• Title/Summary/Keyword: Discharge capacity test

Search Result 243, Processing Time 0.026 seconds

Concordance Rate Between the Ratings of Clinician and Self Ratings of Worker on a Functional Capacity Evaluation

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2016
  • Background: Functional capacity evaluations (FCEs) are designed to systematically assess the capacity to perform work-related tasks and to determine worker's ability to return to the previous job following work-related injuries. These evaluations may be rated either by clinician or worker. There has been a lack of consensus between the two scoring methods. Objects: This study aimed: 1) to confirm if the data are fit to the Rasch rating scale model and 2) to investigate the item-level concordance rate between the ratings of clinician and injured worker of the FCE. Methods: A cross-sectional study was conducted with a sample (n=124) of a rehabilitation program with the Occupational Rehabilitation Data Base for workers with low back pain. The functional capacity evaluation at admission and discharge was administered to clinicians and workers. The data were analyzed using both classical test theory-based Pearson's r and intra-class coefficient followed by item-level analysis with Rasch rating scale model. Results: All items of the FCE, except sitting items rated by clinician at admission and handling items rated by both clinician and worker throughout admission and discharge, were acceptable fit statistics with minor out of ranges for a misfit criterion. This may indicate that the items of the FCE overall fit to the Rasch rating scale model. Few problematic items responding differently to clinician and worker both at admission and discharge were detected with the differential item functioning analysis despite the excellent concordance rate using the two conventional statistics-sitting and handling items at admission and handling item at discharge. Conclusion: The item-level speculations using Rasch analysis of the FCE demonstrate that the ratings of clinician and self ratings of worker were psychometrically acceptable though there was an apparent discrepancy between the raters both at admission and discharge.

The effect of substitution elements(Co, Cr, Fe) on the properties of Zr-based hydrogen storage alloy electrode for Ni-MH secondary battery (Ni-MH 2차 전지용 Zr계 수소저장합금전극의 특성에 미치는 치환원소(Co, Cr, Fe)의 영향)

  • Choi, Seung-Jun;Jung, So-Yi;Seo, Chan-Yeol;Choi, Jeon;Park, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.10 no.3
    • /
    • pp.185-189
    • /
    • 1999
  • Effects of alloy modification with the $Zr_{0.6}Ti_{0.4}V_{0.4}Ni_{1.2}Mn_{0.4}$ alloy for an electrode use have been investigated. For the alloy composition, a part of Mn was substituted by Co, Cr and Fe. The experimental results showed that Co accelerated activation of alloy, and Fe and Cr improved the discharge capacity. These results agree with P-C-T curves of each alloy. But substituting Fe for Mn showed the decrease of the discharge capacity when discharged at high rate (60mA, about 1C rate). Considering both the discharge capacity and the high rate discharge property, $Zr_{0.6}Ti_{0.4}V_{0.4}Ni_{1.2}Mn_{0.3}Cr_{0.1}$ alloy was found to be the best alloy among the alloys subjected to the test.

  • PDF

Capacity Design of Lithium Ion Battery Based on the Characteristics of Materials (${\cdot}$부극 재료의 특성에 따른 리튬이온전지의 용량설계)

  • Moon Seong-In;Doh Chil-Hoon;Yun Seong-Kyu;Yum Duk-Hyung
    • 한국전기화학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.7-27
    • /
    • 1998
  • In order to design capacity of lithium ion battery, some calculations were carried out based on the characteristics of materials by the given battery shape and dimension. The principle of design was built by the interpretation of the correlation of material, electrochemical and battery factors. Parameters of materials are fundamental physical properties of constituent such as cathode. separator, anode, current collectors and electrolyte. Electrochemical factor includes potential pattern as a function of specific capacity, specific discharge capacity(or initial irreversible specific capacity or Ah efficiency) as a function of specific charge capacity and material balancing. Parameters of battery are dimension, construction hardware and performance. Battery capacity was simulated for a lithium cobalt dioxide as cathode and a hard carbon as anode to achieve 1100 mAh for the charge limit voltage of 4.2V, the weight ratio(+/-) of 2.4 and ICR18650. A fabricated test cell (ICR18650) which have weight ratio(+/-) of 2.4 discharged to 1093 mAh for the charge limit voltage of 4.2V. The sequential discharge capacity show good correspondence with designed capacity.

  • PDF

A Hydraulic Model Test for Discharge Calibration of A Parshall Flume (파샬수로의 유량검정을 위한 수리모형실험)

  • 윤용남
    • Water for future
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 1979
  • A series of hydraulic model tests have been conducted for a Parshall flume which was designed for streamflow measurements of two experimental basins in Banwol New Industrial Town. the purpose being to study the effect of urbanizations on the watershed hydrology. The model scale was determined based on the 100-year flood discharge of the basins considering the discharge cf the basins considering the discharge capacity of the hydraulic laboratory where the whole tests were conducted. The calibration equations for depth-discharge relations were derived by analyzing the model test data and were compared with those of Parshall's work. The discharge calibration for the prototype flume, which is to be constructed at the outlets of the experimental basins, was obtained through the analysis of data converted from the model test data by the laws of similarity.

