• Title/Summary/Keyword: Discharge Site

Search Result 460, Processing Time 0.032 seconds

Partial Discharge Monitoring for $SF_6$ Insulated MV Switchgear using UHF sensors (UHF Sensor를 이용한 SF6 절연 MV 개폐기의 부분방전 검출 시스템)

  • Lee, Do-Hoon;Kang, Won-Jong;Shin, Yang-Sop;Kim, Young-Geun;Oh, Il-Sung;Kim, Dong-Myung;Kwon, Tae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2040-2041
    • /
    • 2007
  • In this paper, the UHF PD(Partial Discharge) sensors for $SF_6$ insulated MV $SF_6$ switchgear have been proposed and related investigations have been performed in order to detect the PD which were produced inside the MV $SF_6$ switchgear. Firstly, the internal type UHF PD sensor based on spiral antenna theory has been developed. This type sensor is highly sensitive and has lowly effect on by on-site noise. Secondly, the external type UHF PD sensor was developed based on log periodic antenna concept. This type sensor is removable and detectable for operating switchgear. These sensors were designed and simulated using RF simulation tool. In order to verify the sensitivity of these sensors, we performed the on-site test using the mock-up switchgears including the artificial defects which were the protrusion on high voltage conductor, free moving metal particle and surface defect on insulator. These mock-up switchgear were installed on the test distribution line.

  • PDF

A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System (온라인 및 오프라인 PD 모니터링에 관한 연구 동향)

  • Choo, Jong-Hoon;Hong, Chang-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF

The Evaluation of Water Quality in Coastal Sea of Saemangeum by Chemical Environmental factors (새만금 하구역의 이화학적 환경요인에 따른 수질 평가)

  • Kim, Jae-Ok;Kim, Won-Jang;Jo, Kuk-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.57-65
    • /
    • 2007
  • The objective of this study was to evaluate chemical water quality by hourly monitoring(25hr) of Saemangeum esturary. For this study, we selected 2 sites like a Mangyong Bridge(St. 6) and Dongjin Bridge(St. 7). Inflow of salt water was not detected during low tide(maximum 553, 508cm) of all stations, while the salinity rises were detected in spring tide(750cm). When 602m of maximum tide was reached, salinity concentration was increased at St. 7, while there was no change in St. 6. Therefore, We know that salinity variation is greatly influenced by tide height at survey site. Also, significant variance of salinity(p<0.05) was found between St. 6 and St. 7 because dike construction made the flood tide move into the Dongjin river. Total suspened solids(TSS) concentration was increased because of the river runoff at St. 6, and also the turbulance and resuspension according to salt intrusion at St. 7. During the high tide, the water discharge from the sea seemed to dilute the nutrient but to elevate TSS concentration in St. 7. Silicate and nitrate concentrations in the studied site were decreased by the mixing of sea water, whereas the evident trend of phosphate concentration was not found. This result can be explained by the phosphorus condition. Phosphorus exists inactive when it is affected by hydrated iron and adsorbed onto suspended matters. Compared to the environmental conditions of the St. 6 and St. 7, physical factors such as temperature, dissolved oxygen and TSS have statistically no significant difference(p<0.001), but nutrient concentrations were higher at St. 6 than St. 7. It could be suggested from these results that it is important to control the discharge of fresh water by sewage treatment plants located in St. 6 for water quality management.

