• 제목/요약/키워드: Discharge Tube

검색결과 335건 처리시간 0.019초

분진운의 최소점화에너지에 대한 정전기 방전회로의 매개변수 영향 (Influence of Electrostatic Discharge Circuit Parameters on the Minimum Ignition Energy of Suspended Dust Clouds)

  • 문균태;정재희;미주키 야마구마;최광석
    • 한국안전학회지
    • /
    • 제25권5호
    • /
    • pp.22-26
    • /
    • 2010
  • The ignitability(minimum ignition energy, MIE) of a suspended dust clouds is very important aspect of technical safety indices. This paper reported the experimental results dealing with the influence of discharge circuit on the MIE of a suspended dust clouds. The movement of a suspended dust clouds was also observed with the high speed camera. The Hartmann vertical-tube apparatus(MIKE-3) described in the international standard of IEC and Polypropylene (PP, 50% volume-average, D50: $761{\mu}m$) resin powders were used in this experiment. The following results were obtained: (1) the MIE of a suspended PP powder depended markedly on the discharge circuit; in other words, when a resistor was connected in series with the discharge sparking circuit(RC), the lowest value(31mJ) of MIE was obtained for a suspended PP powder comparison with the other circuits(C circuit; 370mJ or LC circuit; 71mJ). (2) the discharge duration time is more important than other factors with regard to MIE of a suspended PP powder.

Al2O3 유전체를 이용한 산소/공기 원료에 따른 오존발생기의 특성 (A Characteristic Analysis of Ozone Generator Using the Al2O3 Ceramic Dielectric According to Gas Type(O2/Air))

  • 박현미;송현직;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.76-81
    • /
    • 2014
  • The ozone generation is commonly made with silent discharge method using quartz glass dielectric. In this paper, using $Al_2O_3$ dielectric to instead of the traditional quartz glass dielectric to improve the system efficiency is presented. The dielectric was manufactured as tube shape (Internal diameter${\times}$ Outside diameter: $11{\times}15mm$) using 99% $Al_2O_3$ ceramic. The characteristics of dielectric discharge and ozone generation were studied of experiments with variation of discharge power, discharge electrode space and rate of flow for supplied gas ($O_2$/Air). As the experimental results, in the same discharge space, the ozone concentration continuously increased with input power increasing, and ozone yield increased until saturation happened. Also, the expended power increased with discharge space extended due to discharge power increased. In additional, the ozone concentration of oxygen ozone was higher than air that was observed when using oxygen ozone in proposed experiments.

구동 온도와 방전관 길이에 따른 ICP 광원의 전기.광학적 특성 (Electro-Optical Characteristics of an ICP Light Source Depending on Driving Temperature and Length of Discharge Tube)

  • 임연찬;박대희
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.107-113
    • /
    • 2008
  • 본 실험은 구동 온도와 방전관의 길이에 따라 변화하는 ICP 광원의 전기 광학적 특성에 대해서 알아보았다. 광원의 전기 광학적 특성이 정상상태에 놓이는 구동 조건을 확인하기 위하여 시간에 따른 전력 소모와 광속의 변화를 측정하였다. 전력소모와 광속의 시간에 따른 변화를 측정한 결과를 통해서 볼 때 최초구동에서 70분이 경과한 이후부터 전력소모는 초기값에 대해 1.45[%], 광속은 0.36[%]의 안정성을 나타냈다. 항온챔버 내에서 온도를 5구간으로 나뉘어 변화하면서 구동 온도에 따른 ICP 광원의 광학적 특성을 알아보았다. 휘도는 온도의 상승과 비례적으로 증가하였으나 $46.7[^{\circ}C]$ 이상에서는 오히려 감소하는 결과를 얻을 수 있었다. 파센법칙과 함께 보일-샤를의 법칙을 통해 0.02[Torr]의 압력이 변화함에 따라 더 높은 방전전압이 요구되지만 충분한 전압이 안정기에서 공급되지 못하기 때문이라 판단된다. 이와 더불어 방전관 길이에 따라 광원에 인가되는 전력과 전류을 측정하였다.

Experimental Investigations on Upper Part Load Vortex Rope Pressure Fluctuations in Francis Turbine Draft Tube

  • Nicolet, Christophe;Zobeiri, Amirreza;Maruzewski, Pierre;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.179-190
    • /
    • 2011
  • The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The influence of outlet bubble cavitation and air injection is also investigated for low cavitation number. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

오존 발생기용 공진형 인버터의 출력특성 (The output characteristics of resonant type inverter for ozone generator)

  • 강욱중;이현우;서기영;권순걸;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for Ozone Generator are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석 (Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes)

  • 이민아;류민영;신동진;김태균
    • 소성∙가공
    • /
    • 제24권2호
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.

플라즈마 살균용 전원장치에 관한 연구 (A study on power system for plasma sterilization)

  • 강욱중;김영문;문상필;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템 (Resonance inverter power system for plasma sterilization effective improvement)

  • 김주용;문상필;김종실;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF