• 제목/요약/키워드: Discharge Test

검색결과 1,600건 처리시간 0.026초

The discharge characteristic of Li ion doped MgO film in a flat fluorescent lamp structure

  • Ryu, Si-Hong;Lee, Seong-Eui;Ahn, Sung-Il;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1388-1390
    • /
    • 2007
  • This paper investigates how various concentrations of lithium ion influence on crystallization of MgO in thin films formed by spin coating and an the discharge characteristic in a flat fluorescent lamp structure. The XRD results indicate $Li^+$ ion enhances the growth of MgO crystal in a spin coated thin film. The discharge property with the $Li^+$ ion doped MgO films show the lithium ion in MgO film clearly reduce the initial discharge voltages of test devices. Interestingly, the test panels with various doped MgO film have somewhat higher static memory margin of than that of pure-MgO owing probably to the pore structure of spin coated MgO films. The CL spectra, which confirm that the doping creates defects energy levels in the band gap of MgO, show the $F^+$ center is the main defects in doped MgO films.

  • PDF

국내 PBD재의 배수성능과 진공효과에 의한 통수능력 향상에 관한 연구 (A Study on Drainage Performance of Domestic Plastic Board Drains and Recovery of Discharge Capacity by Vacuum Effect)

  • 박영목
    • 한국지반공학회지:지반
    • /
    • 제13권2호
    • /
    • pp.39-54
    • /
    • 1997
  • 연약지반 개량공법으로 국내에서 생산된 플라스틱 보드 드레인(PBD)이 많이 사용되고 있으나 이들에 대한 물리적 성질 및 배수성능의 검증이 미약한 실정이다. 또한 PBD의 웰 레지스턴스(well resistance)에 크게 영향을 미치는 공기(기포)의 영향에 대한 인식이 부족하다고 판단된다. 따라서 본 연구에서는 대형 실험장치를 이용하여 먼저 국산 PBD를 중심으로 물리적 성질 및 배수성능 시험을 실시하여 제품의 질적 수준을 규명하고 대표적인 국외제품과 비교했다. 아울러 PBD재의 꺾임 부분에 누적된 공기(기포)가 통수능력에 지장을 초래하는 것을 재확인하였으며 현장에서 적용할 수 있는 진공펌프를 이용하여 필기(기포)를 제거시키므로써 통수능력의 회복이 가능하다는 것을 나타냈다.

  • PDF

Carbon Nano-Powder Functionalization and Disperisibility with Plasma Discharge

  • 강유석;정만기;이덕연;송석균;김성인
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.491-491
    • /
    • 2013
  • A novel plasma system has been developed for 3-dimensional modification of the carbon nano-powders. Improvement of dispersion of these nano materials are studied by plasma discharge, not using chemical modification. The plasma process is considered to great advantages over wet chemical process due to environmental, economic viewpoint, and uniformity over the treated volume. The uniform dispersion is a critical factor for these material's nano composite applications. Using this plasma system, graphene, carbon black, and CNT was treated and functionalized. Several key discharge conditions such as Ar/H2/O2 or Ar/H2/NH3 gas ratio, treatment time, power, feeder's vibration frequency are investigated. Hydrophobic of graphene has turned some more into hydrophilic by reaction test with water, electrophoresis, surface contact angle test, and turbidity analysis. The oxygen content ratio in the plasma treated CNT has increased about 3.7 times than the untreatedone. In the case of graphene and carbon black, the oxygen- and nitrogen- content has been enhanced average 10%. O-H (N-H) peak, C-O (C-N) peak, and C=O (C=N) peak data have been detected by FTIR measurement and intensified compared to before-plasma treatment due to O2 or NH3 content.