The Effectiveness of Korean Medical Rehabilitation Treatment after Musculoskeletal Surgery: A Retrospective Observational Study (근골격계 수술 후 한방재활치료의 효과: 후향적 관찰연구)

  • Woo, Hyeon-Jun;Geum, Ji-Hye;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.3
    • /
    • pp.151-162
    • /
    • 2020
  • Objectives This study aimed to evaluate the effectiveness of postoperative Korean rehabilitation treatment for patients with musculoskeletal disorders. Methods The medical records of patients undergoing Korean medical rehabilitation after a musculoskeletal surgery, from January 1, 2016, to December 31, 2019, were analyzed retrospectively. The effect of treatment was evaluated by using a numeric rating scale (NRS) and questionnaire for each surgical site. When the same patient was re-admitted after discharge, it was treated as the same case if it was within 7 days from the discharge date; otherwise, it was treated separately. If the period of hospitalization was within 7 days or the chief complaint was not related to musculoskeletal surgeries, the case was excluded. Results In total, 480 cases were included in this study. Acupuncture (99.8%), moxibustion (95.6%), cupping (97.5%), Chuna manual therapy (81.5%), Korean medical physiotherapy (61.0%), Daoyin exercise therapy (26.3%), and herbal medicine (87.7%) were used as the Korean medical rehabilitation treatments. A significant improvement was noted when comparing the NRS and questionnaire results for each surgical site at the time of admission and discharge. Conclusions Korean medical rehabilitation can be effectively used for patients who have undergone musculoskeletal surgeries, to relieve pain and enable returning to daily activities. However, further research with a high level of evidence is necessary to support this finding.

Characteristics of Pollutants Discharge from Hoengseong Watershed during the Dry and Rainy Seasons (횡성호 유역의 비강우시 및 강우시 오염물질 유출특성)

  • Roh, Sung-Duk;Kim, Jang-Hyun;Lee, Dae-Keun;Kim, Seon-Joo;Sohn, Byeong-Yong;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.695-705
    • /
    • 2006
  • This study was carried out to make a basic information for establishment of countermeasures against water pollution of Hoengseong watershed, accordingly we investigated the characteristics of pollutants discharge and estimated the unit loads from Hoengseong watershed. Seven sites (S1~S7) were selected for sampling and samples were taken 4 times during the dry and rainy seasons, respectively. During rainfall events, measured site mean concentration (SMC) ranges of $BOD_5$, $COD_{Mn}$, TOC, SS, Turbidity, T-N and T-P were 0.8~1.3 mg/L, 2.3~6.3 mg/L, 1.284~2.110 mg/L, 3.4~69.3 mg/L, 2.36~52.68 NTU, 1.243~1.669 mg/L and 0.025~0.070 mg/L, respectively. And the calculated annual unit loads of $BOD_{5}$, $COD_{Mn}$, SS, T-N and T-P in Hoengseong watershed were 1.327 kg/ha/yr, 7.349 kg/ha/yr, 87.075 kg/ha/yr, 1.848 kg/ha/yr and 0.103 kg/ha/yr, respectively. It was difficult to directly compare the unit loads proposed in this study with the estimated existing those. Because the unit loads in this paper were estimated not by land use types, but by complex land use of non-urban area. From the survey results, they showed that the unit loads in Hoengseong watershed were similar to those exisiting in the forest area, and showed lower than those existing in the paddy/dry field.

Has the Restoration Project of Pseudopungtungia tenuicorpa (Pisces: Cyprinidae) in the Jojongcheon Stream, Hangang River Failed? (조종천에 재도입된 멸종위기어류 가는돌고기 Pseudopungtungia tenuicorpa (Pisces: Cyprinidae) 복원사업은 정말 실패하였는가?)

  • Han, Mee-Sook;Choi, Kwang-Seek;Ko, Myeong-Hun
    • Korean Journal of Ichthyology
    • /
    • v.32 no.3
    • /
    • pp.182-190
    • /
    • 2020
  • The endangered Pseudopungtungia tenuicorpa were reintroduced to the Jojongcheon Stream in the Hangang River 2011~2012 as part of the restoration project. Since then, the restoration project has been evaluated as a failure because the P. tenuicorpa were not collected from the discharge site 2014~2016. This study was conducted 2017~2019 to verify that the P. tenuicorpa restoration project failed. Six locations were selected, including the discharge site, and the fish collection method used skimming nets, cast nets, long bag set nets, and scuba diving. In the survey results, 13 individuals were collected in a 0.5 km section, including the discharge station. The P. tenuicorpa habitat was approximately at a water depth of 0.5 m to 2 m in run water flow with the boulders and rocks. The age of the collected P. tenuicorpa were 0+ to 3-years-old, and the generation alternation was occurring stably. Thus, the P. tenuicorpa restoration project was evaluated as partially-successful, as the P. tenuicorpa, re-introduced to the Jojongcheon Stream, settled in its habitat with stable generation alternation.

