• 제목/요약/키워드: Discharge limit

검색결과 180건 처리시간 0.026초

Special monitoring results for determination of radionuclide composition of Russian NPP atmospheric releases

  • Vasyanovich, Maxim;Vasilyev, Aleksey;Ekidin, Aleksey;Kapustin, Ivan;Kryshev, Alexander
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1176-1179
    • /
    • 2019
  • Measurements of activity concentrations of radionuclides in atmospheric releases were performed in 2017-2018 at vent stacks of seven Russian nuclear power plants. The selected instruments and research methods, with detection limits significantly lower than the existing detection limit of Russian NPPs routine control, allowed to reliably determine up to 26 radionuclides. Analysis of experimental data allows to determine the list of radionuclides for calculation the effective dose rates to public and the permissible annual discharge levels for each Russian NPP. Radiocarbon is determined as major contributor for the dose from the atmospheric releases of LWGR reactors - up to 98% for EGP-6 and RBMK-1000 (Smolensk NPP) reactors. For PWR reactors (VVER) radionuclides contribution to the annual dose from atmospheric releases is more complicated, but, in general, dose is formed by tritium, $^{14}C$ and noble gases. The special monitoring results with ranking of measured radionuclides according to their contribution to the effective dose makes it possible to optimize the list of controlled radionuclides in airborne releases of Russian NPPs from 94 to 8-16 for different NPPs.

Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구 (Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change)

  • 황준환;박성영
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

연안해수와 지하해수를 사용하는 제주 넙치 양식장의 수질과 미생물 변동 (Investigation of water qualities and microbials on the flow-through olive flounder, Paralichthys olivaceus farms using coastal seawater and underground seawater in Jeju)

  • 김유희
    • 수산해양기술연구
    • /
    • 제58권1호
    • /
    • pp.59-67
    • /
    • 2022
  • This study assessed the levels of water qualities and microbials contamination of inland olive flounder farms in Jeju in the summers from 2015 to 2017. Three farms (A-C) located in a concentrated area using mixing coastal seawater and underground seawater and one farm (D) located in an independent area using only coastal seawater were selected. Total ammonia nitrogen (TAN) reached a maximum of 0.898 ± 1.024 mg/L as N in the coastal seawater of A-C, which was close to the limit of the water quality management goal of the fish farm. TAN in the influent from A-C was up to three times higher than that of D, so that the discharged water did not spread to a wide range area along the coast and continued to affect the influent. TAN of the effluent in A-C increased by 2.7-4.6 times compared to the influent, resulting in serious self-pollution in the flounder farm. Heterotrophic marine bacteria in the influent of A-C was about 600 times higher than D, and the discharge of A-C was increased by about 30 times compared to the influent.

엔트로피 지수를 이용한 기계학습 기반의 배터리의 건강 상태 예측 알고리즘 (Machine Learning Based State of Health Prediction Algorithm for Batteries Using Entropy Index)

  • 김상진;임현근;장병훈;우성민
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.531-536
    • /
    • 2022
  • 배터리를 효율적으로 관리하기 위해서는 배터리의 건강 상태와 잔여 수명을 정확하게 추정하고 관리하는 것이 중요하다. 배터리는 같은 종류여도 설비용량 및 전압 등의 특성이 다르며 학습용 모델을 위한 배터리와 모델을 통한 예측을 위한 배터리가 서로 다를 경우에는 정확도 측정에 한계가 있다. 본 논문에서는 전압의 분포와 방전 시간을 이용한 엔트로피 지수를 일반화하고 4개의 배터리를 각각 1개씩 교차적으로 훈련 집합과 테스트 집합으로 정의하여 기계학습의 선형회귀 분석을 통하여 배터리의 건강 상태를 예측하는 방법을 제안하였다. 제안된 방법은 평균 절대값 퍼센트 오차를 이용하여 95% 이상의 높은 정확도를 나타내었다.

Cranial Base Reconstruction and Secondary Frontal Advancement for Meningoencephalocele Following LeFort III Osteotomy in a Patient with Crouzon Syndrome: Case Report

  • Sungmi Jeon;Yumin Kim;Ji Hoon Phi;Jee Hyuk Chung
    • Archives of Plastic Surgery
    • /
    • 제50권1호
    • /
    • pp.54-58
    • /
    • 2023
  • Patients with Crouzon syndrome have increased risks of cerebrospinal fluid rhinorrhea and meningoencephalocele after LeFort III osteotomy. We report a rare case of meningoencephalocele following LeFort III midface advancement in a patient with Crouzon syndrome. Over 10 years since it was incidentally found during transnasal endoscopic orbital decompression, the untreated meningoencephalocele eventually led to intermittent clear nasal discharge, frontal headache, and seizure. Computed tomography and magnetic resonance imaging demonstrated meningoencephalocele in the left frontal-ethmoid-maxillary sinus through a focal defect of the anterior cranial base. Through bifrontal craniotomy, the meningoencephalocele was removed and the anterior cranial base was reconstructed with a pericranial flap and split calvarial bone graft. Secondary frontal advancement was concurrently performed to relieve suspicious increased intracranial pressure, limit visual deterioration, and improve the forehead shape. Surgeons should be aware that patients with Crouzon syndrome have the potential for an unrecognized dural injury during LeFort III osteotomy due to anatomical differences such as inferior displacement and thinning of the anterior cranial base.

