• 제목/요약/키워드: Discharge in liquid

검색결과 337건 처리시간 0.024초

절연유체 내 2상유동을 고려한 뇌임펄스 응답 유한요소해석 (Finite Element Analysis for Dielectric Liquid Discharge under Lightning Impulse Considering Two-Phase Flow)

  • 이호영;이종철;장용무;이세희
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2097-2102
    • /
    • 2011
  • Discharge analysis technique for dielectric liquid was presented by using the Finite Element Analysis (FEA) under a lightning impulse incorporating two-phase flow phenomena which described gas and liquid phases in discharge space. Until now, the response of step voltage has been extensively explored, but that of lightning impulse voltage was rarely viewed in the literature. We, therefore, developed an analyzing technique for dielectric liquid in a tip-sphere electrode stressed by a high electric field. To capture the bubble phase, the Heaviside function was introduced mathematically and the material functions for the ionization, dissociation, recombination, and attachment were defined in liquid and bubble, respectively. By using this numerical setup, the molecular dissociation and ionization mechanisms were tested under low and high electric fields resulted from the lightning impulse voltage of 1.2/50 ${\mu}s$. To verify our numerical results, the velocity of electric field wave was measured and compared to the previous experimental results which can be viewed in many papers. Those results had good agreement with each other.

기체주입식 분사기의 이상유동 변화와 분무특성에 관한 연구 (A Study on the Two-Phase Flow Transition and Atomization Characteristics in Effervescent Injectors)

  • 이강영;정하동;강철웅;안규복
    • 한국분무공학회지
    • /
    • 제27권3호
    • /
    • pp.144-154
    • /
    • 2022
  • Gas injection is a technique applied to improve throttling in liquid rocket engines and atomization in effervescent injectors. When a gas is injected into a liquid, it creates a two-phase flow inside the injector. The changes (bubbly flow, slug flow, annular flow, etc.) in the two-phase flow affect the injector's spray characteristics. In this study, cold-flow tests were performed by using three injectors with different orifice diameters and four aerators with different gas injection hole diameters. The experiments were done by changing the thrust ratio (liquid mass flow rate ratio) and gas-liquid mass flow rate ratio. Two-phase flow transition, breakup length, and discharge coefficient according to the injector/aerator design and flow conditions were investigated in detail.

Partial Discharge Measurements of Artificial Defects in HTS Transformer Model using HFCT

  • Lee, S.H.;Shin, W.J.;Park, T.G.;Koo, J.Y.;Lee, B.W.
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2009
  • Partial discharge measurements in cryogenic dielectric materials of HTS transformer are very important because partial discharge was regarded as primary source for ageing and breakdown of cryogenic materials. But, partial discharge measurement techniques and its effects in low temperature high voltage environments were not suggested and there exist only a few reports on this research fields. Therefore, in order to implement reliable HTS transformers, partial discharge diagnosis techniques for cryogenic materials of HTS transformers were investigated using partial discharge (PD) pattern analysis methods. In this works, four different types of artificial defects including turn to turn insulation, free moving particle, void and protrusion, have been fabricated since it was commonly regarded that they might cause the sudden service failures of the power apparatus. For this purpose, these defects are installed into the dielectric materials in liquid nitrogen and experimental investigations have been carried out for the diagnosis of HTS transformer. And various PD patterns caused by the amount of quench of superconductors were analyzed. Throughout this works, the different PD patterns in cryogenic dielectric materials in liquid nitrogen, and PD measuring technique could be the fundamental steps to establish diagnosis technologies of HTS transformer for power applications.

  • PDF

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

작동 조건에 따른 이중 와류 분사기 유량 계수 변화 연구 (Study on Discharge Coefficient Variations of Bi-Swirl Injectors with Working Conditions)

  • 서성현;안규복;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.177-180
    • /
    • 2010
  • 혼합비와 연소압에 따른 이중 와류 동축 분사기의 유량계수 변화를 살펴보았다. 연료 과농 조건에서 액체산소와 케로신을 이용하여 이중 와류 동축 분사기의 연소시험을 수행하였다. 두 종류의 분사기가 시험에 적용되었는데, 산화제 분무각 변화에 의한 추진제간 모멘텀 비 차이와 연료 노즐 직경 차이로 인한 유량계수 영향 특성이 파악되었다. 연료 와류실을 연료가 모두 채운 상태에서 연소가 이루어지는 경우 화염 구조의 변화가 없어 혼합비에 다른 유량계수 변화 또한 보이지 않는 것으로 파악하였다.

  • PDF

Electrohydrodynamic Analysis of Dielectric Guide Flow Due to Surface Charge Density Effects in Breakdown Region

  • Lee, Ho-Young;Kang, In Man;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.647-652
    • /
    • 2015
  • A fully coupled finite element analysis (FEA) technique was developed for analyzing the discharge phenomena and dielectric liquid flow while considering surface charge density effects in dielectric flow guidance. In addition, the simulated speed of surface charge propagation was compared and verified with the experimental results shown in the literature. Recently, electrohydrodynamics (EHD) techniques have been widely applied to enhance the cooling performance of electromagnetic systems by utilizing gaseous or liquid media. The main advantage of EHD techniques is the non-contact and low-noise nature of smart control using an electric field. In some cases, flow can be achieved using only a main electric field source. The driving sources in EHD flow are ionization in the breakdown region and ionic dissociation in the sub-breakdown region. Dielectric guidance can be used to enhance the speed of discharge propagation and fluidic flow along the direction of the electric field. To analyze this EHD phenomenon, in this study, the fully coupled FEA was composed of Poisson's equation for an electric field, charge continuity equations in the form of the Nernst-Planck equation for ions, and the Navier-Stokes equation for an incompressible fluidic flow. To develop a generalized numerical technique for various EHD phenomena that considers fluidic flow effects including dielectric flow guidance, we examined the surface charge accumulation on a dielectric surface and ionization, dissociation, and recombination effects.

액체질소중 교류방전 진전에 따른 방사전자파 주파수 특성 (The Frequency Characteristics of Radiated Electromagnetic Waves in accordance with AC Discharge Progress in Liquid Nitrogen)

  • 박광서;이상훈;주재현;최병주;김기채;박원주;도대호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1975-1977
    • /
    • 2000
  • In this study, a relationship between AC discharge progress and the radiated electromagnetic waves were investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum of the radiated electromagnetic waves was measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progress in nonuniform electric field depend on AC power supply. From this results, it was confirmed that when partial discharge was produced in liquid nitrogen, the signal of partial discharge was detected by frequency spectrum of the radiated electromagnetic waves. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on superconducting and cryogenic power equipments.

  • PDF

축소형 가스발생기 연소시험에서의 유량계수 특성 (Discharge Coefficient Characteristics in Hot-firing Tests of a Subscale Gas Generator)

  • 김문기;임병직;강동혁;안규복;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.73-76
    • /
    • 2011
  • 축소형 가스발생기를 제작하여 연소시험을 성공적으로 수행하였으며 분사기의 형상 변화에 따른 유량계수의 영향을 파악하였다. 연소시험 결과 연료 및 산화제 분사기의 유량계수는 혼합비와 연소압에 상관없이 거의 일정하였으며, 특히 산화제 분사기의 유량계수는 이전 결과보다 크게 향상되었다.

  • PDF

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure)

  • 박광서;신호영;최병주;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.49-55
    • /
    • 2003
  • 본 논문에서는 고온 초전도체의 냉매로서 주목받고 있는 액체질소 중에서 고체절연물 표면의 연면 방전과 트래킹 현상에 관하여 연구하였다 액체질소중 연면 방전에 많은 영향을 주는 기포 효과를 연구하기 위해 Knife형태의 전극과 평판형태의 전극을 사용하여 A-mod, B-mode, C-mode의 전극배치형태를 각각 구성하였다. 본 실험의 결과는 향후 연구되고 개발될 초전도·극저온 전력설비의 절연설계의 기초 데이터를 제공할수 있다고 판단된다.

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in $LN_{2}$ at the Atmospheric Pressure)

  • 박경태;신호영;박광서;최병주;이광식;이동인
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.114-118
    • /
    • 2002
  • This paper were investigated discharge characteristics in the Liquid Nitrogen($LN_{2}$) noticed as a cooling medium of high temperature superconductor, and the characteristics of surface discharge and tracking phenomena on the solid insulators of cryocable. In order to investigate the bubbles which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode was formed oppositely with mode A and B, C configuration. It is considered that these result are fundamental data for electric insulation design of superconductivity and cryogenic application machinery which will be studied and developed in the future.

  • PDF