• Title/Summary/Keyword: Discharge angle

Search Result 365, Processing Time 0.026 seconds

Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain (에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

A study on Discharge Characteristics of Rotating Discharge Hole with inlet edge shape (입구 형상에 따른 회전 송출공의 송출특성 연구)

  • Kang, Se-Won;Ha, Kyung-Pyo;Kauh, S.-Ken
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.746-752
    • /
    • 2000
  • A study on discharge characteristics of a rotating discharge hole is very important to enhance the performance of an induction motor which have external forced cooling system. The discharge characteristics of rotating discharge holes are influenced by rotating speed, length-to-diameter ratio, inlet shape of rotor holes, etc. An experimental study on the effect of chamfered inlet edge of rotor inlet part with various depth-to-diameter and inlet chamfered edge angle is conducted. Depth-to-diameter ratios range from 0 to 0.5 and inlet chamfered edge angle range from 0 to 60. As a result, there is an optimal design point of inlet chamfered edge depth. And the inlet edge angle far maximum discharge coefficient is influenced mainly by the rotating speed of discharge holes.

  • PDF

The Analysis of Hydraulic Characteristics at Channel Junctions through Hydraulic Model Tests (수리모형실험을 통한 합류부에서의 수리학적 특성분석)

  • Choi, Gye-Woon;Park, Young-Suop;Han, Man-Shin;Kim, Young-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.10
    • /
    • pp.881-888
    • /
    • 2004
  • In this study, the hydraulic characteristics at junction are studied through the variation of approaching angle, discharge in the upstream channel and the discharge ratio between the main channel and the tributary. The maximum velocity as well as the position of the maximum velocity is included in the hydraulic characteristics. The maximum velocity is increased by increasing of approaching angle, discharge in the upstream channel and the discharge ratio between the main channel and the tributary. The length from the channel junction to the point of maximum velocity is increasing by increasing of approaching angle, discharge in the upstream channel and the discharge ratio between the main channel and the tributary.

Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space (난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Numerical Analysis on the Discharge Characteristics of a Liquid Rocket Engine Injector Orifice

  • Cho, Won-Kook;Kim, Young-Mog
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • A numerical analysis was performed on the fluid flow in injector orifice of a liquid rocket engine. The present computational code was verified against the published data for turbulent flow in a pipe with a sudden expansion-contraction. Considered were the parameters for the flow analysis in an injector orifice: Reynolds number, ratio of mass flow rate of the injector orifice and inlet flow rate, and slant angle of the injector orifice. The discharge coefficient increased slightly as the Reynolds number increased. The slant angle of the injector changed critically the discharge coefficient. The discharge coefficient increased by 7% when the slant angle changed from $-30^{\circ}$ to $30^{\circ}$ The ratio of mass flow rate had relatively little impact on the discharge coefficient.

Estimation of the Water Surface Slope by the Flood Discharge with River Bend Curvature (하천 만곡률과 홍수량에 따른 수면경사도 산정)

  • Choi, Han-Kyu;Lee, Mun-Hee;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.129-137
    • /
    • 2006
  • In this research, we made a one and two-dimensional analysis of numerical data collected from the bend curvature of a bended river section. According to the result from the numerical analysis, the inflow & output angle caused a water level deviation which increased with an increase of the flood discharge. From the water level deviation of our two-dimensional numerical model, we obtained the maximum slope of 6,67% when the inflow and output angle was 105 degrees and the flood discharge was 500 CMS. As for the right side, the differences with the one-dimensional numerical model were reduced when the angle was more than $90^{\circ}$. As for the left side the differences were reduced when the angle was more than $105^{\circ}$. For a river with more than 90 degrees bend curvature, a hydraulic experiment would be more appropriate than a numerical analysis.

  • PDF

The Change of Flow depending upon the Discharge and Approaching Angle at Channel Junctions (합류부의 유량 및 접근각도에 따른 흐름변화)

  • Choi, Gye-Woon;Park, Young-Suop;Han, Man-Shin
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.623-630
    • /
    • 2004
  • In this paper, the hydraulic model tests are conducted for the hydraulic characteristics at channel junctions. The experiments are examined through the variation of approaching angle, discharge in the upstream main channel and the discharge ratio between the main channel and the tributary. The experiments are conducted in the channel model having the length of 450cm, the widths of 40cm and 32cm. Four water tanks and pumps are installed in the experimental channel. The length of stagnation zone is increased by Increasing of approaching angle and the discharge in the upstream channel. The length of stagnation increase with the discharge ratio between the main channel and the tributary. However, the variation of the stagnation zone near the channel junctions is little at the same approaching angles and the discharge ratioes between the main channel and tributary. However, the variation of the stagnation zone near the channel junctions is little at the same approaching angles and the discharge ratioes between the main channel and tributary. Accelerating zone of the velocity is occurred in the middle of the channel in the small approaching angle. However, the influence zone of the accelerating velocity is increased by increasing the approaching angle.

Hydraulic Performance of Francis Turbine with Various Discharge Angles (유출각 변화에 따른 프란시스 수차 성능해석)

  • Jeon, J.H.;Byeon, S.S.;Choi, Y.C.;Park, J.S.;Kim, Y.J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.10-14
    • /
    • 2013
  • In this study, we have numerically investigated the hydraulic efficiency with various values of discharge angle($11^{\circ}$, $12^{\circ}$, $14^{\circ}$, $15^{\circ}$, $17^{\circ}$, $18^{\circ}$, $20^{\circ}$) in the Francis turbine of hydropower generation under 15MW with fixed values of head range of 151m and flow rate($10.97m^3/s$). We also conducted the numerical analysis with constant inlet angle in the Francis turbine using the commercial code, ANSYS CFX. Hydraulic characteristics for different values of the runner blade angle are investigated. The results showed that the change of discharge angles significantly influenced on the performance of the turbine hydraulic efficiency.

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

An Analysis on the Characteristics of Separation Zone Due to a Bed Discordance at Confluence (합류부 하상고 불일치에 의한 분리구역 특성분석)

  • Choi, Heung Sik;Mo, Sun Jea
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.625-634
    • /
    • 2015
  • The diverse patterns of separation zone according to the marked bed discordance by dredging at confluence in addition to the confluence angle of tributary and discharge ratio between tributary and main channels have been analyzed by CCHE2D model simulation. The separation zone is defined by inside of zero velocity boundary at down-stream of confluence. The separation zone dose not formed at the $30^{\circ}$ of confluence angle of tributary. The size of separation zone increases as the discharge ratio and confluence angle increase in general. The separation zone decreases as the dredging depth increases which shows the relative momentum reduction compared by the flow volume increasing by dredging at confluence. The contraction factor with the variation of confluence angle and discharge ratio has been investigated and confirmed the corresponding conveyance decreasing results in backwater effect. The regression equation of shape factor with confluence angle and discharge and dredging depth ratios has been suggested.