• 제목/요약/키워드: Discharge Rate

검색결과 2,267건 처리시간 0.026초

하수처리수 방류 하천의 물환경과 저서성 대형무척추동물 군집 생태 연구 (A Study on Water Environment and Benthic Macroinvertebrate Community in Reclaimed Wastewater Effluent Dominated Stream)

  • 손정원;곽진숙;조갑제;류동춘
    • 한국물환경학회지
    • /
    • 제37권3호
    • /
    • pp.190-203
    • /
    • 2021
  • Water quality, benthic macroinvertebrate communities, and other factors were investigated to explore the effects of the effluent discharge from a sewage treatment plant into Jwagwang stream in Busan in 2019. During the study period, the flow rate of this stream was in the range of 10,400 m3/day to 52,200 m3/day except for the discharge of about 24,000 m3/day of the effluent. After discharge, the flow velocity increased by about 65% and the water depth increased by about 40%. At sites downstream of the discharge point, BOD, COD, TOC, T-N, T-P, and other water quality values were worse than those of the upstream sites. The periphytic algal chlorophyll-a concentrations in the natural substrata were higher than those of the upstream sites, especially in May and August. However, at sites downstream of the discharge point, the individual numbers of Annelida were decreased and individual numbers of the insecta of arthropoda were increased. Also, species numbers and the diversity and dominance indexes were improved in the sites downstream of the discharge point. The functional feeding groups (FFGs) of collector-filterers were increased and the habitat orientation groups (HOGs) of sprawlers, burrowers, and clingers were especially increased at the sites with additional reclaimed wastewater effluent flow. Regardless of the effluent discharge, BMI, an indicator of ecological stream health using benthic macroinvertebrate species, did not show large gaps between the study points. Although the water quality of the sites downstream of the discharge point was much worse than those upstream, their ecosystem soundness was better than those of the upstream sites from an ecological perspective.

남강댐 담수 방류시 진주만을 빠져나가는 입자들의 수로별 분배율 평가 (Distribution Rate of Particles Exiting Jinju Bay in the Namgang Dam Freshwater Discharge)

  • 노남윤;권민선;권혜련;김종구
    • 해양환경안전학회지
    • /
    • 제29권6호
    • /
    • pp.576-586
    • /
    • 2023
  • 남강댐 하류역에 위치한 사천만, 진주만, 강진만에서 가화천 방류에 따른 담수 배제의 분배 특성을 평가하기 위하여 입자추적 수치실험을 실험하였다. 가화천을 통해 3개의 방류조건(무방류, 강우시 방류, 홍수시 방류)에서 입자 1000개를 투여하여 노량수도, 대방수도, 창선해협으로 빠져나가는 입자의 수를 비교하였다. 가화천을 통한 방류량이 늘어날수록 노량수도로의 입자 분배율이 증가하고, 대방수도로의 분배율이 감소하는 것을 확인할 수 있었다. 즉, 평소에는 가화천 하류에 위치한 물질의 약 95%가 대방수도를 통해 빠져나가다가, 강우에 의해 남강댐의 방류량이 증가하면서 노량수도로의 분배율이 증가하며, 홍수시에는 노량수도로의 입자 분배율이 45.5% 까지 증가하는 것을 확인할 수 있었다.

델파이기법을 이용한 급성심근경색증 질 평가지표 가중치 부여 (Weighting of Acute Myocardial Infarction Quality Indicators using Delphi Method)

  • 김형선;조연희
    • 한국보건간호학회지
    • /
    • 제28권3호
    • /
    • pp.565-573
    • /
    • 2014
  • Purpose: Health Insurance Review & Assessment Service (HIRA) launched an Acute Myocardial Infarction(AMI) assessment for the Payment For Performance(Quality Incentives) Pilot Project from July 2007. Assessment measures of AMI were composed of five process measures and one outcome measure, and each measure was incorporated into one composite quality score to Pay for Performance. Method: For calculation of composite quality score, we considered weighting for the measures using the Delphi method. The questionnaire was composed of three measure groups, 'Reperfusion rate'(Fibrolytic therapy received within 60 minutes of hospital arrival, Primary Percutaneous Coronary Intervention within 120 minutes of hospital arrival), 'Medication prescription rate'(Aspirin at arrival, Aspirin prescribed at discharge, Beta-blocker prescribed at discharge) and 'Survival Index'(30-day mortality rate). Result: A panel composed of 18 and completed a questionnaire by allocation of 10 scores to the three above mentioned measure groups. The Delphi was carried out until three rounds of surveys. In conclusion, each measure group was weighted differently and the 10 scores were allocated as 4.5 to 'Reperfusion rate', 2.5 to 'Medication prescription rate', and 3.0 to 'Survival Index'. Conclusion: The results of this study proposed the calculation method for weighting of Acute Myocardial Infarction quality indicators.

2단 유량제어 Fluidic Device의 특성에 관한 연구 (A Study on the Characteristics of Two-Step-Flow-Control Fluidic Device)

  • 조봉현;배윤영;박종균;유성연
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.53-61
    • /
    • 2001
  • Vortex type Fluidic Device(FD) which is installed at the bottom of Safety Injection Tank(SIT) controls the discharge flow rate from the tank. In case of loss of coolant accident the injection water flows into primary system in two steps; initial high flow rate for certain period of time and subsequent low flow rate. By two-step control of the discharge flow rate, FD can ensure the effective use of water in the tank. A small-scale FD has been tested to obtain a required flow characteristics maintaining full pressure and height of prototype, which are the major contributing parameters. Through the testing of many different arrangements of internal geometry of FD, most appropriate one was selected and its performance data was obtained. As characteristics of FD, time dependent Euler number, flow rate and pressure are presented and discussed. Also a method to predict the full size FD is presented.

  • PDF

액체로켓엔진의 2단 시동에 관한 연구 (A Study on the 2-Stage Startup of Liquid Rocket Engine)

  • 박순영;조원국
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.324-327
    • /
    • 2008
  • Two stage startup of high thrust liquid rocket engine can reduce the abrupt impulse to the vehicle and engine by changing oxidizer flow rate to the combustion chamber. Also it ensures stable ignition of combustion chamber against hard start and to prevent pump stall by the sudden supply of large mass flow rate. However high discharge pressure of oxidizer pump or temperature rise in gas generator may be a problem in applying the preliminary stage. To solve this problem, we analyzed the effect of the slope of oxidizer pump's head curve and the oxidizer mass flow rate to combustion chamber during preliminary stage using the rocket engine startup analysis code. A moderate slope(${\circleddash}{\sim}$-3) of head curve and 80% mass flow rate during preliminary stage can reduce the oxidizer pump discharge pressure by 15 to 20% comparing with the condition of ${\circleddash}$=-4.37 head curve and 70% mass flow rate. Also it can maintain the turbine inlet temperature rise within 50K from the nominal value.

  • PDF

플라즈마중합막의제작과레지스트 특성에 관한 연구 (A Study on the Preparation and Resist Characterization of the Plasma Polymerized Thin Films)

  • 이덕출;박종관;한상옥;김종석;조성욱
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.802-808
    • /
    • 1994
  • The purpose of this paper is to describe an application of plasma polymerized thin film as an electron beam resist. Plasma polymerized thin film was prepared using an interelectrode capacitively coupled gas-flow-type reactor, and chosen methylmethacrylate(MMA)and methylmethacrylate-tetrameth-yltin(MMA-TMT) as a monomer. This thin films were also delineated by the electron-beam apparatus with an acceleration voltage of 30kV and an expose dose ranging from 20 to 900$\mu$C/cmS02T. The delineated pattern in the resist was developed with the same reactor which is used for polymerization using an argon as etching gas. The growth rate and etching rate of the thin film is increased with increasing of discharge power. Thin films by plasma polymerization show polymerization rate of 30~45($\pm$3) A/min, and etching rate of 440($\pm$30) A/min during Ar plasma etching at discharge power of 100W. In apparently lower than that of conventional PMMA, but the plasma-etching rate of PP(MMA-TMT) was higher than that of PPMMA.

  • PDF

$AB_5$계 수소저장합금의 Zr, Ti 및 V 첨가에 따른 전기화학적특성 (Electrochemical properties of $AB_5$-type Hydrogen alloys upon addition of Zr, Ti and V)

  • 김대환;조성욱;정소이;박충년;최전
    • 한국수소및신에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.31-38
    • /
    • 2006
  • There are two types of metal hydride electrodes as a negative electrode in a Ni-MH battery, $AB_2$ Zr-based Laves phases and $AB_5$ LM(La-rich mischmetal)-based alloys. The $AB_5$ alloy electrodes have characteristic properties such as a large discharge capacity per volume, easiness in activation, long cycle life and a low cost of alloy. However they have a relatively small discharge capacity per weight. The $AB_2$alloy electrodes have a much higher discharge capacity per weight than $AB_5$ alloy electrodes, however they have some disadvantages of poor activation behavior and cycle life. Therefore, in order to improve the discharge capacity of the $AB_5$ alloy electrode the Zr, Ti and V which are the alloying elements of the $AB_2$ alloys were added to the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}$ alloy which was chosen as a $AB_5$ alloy with a high capacity. The addition of Zr, Ti and V to $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}$ alloy improved the activation to be completed in two cycles. The discharge capacities of Zr 0.02, Ti 0.02 and V 0.1 alloys in $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) were respectively 346, 348 and 366 mAh/g alloy. The alloy electrodes, Zr 0.02, Ti 0.05 and V 0.1 in $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V), have shown good cycle property after 200 cycles. The rate capability of the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) alloy electrodes were very good until 0.6 C rate and the alloys, Zr 0.02, Ti 0.05 and V 0.1, have shown the best result as 92 % at 2.4 C rate. The charge retention property of the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) alloys was not good and the alloys with M content from 0.02 to 0.05 showed better charge retention properties.

부자 측정 시 식생을 고려한 유량산정에 관한 연구 (Discharge Computation from Float Measurement in Vegetated Stream)

  • 이태희;정성원
    • 대한토목학회논문집
    • /
    • 제39권2호
    • /
    • pp.307-316
    • /
    • 2019
  • 하도 내 식생발달은 흐름저항을 크게하여 홍수 시 하천 수위를 상승시키고 수위-유량관계의 변화에도 영향을 미치고 있다. 홍수 시 수위가 첨두에 도달하고 하강하여 하도 내 드러난 식생은 대부분 도복(倒伏, prone) 상태에 있다. 이렇게 식생이 도복상태로 되어있는 식생층 구간은 식생된 개수로 흐름의 유속분포를 고려하였을 때 유속이 0인 지점의 높이로 고려된다(Stephan and Guthnecht, 2002). 그러나 부자 측정에 의한 유량산정에 있어서 식생층 구간의 높이를 고려하지 않고 하상높이를 유하면적으로 적용하면 유량이 과대 산정되는 경향이 발생한다. 본 연구에서는 식생된 하천에서 정도 높은 유량을 산정하기 위해 영강의 점촌, 내성천의 향석 지점에서 홍수 후 식생층 높이를 측량하고 통수단면적에서 식생층 투영면적을 제외하여 유량을 산정하였다. 그 결과, 유량의 규모에 따라 차이는 있지만 최소 4.34 %에서 최대 10.82 %의 유량편차를 보였다. 따라서 홍수 시 통수단면적을 적용하여 유량을 산정하는 유속-단면적 방법에 있어서 식생하천에서 식생층 높이의 투영면적을 고려하여 유량을 산정한다면 좀더 적합한 유량산정이 이루어질 것으로 판단된다.

한 종합병원의 포괄수가제 실시 전후 수정체수술환자의 의료서비스 및 진료비 비교분석 (The Change of Medical Care Pattern and Cost of Cataract Surgery by the DRG Payment System in a General Hospital)

  • 이미림;이용환;고광욱
    • 한국병원경영학회지
    • /
    • 제10권1호
    • /
    • pp.48-70
    • /
    • 2005
  • The purpose of this study was to make an analysis of the impact of the DRG payment system on medical care pattern and cost of cataract surgery in a general hospital. The subjects were 173 patients whose DRG severity grade was zero, selected from among the hospitalized who underwent cataract surgery before and after the joining to the demonstrational operation of the third year DRG payment system. Their medical records and the details of their medical bills were examined to find out the length of hospital stay, medical care pattern provided to them, the cost of medical care, and the quality of medical care. The length of stay and the amount of medical care supplied during being in hospital dropped significantly for both single-eye and double-eyes cataract surgery groups. The amount of antibiotic use went down during the hospitalization and upon discharge from the hospital, but decreased after discharge. The total medical bills and the rate of basic examination implementation increased in the OPD before hospitalization but after discharge dropped. For double-eyes cataract patients, the rate of double-eyes cataract surgery went down. The total medical bills of DRG payment system converted into the fee-for-service system was greater by 113.3% for the single-eye cataract surgery group and by 102.9% for the doble-eyes cataract surgery group, compared to that by the fee-for-service. The contribution shared by the insurance corporation increased for both single-eye and double-eyes cataract surgery groups, but the copayment by the insured went down. Regarding the treatment outcome, no difference was found in complication rate, resurgery rate and mortality rate before and after the joining to the DRG payment system was implemented. The use of special lens lessened significantly. The amount of medical care supplied during hospitalization decreased but the complication rate didn't increase. But the increased use of low-price artificial cataract and the avoidance of double-eyes cataract surgery was observed. The phenomenon decreased number of OPD visit and the decreased total medical bills of OPD care after discharge in this hospital required further evaluation.

  • PDF

리튬이온 전지의 충방전 특성에 대한 전산 모델링 (Computational Modeling of Charge-Discharge Characteristics of Lithium-Ion Batteries)

  • 이대현;윤도영
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.278-285
    • /
    • 2011
  • 본 연구에서는 리튬이온 전지의 충 방전 특성에 관한 모델링과 전산모사를 수행하였다. 전지의 시스템 구성은 단순화된 2차원 형태의 단일셀에 대하여 모델링하였고, 공학적 편미분방정식 풀이자인 FEMLAB을 이용하여 288 K와 318 K 범위내에서 충방전 특성에 대한 열적 모델링을 수행하였다. 모델링에 채택한 물성치 변수들에 대하여 온도특성을 고려하였으며, 이를 통하여 전지의 특징적인 충방전의 사이클 변화와 충방전 전하량의 변화를 체계적으로 전산모사하였다. 그 결과 충방전 속도에 상관없이 충방전의 주기가 온도가 낮아질수록 짧아짐을 정량적으로 해석할 수 있었다. 이에 부가하여 전지내에서 리튬이온의 물질전달 현상을 해석하여, 전지의 충방전 특성과의 상관관계를 고찰하였다.