Point Frequency Analysis for Determining the Design Flood at Indogyo Site (한강 인도교 지점의 계획홍수량 산정을 위한 지점빈도해석)

  • Yun, Yong-Nam;Won, Seok-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.4
    • /
    • pp.469-481
    • /
    • 1998
  • A point frequency analysis is carried out for the Indogyo site at the Han river using 68 annual maximun flood data for the period of 1918-1992. Computed frequency discharges using the three parameter log-normal, type-I extreme value, type-III extreme value, and Pearson type-III computed as 35,500 m3/sec and 39,000 m3/sec, respectively, 33,500 m3/sec and 37,500 m3/sec of corresponding return periods are computed when the flood control effect of the dams are taken into account. The resulting flood discharge of 37,500 m3/sec is similar to the current design flood of 37,000 m3/sec in downstream reach of Han river, so, it could be desirable to keep the the current design flood, considering the increasing tendency of the flood due to the climate change. Keywords : frequency analysis, flood discharge, Han river.

  • PDF

An Experimental Study on the Extinguishing Performance of Sprinkler Heads according to Discharge Coefficient (스프링클러 헤드의 방수상수에 따른 소화성능에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.32-38
    • /
    • 2018
  • The sprinkler system is a basic fire extinguishing system widely used, but there is a lack of quantitative assessment of its performance. In this study, to evaluate the fire extinguishing performance of the sprinkler head according to the discharge coefficients, experiments were conducted. Experimental sprinkler heads were selected with heads having K50, K80 and K115 water discharge coefficients, and the fire source was assumed to be an indoor fire in Class A Model 1. As experimental results, the time required for the fire chamber to cool down to $200^{\circ}C$ was 26 seconds for the K115 head, 414 seconds for the K80 head, and 481 seconds for the K50 head, so the cooling time of the K115 head was decreased by 94.5% compared to K50 head. In the case of restoring the oxygen concentration to 15%, the K115 head did not decrease below the oxygen concentration of 15%, and the K80 head took 145 seconds and the K50 head took 484 seconds. The lowest oxygen concentration in the fire chamber was 16.1% for the K115 head, 14.33% for the K80 head, and 11.28% for the K50 head, indicating that the K115 head was superior to the K80 and K50 heads by 13.1% and 43.7%, respectively. As the experimental results show, there is big difference in the extinguishing performance depending on the discharge coefficients of the sprinkler head. Therefore, in designing the sprinkler system, the discharge coefficients of the sprinkler head should be selected considering the heat release rate at the installation site and the fire extinguishing characteristics of sprinkler head.

A Numerical Flood Routing Model at the Downstream of the Han River (한강하류부(漢江下流部)의 홍수추적(洪水追跡) 수치모형개발(數値模型開發))

  • Lee, Won Hwan;Park, Sang Deog
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.63-70
    • /
    • 1989
  • The numerical model for the flood routing at the downstream of the Han river is established by using Preissmann's four-point linear implicit finite difference scheme. It is approved by the applications of this model to the selected four flood events that the released discharge hydrograph at Paldang dam which is used as upstream boundary condition of this model is better than the discharge hydrograph at Goan site. Such a result is due to the poor reliability of rating curve at Goan site. As its alternative, new rating curve at Goan site is proposed by means of applications of this numerical flood routing model. The variations of Manning's roughness coefficient may be negligible in view of the flood routing results.

  • PDF

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF