• Title/Summary/Keyword: Discharge Mode

Search Result 292, Processing Time 0.026 seconds

The PV MPPT & Charge and Discharge Algorithm for the Battery Included Solar Cell Applications (배터리 내장형 초소형 태양광 장치용 PV MPPT 및 충방전 제어 알고리즘)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lae, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.69-75
    • /
    • 2013
  • To increase the efficiency of the photovoltaic, almost photovoltaic appliances are controlled by Maximum Power Point Tracking(MPPT). Existing most of the PV MPPT techniques have used power which multiplies sensed output current and voltage of the solar cell. However, these algorithms are unnecessarily complicated and too expensive for small and compact system. The other hand, the proposed MPPT technique is only one sensing of the MPPT converter's output current, so there is no need to insert another sensors of battery side. Therefore, this algorithm is simpler compared to the traditional approach and is suitable for low power solar system. Further, the novel proper charge/discharge algorithm for the battery with PV MPPT is developed. In this algorithm, there is CC battery charge mode and load discharge mode of the PV cell & battery dual. Also we design current control to regulate allowable current during the battery charging. The proposed algorithm will be applicable to battery included solar cell applications like solar lantern and solar remote control car. Finally, the proposed method has been verified with computer simulation.

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge (정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

A Study on the Signal Propagation Characteristics of Generator Windings (발전기 권선에서의 신호전송 특성에 관한 연구)

  • Hwang, Don-Ha;Kim, Jin-Bong;Kim, Yong-Joo;Park, Myong-Soo;Kim, Taek-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF

Simulation on a Residential Heat Pump System Using $CO_2$ (이산화탄소를 적용한 주거용 냉난방 겸용 열펌프 시스템의 시뮬레이션)

  • 조홍현;이무연;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.987-995
    • /
    • 2003
  • The performance of a residential heating and cooling system with $CO_2$ is predicted by using a cycle simulation model. The simulations are conducted by varying design parameters and operating conditions. The efficiency of the transcritical cycle can be improved by utilizing the advantages in heat transfer characteristics of $CO_2$ and developing microchannel indoor and outdoor heat exchangers. For the designed system of this study, the predicted COP of the heat pump system is approximately 3.5 in the heating mode and 3.0 in the cooling mode. The predicted optimal discharge pressure for the heat pump system is approximately 11 MPa in the heating mode and 9 MPa in the cooling mode.

MINIMUM BATTERY ENERGY IN THE SURVIVAL MODE FOR THE COMS SPACECRAFT

  • Koo, Ja-Chun;Ra, Sung-Woong
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.96-99
    • /
    • 2008
  • The MRE (Monitoring Reconfiguration Electronics) board included inside the SCU (Spacecraft Computer Unit) in the COMS (Communication, Ocean and Meteorological Satellite) spacecraft is used to monitor the battery voltage and to detect a battery under voltage (low battery capacity) or a battery overvoltage (overcharge). In case of alarm detection, a reconfiguration is initiated by the MRE board. The MRE configures the overall spacecraft in the survival mode to protect the Li-Ion (lithium ion) battery from overcharge and over discharge. For the EPS (Electrical Power Subsystem) point of view, the survival mode can be trigged from hardware wired thresholds. The aim of this paper to provide and to justify the low and high threshold levels which are associated to the MRE battery voltage monitoring. The MRE trig guarantees minimum battery energy to available for the required 48 hours autonomy duration of the spacecraft after MRE trig in the survival mode.

  • PDF

Acoustic Mode Analysis to Identify Cavity Noise of Scroll Compressor (스크롤 압축기의 공동 소음 규명을 위한 음향모드 분석)

  • Kim, Seung-Yup;Lee, Dong-Soo;Suh, Jeong-Hwan;Heo, Dae-Nyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.83-88
    • /
    • 2004
  • Acoustic modes of internal region of 4-hp scroll compressor are identified by measuring transfer functions between a reference and 84 measuring points. The corresponding acoustic mode-shapes and natural frequencies were calculated by analysis software SYSNOISE. There exist two clearly distinguishable dipole modes of vertical and horizontal direction and a single quadrupole mode in the frequency region of interest. It shows that the natural frequencies of the identified modes are linearly sensitive to suction pressure (Ps) but relatively in sensitive to discharge pressure (Pd) in operating condition.

  • PDF

A Study on Color Control in Gas Discharge Tube with the Variation of Frequency (주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구)

  • Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Modification of Polymer Surface by Corona Discharge and the Subsequent Graft Polymerization of Acrylamide (코로나 방전처리와 아크릴아미드 그라프트 중합에 의한 고분자 표면개질)

  • 김형우;김찬영;박병기
    • Textile Coloration and Finishing
    • /
    • v.5 no.1
    • /
    • pp.26-32
    • /
    • 1993
  • This study is concerned with the graft polymerization of acrylamide onto the surfaces of polyethylene and polyethylene terephthalate films treated with on corona discharge. In the case, peroxides formed by the corona discharge treatment are likely to be the species responsible for initiating the graft polymerization. This treatment produced a continuous charge in wettability and also amid group density on the polymer surface, as evidenced by water contact angle measurement, Fourier-transform infrared spectroscopy in the attenuated total reflectance mode, and electron spectroscopy for chemical analysis. Both of the merely corona-treated film and the subsequently grafted film are discussed as a function of time after treatment and water washings.

  • PDF