  • PDF

UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (PD measuring on MV XLPE Calble by Using UWB Antenna)

  • 양상현;임광진;이용성;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

개별화된 교육이 허혈성 뇌졸중 환자의 불안과 자가간호수행에 미치는 효과 (The Effects of Individualized Education on Stroke Patients' Post-discharge Anxiety and Self-care Compliance)

  • 박형숙;이미헌;하재현
    • 재활간호학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: This study aimed to identify the effect of individualized education on stroke patients' post-discharge anxiety and self-care compliance. Methods: It was a pretest-posttest design with non-equivalent groups. A total of 32 hospitalized stroke patients in experimental group were given individualized education three times at one day before, the day of and one week after discharge. Data were analyzed using descriptive statistics, t-test and $x^2$-test. Results: The scores of anxiety at posttest were $45.66{\pm}9.58$ in control group and $35.44{\pm}8.21$ in the experimental group. Self-compliance scores were $44.00{\pm}7.99$ in control and $61.06{\pm}7.69$ in the experimental group. These indicate that anxiety score is significantly lower (t=-4.58, p<.001), and self-compliance score is significantly higher (t=8.70, p<.001) in experimental group. Conclusion: If stroke patients receive a relevant individualized education, it could help reduce their anxiety. Also it would be useful to maintain and improve their self-care compliance after discharge.

초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극 응용 (Application of AI-foil Electrode for Detecting Partial Discharge in Middle Joint Box)

  • 김대열;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.79-81
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

내관(P6) 지압이 항암화학요법을 받는 폐암 환자의 오심과 구토, 식욕부진에 미치는 영향 (Effects of Nei-Guan Acupressure on Chemotherapy-related Nausea, Vomiting, and Anorexia in Patients with Lung Cancer)

  • 성연실;조의영;이영숙;양혜림;이화정
    • 동서간호학연구지
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: This study tested the effects of Nei-Guan acupressure on nausea, vomiting, and anorexia of lung cancer patients on chemotherapy. Methods: A nonequivalent control group pre-post test design was used to identify the effect of Nei-Guan acupressure on nausea, vomiting, and anorexia of lung cancer patients on chemotherapy. The participants were 60 patients who were admitted to a hospital for chemotherapy from February 1 to October 28, 2009. The patients were randomly assigned to the control group (n=30) or experimental group (n=30). The data were analyzed using Mann-Whitney test. Results: Nausea, vomiting, and anorexia were significantly decreased in the experiment group compared to the control group on the day of discharge from the hospital. However, the levels of nausea, vomiting, and anorexia between two groups were not statistically significant seven days after the discharge. Conclusions: Nei-Guan acupressure is effective in decreasing nausea, vomiting and anorexia of the patients with lung cancer on chemotherapy on the on the day of the discharge while the effectiveness is not certain 7 days after the discharge. Further study is needed to confirm these findings.

펄스 방전 기술에 의한 지반 확공 현상 수치해석 모사 (Numerical Simulation of Ground Expansion Induced by Pulse Discharge Technology)

  • 박현구;이승래;김선주;조규연
    • 한국지반공학회논문집
    • /
    • 제26권3호
    • /
    • pp.25-34
    • /
    • 2010
  • 본 연구에서는 펄스 방전 기술의 적용에 따른 지반 확공 현상에 대한 수치해석적인 연구를 수행하였다. 실내 펄스 방전 시험을 통하여 충격파 발생을 측정하였으며 수중 폭발 모델을 바탕으로한 유제-구조물 유한요소해석을 통해 실내 시험에서 계측된 충격파를 모사하였다. 이를 바탕으로, SPT N값으로부터 경험적으로 얻어지는 지반 물성이 적용된 점성토 지반에 대한 확공 해석을 수행하였으며 현장 시험과 유사한 예측 결과를 얻을 수 있었다.

구형 ZrO$_2$를 충진한 방전관의 수질 변환 및 대장균제거 특성 (Property Conversion of Water and Removing Characteristics of Escherichia Coli Inner Discharge Tube With ZrO$_2$Beads)

  • 이동훈;박재윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.143-148
    • /
    • 2004
  • This paper shows property conversion of water and removing characteristics of Escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of Escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of Escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$beads is increased, the removal ratio of Escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$beads is increased, the removal time of Escherichia coli is to be decreased because dielectric polalization of $ZrO_2$beads. Also, the removal ratio of Escherichia coli of the discharge tube with $ZrO_2$beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$beads. And a satulation punt of ozone and $H_2$ $O_2$generation density inner water was appeared near 60[min].

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.