• Title/Summary/Keyword: Discharge Rate

Search Result 2,246, Processing Time 0.028 seconds

Speech signal processing in the auditory system (청각 계통에서의 음성신호처리)

  • 이재혁;심재성;백승화;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.680-683
    • /
    • 1987
  • The speech signal processing in the auditory system can be analysized based on two representations : Average discharge rate and Temporal discharge pattern. But the average discharge rate representation is restricted by the narrow dynamic range because of the rate saturation and the two tone suppression phenomena, and the temporal discharge pattern representation needs a sophisticate frequency analysis and synchrony measure. In this paper, a simple representation is proposed : using a model considering the interaction of Cochlear fluid-BM movement and a haircell model, the feature of speech signals (formant frequency and pitch of vowels) is easily estimated in the Average Synchronized Rate.

  • PDF

Characteristics of Material Removal Rate According to Discharge Area and Capacitance in MEDM (미세 방전 가공에서 방전 면적과 축전 용량에 따른 가공율 특성)

  • 박동희;류시형;김보현;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.183-190
    • /
    • 2003
  • In this paper, investigated are the machining characteristics such as material removal rate and machining time with respect to discharge area and capacitance in micro electrical discharge machining (MEDM). As discharge area determined by the electrode size and capacitance change, the optimal feedrate to allow the minimum machining time changes. The smaller discharge area is, the lower MRR becomes because of the area effect. As the capacitance increases, MRR also increases. However there is the limit capacitance beyond which the MRR does not increase anymore. As the discharge area increases, the limit capacitance also increases.

A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment (수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

An Experimental Study on the Estimation of Oil Discharge Rate from Inverter Rotary Compressor (인버터 로터리 압축기 오일 토출량 산정의 실험적 고찰)

  • Sin, Hyun-Seok;Byun, Soon-Seok;Tae, Sang-Jin;Moon, Je-Myung;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.28-32
    • /
    • 2011
  • The inverter rotary compressor discharges refrigerant and compressor oil in air-conditioning systems. The compressor oil which discharged form compressor decreases the efficiency of heat exchanger and affects the compressor operation. Recently, several studies are in progress for reducing the compressor oil. Before the reduction of compressor oil discharge rate, the quantitative measurement and evaluation method are required. In order to cope with this requirement we have developed the measurement technic of oil discharge rate. The reliability assessment was carried out approximately 0.1% of the errors with compressor performance indicators. The acceptable errors were to ensure the reliability of measurement technic. In the experiment results at several conditions, The oil discharge rate of heating operation has been confirmed average 3.7 times more than cooling operation. In this study the evaluation method and the experimental results of oil discharge rate in air-conditioning systems are presented with various operating conditions.

Effects of different Discharge Packs given at the Nursery Room on Postpartum Breast-feeding (신생아실에서의 모유 퇴원팩이 산후 모유수유 실천에 미치는 효과)

  • Choi Jayun;Kim Miwon
    • Child Health Nursing Research
    • /
    • v.1 no.1
    • /
    • pp.37-46
    • /
    • 1995
  • The effects of different discharge packs on the rate of breast-feeding practice were investigated in 2, 4 and 8 postpartal weeks. The subjects were those who have made delivery at Chonnam University Hospital from Jan to Feb 1994. They were divided into three groups by the discharge pack provided at the nursery room : the one group was given with formula discharge pack, another with breast-feeding discharge pack and the other nothing. The formula discharge pack contained formula samples, a feeding bottle and a pamphlet prepared by a formula company, and breast-feeding discharge pack contained a manual pump and a pamphlet made by Korean Nurses Association. Following results were obtained : 1. Different discharge packs significantly affected the rate of breast-feeding practice at 2 week postpartum, while not at 4 and 8 week postpartum. 2. At 2 week postpartum, the rate of breast-feeding practice was significantly higher in the group given with breast-feeding discharge pak than in that given with formula discharge pack. It was also significantly higher in the group given with breast-feeding discharge pack compared with the group given nothing. The breast feeding rate, however, did not significantly differ between the formula discharge pack group and the group given nothing. 3. The most common cause for the artificial feeding was 'lacking breast milk'. The most common cause to select a specific brand of formula milk was 'the same as in the nursery room'. In conclusion, it is suggested that encouraging mothers to perform breast feeding and providing them with a breast-feeding discharge pack instead of a formula pack at the nursery room are helpful in promoting the breast-feeding.

  • PDF

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

Decomposition of $SO_x, NO_x$ by Plasma Discharge (플라즈마 방전에 의한 $SO_x, NO_x$의 분해)

  • 우인성;강현춘
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.73-77
    • /
    • 1999
  • In this study, $SO_2$ and $NO_2$ reduction have been investigated by using coil type plasma reactor. The experiments have been carried out changing discharge power, gas flow rate frequency and electrode style to obtain the decomposition rate. Decomposition rates of $SO_2$ and $NO_2$ were obtained 20~98% at gas flow rate 100ml/min~1,000ml/min and discharge power 5~25w respectively. The energy efficiency is very good at the high frequency power. The decomposition rate of $SO_2$ for 5kHz power supply is only 90%, but for 10kHz power supply is very high, more than 98% for 15w. The decomposition rate is increasing according to the residence time or the power consumption of the discharge. About 15W discharge power for 17$cm^2$ reactor is necessary to obtain the decomposition rate of $SO_2$ and $NO_2$ of more than 85% or 98%. From these experiments, the consumption power of the decomposition rate of 98% in 300ppm $NO_2$ gas in nitrogen gas proved to be 18W and 300ppm $SO_2$ gas to be 15w.

  • PDF

A Study on Sediment Load in the Milyang River (유사량 산정에 관한 연구 (밀양강을 중심으로))

  • 안세영;민벙형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.4
    • /
    • pp.96-107
    • /
    • 1980
  • This study is carried out to estimate the rate of sediment transportation both to measure the amount of suspended and bedload sediment that moves on or near the river bed and passes through the cross section of a river in unit time, with suspended and bed load samplers used for the Milyang river and to determine the most satisfactory and convenient formula of some formulas for sediment discharge by comparing the measured rate with the calculated rate. The results of this study are summarized as follows; 1) The interrelationship (1) between the total discharge and the total sediment discharge (2) between discharge and suspended sediment load and (3) between discharge and bed load in the Milyang river are (1) i) 4$\leq$Q$\leq$100 C.M.S. Qr=0. 00272 Q0.70 (kg/sec) ii) 150$\leq$Q$\leq$800 C.M.S. Qr=0. 4807 Q0.46 (kg/sec) (2) Qs~=0. 07576 Q1.02 (kg/sec) (3) QB=0. 00957 Q0.44 (kg/sec) 2) The rate of suspended sediment load to total sediment discharge is found to be about; 99%. The suspended load is shown to be almost wash load which consists of silt and clay. 3) The relation between the total discharge and the suspended sediment load that are measured at three medium and small rivers in Korea is Qs=0. 13831 Q0.97 (kg/sec) 4) Brown's formula is determined to be the most convenient formula for application and comparison with observed data obtained for the Milyang river.

  • PDF

The Characteristics of Decomposition of NOx by Superposing Discharge Plasma Reactor (중첩 방전 반응기에 의한 NOx의 분해 특성)

  • ;;;;;山常 端樹
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.32-37
    • /
    • 1999
  • The superposing effect of SPCP(Surfoce Induced Plasma Chemical Process) and corona discharge has been studied for rerroval of NOx from industrial flue gases. NOx rermval rates by SPCP, corona discharge and superposing discharge were monitored and compared. Parameters were the concentration and the flow rate of gas, frequency and the type of discharge. Experirrental results showed that NOx removal rate by sUIffPOSing discharge was 10-15[%] higher than that by the other two modes. The higher NOx. rermval rate was observed with the lower frequency of upper electrode in the combined reactor and with the higher frequency of lower electrode. 'The maximum obtainable NOx. rerroval rate by SPCP (18 [W]) and corona discharge (8.5 [W]) was 80[%] and 10[%], respectively. With the combination of the two modes, however, 90[%] of NOx removal rate was observed with the discharge power of 14 [W].14 [W].

  • PDF

Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve (정유량 밸브의 카트리지의 오리피스 구멍의 유출계수)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Yang, Eui-Seok;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF