Urban Hydrologic Monitoring due to Internet Hydrologic Monitoring System (인터넷 수문관측시스템을 이용한 도시수문 모니터링)

  • Seo, Kyu Woo;Kim, Nam Gil;Na, Hyun Woo;Lee, In Rock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1321-1325
    • /
    • 2004
  • The continuous monitoring of the runoff in the small-scaled urban watershed and easily accessible experiment catchment is necessary to investigate the overall status of the development in the urban catchment and the varying aspects of the discharge characteristics due to the urbanization. However, the research on the management and the characteristics of the small-scaled model basin for discharge tests has not been actively performed up to now. This study selects the Dong-Eui university basin, which locates at Gaya-dong in Busan, as the experiment catchment to monitor the discharge rate in the urban watershed. EMS(DEMS, DATA-PCS EMS, mini rain gage & AWS(AWS-DEU, DATA-PCS AWS) monitoring system installed for the collection of hydrological data such as the rainfall and the waterlevel. This experiment catchment is the typical urban catchment and is under development, and it is possible to analyze the varying aspects of the discharge rate during and after the development.

  • PDF

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF

A study on the Production of Ozonized Water for Environment Improvement by Gaseous Discharge (기체방전을 이용한 환경개선용 오존수 제조에 관한 연구)

  • Lee, C.H.;Soong, H.J.;Yoon, B.H.;Kim, J.H.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.192-193
    • /
    • 2006
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating (1) discharge characteristics with variation of output voltage power supply, flow rate and gap distance (2) ozone generation and solubility characteristics with variation of flow rate, gap distance and discharge power. Pure oxygen was used as process gas of the co-axial type ozonizer.

  • PDF

Optimization of Design of Plasma Process for Water Treatment using Response Surface Method (반응표면분석법을 이용한 수처리용 플라즈마 공정 설계의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.617-624
    • /
    • 2011
  • In order to confirm the creation of the OH radical which influences to RNO bleaching processes, it experimented using laboratory reactor of dielectric barrier discharge plasma (DBDP). The experiments performed in about 4 kind process variables (diameter of ground electrode, diameter of discharge electrode, diameter of quartz tube and effect of air flow rate) which influence to process. In order to examine optimum conditions of design factors as shown in Box-Behnken experiment design, ANOVA analysis was conducted against four factors. The actual RNO removal at optimized conditions under real design constraints were obtained, confirming Box-Behnken results. Optimized conditions under real design constraints were obtained for the highest desirability at 1, 1 mm diameter of ground and discharge electrode, 6 mm diameter of quartz tube and 5.05 L/min air flow rate, respectively.

Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process (무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향)

  • 정재우;이용환;박경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

Effect of discharge power and pressure in deposition of diamond thin films by MWPECVD (MWPECVD법에 의한 Diamond박막 성장에 있어서 방전전력과 압력의 영향)

  • Rho, Se-Yeol;Choi, Jaog-Kyu;Park, Sang-Hyun;Park, Jae-Yun;Koh, Hee-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.132-135
    • /
    • 1992
  • Diamond thin films by MWPECVD in methane-hydrogen mixed gas were studied, with emphasis on the investigation of the effect of discharge power and pressure. As a result, the growth rate of diamond thin films was affected by discharge power and the surface morphology of diamond thin films was affected by pressure. The growth rate of diamond films was about 1.65 ${\mu}m$/hr under the condition of MW power: 900W, pressure: 60torr, $H_2$ flow rate: 60sccm, $CH_4$ concentration: 1 % and deposition time: 5hr. The deposited diamond films were identified by SEM, XRD and Raman spectrophotometer.

  • PDF

Particle Simulation on the Effect of Grid Cathode Geometry in SCBF Device (SCBF 장치에서 그리드 음극 구조의 영향에 대한 입자 시뮬레이션)

  • Ju, Heung-Jin;Park, Jeong-Ho;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.742-747
    • /
    • 2007
  • In 2-dimensional SCBF (Spherically Convergent Beam Fusion) device, the effect on neutron production rate of the grid cathode geometry was simulated. The motion of Particles was tracked using Monte Carlo Method including the atomic and molecular collision processes and potential distribution was calculated by Finite Element Method, Main processes of the discharge were the ionization of $D_2$ by fast $D_2^+\;ion$. As the number of cathode rings was small and the size of grid cathode decreased, the ion current increased and neutron production rate will also increase. The star mode discharge which is a very important characteristic in SCBF device, was confirmed by the ionization position.

Atmospheric Pressure Plasma Ashing of Photoresist Using Pin to Plate Dielectric Barrier Discharge

  • Park, Jae-Beom;Oh, Jong-Sik;Yeom, Geun-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1500-1503
    • /
    • 2009
  • In this paper, we studied about atmospheric pressure remote plasma ashing of photoresist(PR), by using a modified dielectric barrier discharge(DBD). The effect of various gas combinations such as $N_2/O_2$, $N_2/O_2+SF_6$ on the changes PR ashing rate was investigated as a function of power. The maximum PR ashing rate of 1850 nm/min was achieved at $N_2$ (70 slm)/ $O_2$ (200 sccm) + $SF_6$ (3 slm). We found that as the oxygen and fluorine radical peaks were increased, the ashing rate is increased, too.

  • PDF

Experimental Study on Air Decomposition By-Product Under Creepage Discharge Fault and Their Impact on Insulating Materials

  • Javed, Hassan;LI, Kang;Zhang, Guoqiang;Plesca, Adrian Traian
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2392-2401
    • /
    • 2018
  • Creepage discharge faults in air on solid insulating material play a vital role in degradation and ageing of material which ultimately leads to breakdown of power equipment. And electric discharge decompose air in to its by-products such as Ozone and $NO_x$ gases. By analyzing air decomposition gases is a potential method for fault diagnostic in air. In this paper, experimental research has been conducted to study the effect of creepage discharge on rate of generation of air decomposition by-products using different insulating materials such as RTV, epoxy and fiberglass laminated sheet. Moreover XRF analysis has been done to analyze creepage discharge effect on these insulating materials. All experiments have been done in an open air test cell under constant temperature and pressure conditions. While analysis has been made for low and high humidity conditions. The results show that the overall concentration of air decomposition by-products under creepage discharge in low humidity is 4% higher than concentration measured in high humidity. Based on this study a mathematical relationship is also proposed for the rate of generation of air decomposition by-products under creepage discharge fault. This study leads to indirect way for diagnostic of creepage discharge propagation in air.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.