  • PDF

Partial Discharge Diagnosis technology of EHV Underline Transmission XLPE cable applied FSA (FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술)

  • Shin, D.H.;Lee, Y.S.;Yang, J.S.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.153-154
    • /
    • 2006
  • We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.

  • PDF

A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology (Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

Development of ZnO Varistor for Distribution Surge Arrester (18kV, 5kA) (배전급 피뢰기(18kV, 5kA)용 ZnO 바리스터 소자 개발)

  • 박춘현;윤관준;조이곤;정세영;서형권
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.212-216
    • /
    • 2000
  • ZnO varistors for distribution surge arrester (18kV, 5kA) were developed and tested microstructure and electrical characteristics. Microstructure of ZnO varistor was consisted of ZnO grain, spinel phase and Bi-rich phase. Average grain size of ZnO varistor was $\mu\textrm{m}$ Reference voltage and lightning impulse residual voltage of ZnO varistor exhibited a good haracteristics above 5.5kV and below 11.56kV, respectively. Consequently, discharge capacity which is the most important characteristics of ZnO varistor for surge arrester exhibited excellent properties above 70kA at twice high-current impulse test. Moreover, variation rate of reference voltage and lightning impulse residual voltage showed below 5% and 2% after high-current impulse test, respectively. Leakage current and watt loss of ZnO varistor will not increase during accelerated aging test at stress condition, such as 3.213kV/$115^{\circ}C$/1000h.

  • PDF

Load Transfer on Pulsed Power Discharge Anchors (펄스방전 확공형 앵커의 하중전이에 관한 연구)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Joo, Yong-Sun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

Characteristics of MCMB Anode with VGCF As a Conducting Agent for LPB (LPB용 MCMB 부극 도전재로 VGCF를 첨가한 부극의 특성 연구)

  • Jin Bong-Soo;Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Jeong Jae-Kook;Nam Hyo-Duk;Park Hei-Gu
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.143-147
    • /
    • 2004
  • An investigation upon the characterization of MCMB anodes with different vapor grown carbon fiber (VGCF) content for application in lithium polymer battery(LPB) was carried out. When VGCF material was used as conducting agent with MCMB active material, the impedance and the initial coulombic efficiency of test cells were found to decrease with the increasing amount of VGCF. On the other hand, as a function of added VGCF the discharge capacity and the utilization linearly with increased. Impedance of test cell with MCMB anode containing $6wt\%$ VGCF exhibited the lowest value whereas the impedance of $8wt\%$ VUF contained anode was similar to that of MCMB anode without VGCF. Interestingly, $6wt\%$ VUF contained anode showed the best battery characteristics. Internal resistance and rate capacity of the cell were. respectively, $0.918{\Omega}\;at\;25C\;and\;93\%$ at 2C. Generally, rate capability and the cycleability of MCMB based test cells with $4\~6wt\%$ VGCF content exhibited better results than the other cells. In the case of $6wt\%$ VGCF containing anode, the discharge capacity of the cell faded slowly with an ultimate charge-discharge cycling capacity of 178mAh/g at the 100th cycle. Thereafter, the discharge capacity faded negligibly and the utilization of the cell at the 100th cycle was more than $90\%$. The effect of addition of VGCF is discussed in detail.

Lyophobized Ordered Mesoporous Silica Additives for Li-O2 Battery Cathode

  • Roev, Victor;Ma, Sang Bok;Lee, Dong Joon;Im, Dongmin
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.58-64
    • /
    • 2014
  • The surface of an ordered mesoporous silica (OMS) was functionalized using 1H,1H,2H,2H-perfluorooctyltrimethoxysilane at $20^{\circ}C$ and $60^{\circ}C$. It was shown that only elevated temperature allows lyophobic properties on the walls of OMS, eventually preventing pore flooding with nonaqueous electrolytes. The functionalized OMSs (OMS-F) were characterized with various techniques: wettability test, $N_2$ sorption measurement, high-resolution transmission electron microscopy (HR-TEM). Cathodes of $10mg/cm^2$ loading were prepared with a commercial Pt/C catalyst and polyvinylidene fluoride (PVDF, 2.5 wt.%) binder using a typical doctor blade method on a commercial gas diffusion layer (GDL) in the presence or in the absence of OMS-F additives. Subsequent discharge-charge curves were taken in a 1M LiTFSI-TEGDME electrolyte at 60oC in pure oxygen atmosphere. It was found that the discharge capacity was significantly affected by OMS-F: 5 wt.% of additive extended discharge capacity by a factor 1.5. On the other hand, a similar OMS material but synthesized at $20^{\circ}C$ did not show lyophobic properties and deteriorated cathode capacity.