to the proliferation of blue-green algae. The water quality of Pyeongtaek Reservoir and its influent streams further deteriorated during the drought period. Similarly, the AGPT value was the highest during this period. The AGPT values showed the closest correlation with the content of P (r = 0.999, p<0,001). Thus, it could be concluded that the content of P is highly effective in the growth of algae. In the Pyeongtaek Reservoir Watershed, the AGPT values varied in space and time. It was also closely related to the nutrient content of influent streams. The AGPT values revealed that the water quality state was hypertrophic (> 20 mg dw/1). Thus, control of the aquatic environment is essential. AGPT is very useful in evaluating the fertility and pollution state of the water as well as determining the nutrients that limit the growth of algae.

Migration Patterns of Brachymystax lenok tsinlingensis Using Radio Tags in the Upper Part of the Nakdong River (Radio tag을 이용한 낙동강 상류에 서식하는 열목어의 이동양상)

  • Yoon, Ju-Duk;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.58-66
    • /
    • 2009
  • The telemetry of eight adult manchurian trouts (Brachymystax lenok tsinlingensis) in the upper part of the Nakdong River, which is the southern limit of distribution of manchurian trout on the Korean peninsula, was used to examine migration patterns and evaluate characteristics of over-wintering and the spawning season between December, 2007 and May, 2008. Based on the tracking data, the tagged fish showed a limited migration between adjacent pools, moving only up to $8.6m\;day^{-1}$ during the winter season (December to February). Hydraulic conditions of over-wintering pool areas were, ca. 1m depth, slow moving surface water with areas of sand and gravel. The migration of tagged individuals was successful, moving up to $96.2m\;day^{-1}$ during the spawning season. Two tagged individuals (BL4, BL6) exhibited upstream migration, whereas others showed downstream movements. The timing of upstream migration of the two individuals was consistent with an increasing phases of water level and discharge. The fishes migrating toward the down stream moved to the wide pool areas downstream, where they spent the summer season for the growth.

Selective Nitrate Removal Performance Analysis of Ion Exchange Resin in Shipboard Waste Washwater by Air Pollution Prevention Facility (선박용 대기오염장치 폐세정수 내 질산염의 선택적 제거를 위한 이온교환수지 공정 성능 평가)

  • Kim, Bong-Chul;Yeo, In-Seol;Park, Chan-Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.399-404
    • /
    • 2021
  • From 1 January 2020, the limit for Sulphur in fuel oil used on board ships operating outside designated emission control areas will be reduced to 0.5 %. This regulation by international maritime organization (IMO) is able to significantly reduce the amount of Sulphur oxides (SOx) discharging from ships and should have environmental advantages and health for all over the world. To meet the regulation, in these days, wet scrubber system is being actively developed. However, this process leads to make washing wastewater. In this study, we evaluated ion exchange resin system in accordance with scrubber wastewater discharge regulation by IMO. Theoretical wastewater used as feed solution of lab scale water treatment systems. The results revealed that nitrate ion was removed selectively in spite of high TDS wash wastewater solution depending on ion exchange resin property. Moreover, it was possible to improve efficiency of the system by optimizing operating conditions.

Numerical Study on Performance of PEMFC with Block and Sub-channel of Cathode Flow Field (캐소드 유로에서 블록과 서브 채널의 고분자전해질 연료전지의 성능에 관한 전산해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.613-620
    • /
    • 2021
  • A flow channel shape of PEMFC has an influence on the internal flow uniformity. If the reactant distribution in a flow path is not uniform during operation, both catalyst deactivation and mechanical damage of membrane could occur resulting in decreasing the membrane electrode assembly (MEA) durability. Numerous studies concerning flow design have been conducted to make smooth supply and uniform distribution of reactants in fuel cells. The baffle of flow path could improve fuel cell performance through the forced convection effect. A sub-channel, as an additional air flow path, could increase the reactant concentration and reduce the mass transfer loss via a smooth water discharge. In this study, computational fluid dynamics (CFD) was used to analyze the effect of blocks and sub-channels on the current density and oxygen concentration of the fuel cell. As a result, the limit current density and oxygen concentration at a rear block increased when using blocks and sub-channels in a flow channel. In particular, the current density increased significantly when the sub-channel was placed between two blocks. Also, the sub-channel position was optimized by analyzing the oxygen concentration, and the oxygen concentration was recovered at a rear block in the fuel cell.

Investigations of the External Dose Rate (${\mu}Sv/h$), the Residual Activity (mCi) and the Excretion Rate (%) of Thyroid Cancer Patients Hospitalized for 3700 MBq (100 mCi) $^{131}I$ Radioiodine Treatment ($^{131}I$ 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(${\mu}Sv/h$), 잔류량(mCi), 배설률(%) 측정)

  • Bae, Gi-Han;Kim, Hwa-Joong;Choi, Jae-Jin;Lee, Won-Guk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2009
  • Purpose: As Korean nuclear law doesn't have any clear guideline about the dose and the external dose rate(uSv/h) requiring hospitalization in radioactive iodine treated patients, the patients are discharged when they meet the guideline of IAEA Basic Safety Standards(BSS). We measured external dose rate(${\mu}Sv/h$) of inpatient underwent 3700MBq (100 mCi) $^{131}I$ radioiodine treatment and considering external dose rate(${\mu}Sv/h$), residual activity(mCi) and excretion rate(%) we found the time for RA to be lowered from 3700MBq (100 mCi) to 1110 MBq (30 mCi) to give reference to set a guideline for discharge. Materials and Methods: Forty-two patients underwent thyroidectomy and scheduled for radioiodine treatment, who received 3700MBq (100 mCi) of $^{131}I$ orally and had no renal disease were examined. After 1, 2, 4, 8, and 20, 24, 40 hours iodine uptake and before/after the urination, the external dose rate(${\mu}Sv/h$) measured using FH40G-L(Thermo Fisher Scientific Inc., MA) at a distance and a height of 1 m for 20 sec on the average. Results and Conclusions: At 20 hours, the external dose rate was decreased to $49{\pm}13\;{\mu}Sv$/h, namely, 78% of administrated radioactivity was excreted and 814 MBq (30 mCi) was residual, and it met the accepted limit for discharge of (IAEA, BSS) under 1110 MBq (30 mCi) (1 m at 66 uSv/h).

  • PDF