물류창고 시설의 인명안전기준 개선 방안에 관한 연구 (A Study on the Improvement of Life Safety Code for Logistics Warehouse Facilities)

  • 김윤성;진승현;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2021
  • The number of fires in the Korean distribution warehouse increased by about 350 from 1,070 in 2014 to 1,416 in 2020. In addition, the fire load increases with the scale of the distribution warehouse, and even if the automatic sprinkler operates, there is a limit to the direct intrusion of the water source into the ignition source, and the detector is often installed on a high ceiling. The sensing time is often delayed. In order to improve the fire safety of such distribution warehouses, the US NFPA stipulates in detail the contents related to the facility, such as sprinkler water discharge standards, rack-type warehouse installation height restrictions, and regulations on collection and equipment. However, in Japan, the goods loaded inside the distribution warehouse are not classified in detail, and it is considered that the fire safety for the distribution warehouse is low due to the relaxation regulations of the fire prevention section. Therefore, in this study, common problems are classified into material, spatial, and safety management characteristics through the cases of distribution warehouse fires that occurred in Korea and abroad, and the problems related to distribution warehouses in Korea and abroad are compared and analyzed. And present basic materials for improving the life safety standards of future distribution warehouse facilities.

  • PDF

단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산 (Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve)

  • 최귀열
    • 한국농공학회지
    • /
    • 제7권1호
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

금강수계 내 환경기초시설 운영실태에 관한 연구 (A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System)

  • 이재운;박동기;권영호
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.

개구부 면적이 $CO_2$ 소화설비의 소화성능에 미치는 영향 -기계실 석유 표면화재의 CFD simulations- (The Effects of the Area of Openings on the Performance of a $CO_2$ Extinguishing System -The CFD Simulations of the Oil Surface Fire in a Machine Room-)

  • 전흥균;최영상;박종탁
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2008
  • 이산화탄소는 다른 어떤 가스계 소화약제보다도 화재를 안전하게 진압하는 소화약제로서 다양한 방호구역과 화재에 대하여 널리 사용되고 있다. 성능위주설계 개념에 따라 이산화탄소 소화설비는 설계 단계에서 해당 방호구역의 발생 가능한 화재시나리오에 따라 소화성능을 확인할 필요가 있다. 본 연구에서는 $100m^3$의 체적을 갖는 기계실의 석유 유출(설계)화재시 개구부의 크기가 $CO_2$ 소화설비의 소화성능과 유동장의 유동특성에 미치는 영향을 조사하기 위하여 CFD 시뮬레이션을 수행하였다. 소화완료 시간은 개구부의 면적 크기에 비례하여 증가하였고, 3가지 화재모델의 소화완료 시간 모두 $CO_2$ 소화설비의 성능기준에 부합하였다. 개구부의 질량 유동율은 화재 열방출과 $CO_2$ 소화약제 분사의 복합적인 작용에 의해 영향을 받았다. $CO_2$ 소화약제 분사 완료 후 방호구역의 산소농도는 화재모델 모두 연소한계산소농도 보다 적었다.

충주댐 방류에 따른 댐 상하류 홍수위 영향 분석 (Effect of Chungju Dam Operation for Flood Control in the Upper Han River)

  • 김상호;김지성
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.537-548
    • /
    • 2013
  • 본 연구에서는 2006년 홍수시 충주댐 운영에 따른 댐 상 하류의 홍수위 상승영향을 정량적으로 분석하기 위하여 팔당댐 상류의 한강 본류에 위치한 충주댐을 기준으로 상류구간과 하류구간으로 구분하고, 1995년부터 2008년까지의 홍수사상을 대상으로 모형을 검보정함으로써 수리학적 모형을 구축하였다. 구축된 모형을 이용하여 충주댐의 유무를 가정하여 충주댐의 홍수조절효과를 검토하고, 방류량의 변화에 따른 상 하류 주요지점의 수위 상승영향을 정량적으로 분석하였다. 분석결과, 2006년 홍수시 충주댐의 운영이 비교적 적절하게 수행되었음을 확인하였으나, 충주댐의 홍수조절효과는 댐 하류구간에 집중되어 있어 댐 상류 홍수피해 저감을 위한 제도적 보완이 필요한 것으로 분석되었다. 이러한 문제점을 해결하기 위하여 기존 댐 배수구간 상류 하천의 기점수위 결정방법의 한계를 검토하였으며, 댐 배수구간과 상류 하천의 계획홍수량 불연속을 반영할 수 있는 기점수위 결정방법을 제안하였다. 제안된 방법은 댐 상류하천의 홍수피해 저감을 위한 설계 및 홍수피해 발생시 피해원인 분석에 활용될 수 있을 것이다.