• 제목/요약/키워드: Discharge Test

검색결과 1,592건 처리시간 0.033초

FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술 (Partial Discharge Diagnosis technology of EHV Underline Transmission XLPE cable applied FSA)

  • 신동훈;이용성;양종석;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.153-154
    • /
    • 2006
  • We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.

  • PDF

정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구 (A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

화상처리를 이용한 방전와이어의 성능평가에 대한 연구 (A Study on the efficiency test of Electric Discharge Machine Wire using Image processing)

  • 배진한;이위로;유송민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.117-122
    • /
    • 2002
  • Electrical discharge machining uses thermal energy from electrical discharge, while wire electrical discharge machining (WEDM) technology is widely used in conductive material machining. This paper proposes a method for evaluating the characteristics of wires in WEDM. In order to evaluate the wire processing performance, processing speed and roughness, straightness, corner processing have been assessed with precision experiment equipment and image processing including Laplacian filtering with various threshold levels.

  • PDF

쇄석Mat를 이용한 수평배수공법 설계사례 (Design Example of Gravel Mat for Horizontal Drains)

  • 정경한;이영근;이시우;김재성;김병탁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.174-187
    • /
    • 2005
  • Recently, because of environment, cost, supply and demand factors, though applying sea-sand as horizontal drains is getting difficult that usage of Gravel has been growing in large size of construction sites, Study on engineering properties and behavior characteristics of Gravel stratum is not thoroughgoing enough. We have applied Gravel Mat as the horizontal drains in O O construction site. We also conducted several field tests such as Material property test, Geosynthetics damage test with Repeated load, Discharge capacity test performed by inflow of upper soil and In-situ PBD Penetration test to review the application of Gravel Mat. Test results show that Gravel Mat is not only advantageous in Trafficability and Water drainage by Consolidation due to its great Internal friction angle and Permeability, but also easy to penetrate with Mandrel and has great discharge capacity and guarantee of the stability against geosynthetics damage at the same time. With these benefits Gravel Mat shows great application in fields.

  • PDF

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험 (Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator)

  • 윤수환;김태규
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.527-528
    • /
    • 2012
  • 플라즈마 유동제어를 통한 공기저항저감을 위해 DBD(Dielectric Barrier Discharge) 플라즈마 구동기를 설계하였고, 2D 시험모델의 풍동시험을 통해 항력저감을 측정하였다. 풍속이 없는 경우에는 유동박리 및 표면마찰저항이 존재하지 않으므로 플라즈마 유동제어를 통한 항력저감도 없었다. 2m/s의 풍속에서 유동박리제어를 통해 항력이 9.7%까지 감소됨을 확인하였으며, 풍속이 증가할수록 항력저감은 감소하였다.

  • PDF

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Metallic Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.127-132
    • /
    • 1999
  • Both motion of free metallic particles from which most GIS internal failures are caused and partial discharges from the particles were examined using EHV GIS test chamber. Effects from particle length and gas pressure which are main factors to lead to breakdown failure were investigated theoretically and experimentally. Magnitude of both lift-off voltage and partial discharge inception voltage were measured respectively and, through these measurements, this paper showed the possibility of predicting breakdown fault and of taking action to prevent the fault in advance. The measurement of partial discharge when the particles began to move could be adopted to decide minimum sensitivity in developing predictive diagnostic equipments. Both the amount of apparent discharge and real discharge in GIS were examined theoretically and experimentally, then experimental results were analyzed on the basis of the theory.

  • PDF

영전압 방전 기능을 갖는 새로운 배터리 충방전시스템 (A Novel Battery Charge/Discharge System with Zero Voltage Discharge Function)

  • 응웬쾅만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.169-170
    • /
    • 2013
  • One important test for formation and grading of the lithium-ion battery is to confirm the performance of the battery while discharging battery down to zero volts. In this paper, a novel charge/discharge converter with zero-voltage discharge function is proposed. The proposed converter is able to discharge the battery until the voltage reaches to zero volts. The phase-shifted full bridge method is used to charge the battery and the current-fed push-pull method with bidirectional switches is used for the discharge. The ZVS turn-on is achieved in the charge operation and the ZVS turn-off in the discharge operation. The performance of the system is verified by the experiments using lithium-ion batteries.

  • PDF

변압기 부분방전에 의한 초음파 신호의 발생형태 (Patterns of the Ultrasonic Signal caused by Partial Discharge in Transformer)

  • 권동진;최인혁;정길조;박찬영;나현석;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2000
  • Generally, it is known that many partial discharges are occurred in one voltage cycle. In this case, it is not easy to distinguish between ultrasonic signals caused by the partial discharge. We describes a pattern of the ultrasonic signal by the partial discharge in transformer. The test setup for ultrasonic signal measurement was to simulate a internal partial discharge by using a needle to plane electrodes. We compared the number of partial discharge and ultrasonic signal in one voltage cycle. The results showed that it was possible to distinguish between ultrasonic signals by analysing partial discharge detection method and ultrasonic signal on time domain.

  • PDF