• 제목/요약/키워드: Discharge Load Density

검색결과 32건 처리시간 0.02초

비점오염원 관리지역의 선정 기법에 관한 연구 (A Study for the Selection Method of Control Area of Nonpoint Pollution Source)

  • 박상현;정우혁;이상진;임봉수
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정 (Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake)

  • 김동우;장미정;한인섭
    • 대한환경공학회지
    • /
    • 제36권5호
    • /
    • pp.367-377
    • /
    • 2014
  • 국내 최대 상수원인 팔당호는 하천형 호소로 분류되며, 팔당호 수질은 외부오염원의 영향이 크다. 이에 본 연구에서는 팔당호 상류지역의 오염원 분포와 오염물질 유출특성을 분석하여 BOD와 TP 관리를 위한 중점관리 오염원을 선정하고자 하였다. 이를 위해 11개 단위유역에 대한 오염원별 발생부하량과 배출부하량을 조사하고, 74개 소하천의 수질 유량 측정결과를 이용하여 유달부하량과 유역면적당 유달부하 밀도를 분석하였다. 오염원별 BOD, TP 발생부하량과 배출부하량, 유달부하량을 분석한 결과, BOD 발생부하량은 축산계가 66.0%로 가장 높은 비율을 차지하였고, BOD 배출부하량은 생활계가 42.7%를 차지하였으며, BOD 유달부하량은 축산계와 생활계가 각각 36.4%, 34.3%를 차지하는 것으로 나타났다. TP 발생부하량과 배출부하량, 유달부하량 모두 축산계에서 가장 높은 비율을 차지하였으며, 각각 82.5%, 44.4%, 46.7%로 나타났다. 또한 BOD 유달부하밀도는 인구밀도가 높은 경안천 유역이 $14.6kg/km^2/d$으로 가장 높았고, TP 유달부하밀도는 가축사육두수가 많은 청미천 유역이 $1.23kg/km^2/d$이 가장 높게 나타났다. 이러한 연구결과를 통해 팔당호 수질개선을 위해서는 생활오수와 가축분뇨를 중심으로 오염원관리가 필요하며 경안천 유역은 생활오수에 대한 관리가 필요하고 남한강 유역, 특히 청미천 유역은 가축분뇨에 대한 관리가 필요한 것으로 판단되었다.

수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로 (Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin)

  • 박준대;최옥연;오승영
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

다변량통계분석을 이용한 수질오염총량관리 단위유역별 오염물질 배출특성 분석 - 한강수계를 중심으로 - (A Study on the Spatial Strength and Cluster Analysis at the Unit Watershed for the Management of Total Maximum Daily Loads)

  • 최옥연;김기훈;한인섭
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.700-714
    • /
    • 2015
  • The characteristic of the water quality and pollutant discharge was analyzed at the units watershed of the total amount management in Han-river basin, and after classified in a similar area by multivariate statistical analysis, the main trend such as the water quality trend and pollutant discharge characteristic were analyzed. As a result of this study, the density of the pollutant at the unit watershed is not necessarily identified as discharge density, and the primary management watershed and targeted substances were analyzed depending on the operating status of the environmental infrastructure in watershed and the main pollution factor and discharge path per pollutants. As a result of cluster analysis, watersheds were classified into four groups according to discharge characteristics. It will be used when selecting target area of primary management that is appropriate to the characteristics of each river and establishing efficient water quality improvement plans.

충청남도 4대수계 주요 지류하천 수질 모니터링을 통한 유역 관리 방안 (Watershed Management Plan through Water Quality Monitoring for Main Branches of 4 Water Systems in Chungcheongnamdo)

  • 박상현;김홍수;조병욱;문은호;최진하
    • 한국물환경학회지
    • /
    • 제32권2호
    • /
    • pp.163-172
    • /
    • 2016
  • This study aimed to develop a plan for effective performance of a watershed through correct identification of a river watershed by using the flowrate of the river and water quality data, which is the basis for the establishment of the water environment policy. The target river for water quality improvement was selected based on the monitoring result for 4 water systems in Chungcheongnamdo province in the recent 3 years. The result of analysis for the distribution of discharge capacity by a pollution source group for the water quality improvement target river showed that most of the target river has a high discharge capacity in the water system for living and livestock. Analysis for the density of the total discharge capacity of the whole watershed of Chungcheongnamdo indicated that the river that needs water quality improvement has high BOD concentration and high discharge load density at the point that this river is located. Thus, for efficient watershed management through selection and concentration, Chungcheongnamdo needs to improve the target river in priority. Stepwise planning is also required to establish and execute the water quality improvement in order to satisfy said target water quality, and establish the index for the water improvement rate for its evaluation.

식생대에서 유사의 퇴적과 하도변화 수치모의 분석 (Numerical analysis of deposition and channel change in the vegetation zone)

  • 황효;장창래;강민석
    • 한국수자원학회논문집
    • /
    • 제56권1호
    • /
    • pp.23-34
    • /
    • 2023
  • 본 연구에서는 실내실험과 수치모의를 통해 식생대에서의 소류사 이동 및 하도 변화를 분석하였다. 실내시험에서 식생대의 영향을 검토하기 위해 아크릴 봉으로 제작한 인공 식생대를 실험수로에 설치하였으며, 유량 조건을 조정하여 유량변화에 따른 식생대에서의 소류사 이동 및 하도 변화를 검토하였다. 다음으로 실내실험과 동일한 조건을 2차원 수치 모형인 Nays2D모형에 적용하여 수치모의를 수행하고, 그 결과를 실내실험 결과와 비교하여 수치모형의 적용성을 검토하였다. 마지막으로 적용성을 검토한 수치모형을 적용하여 식생밀도의 변화에 따른 소류사 이동 및 하도의 변화를 검토하였다. 실내실험과 수치모형을 적용하여 유량변화에 따른 식생대에서의 소류사 이동 및 하도 변화를 검토한 결과, 두 적용 방법의 결과가 유사하게 나타났다. 유량이 증가함에 따라 상류에서 유입된 소류사가 식생대 내부에 퇴적되었으며, 식생대 반대편에는 흐름이 집중되어 침식이 발생하였다. 또한 시간이 지날수록 하류방향으로 침식범위가 증가하였다. 식생밀도의 변화에 따른 소류사 이동 및 하도의 변화를 검토한 결과, 식생대의 식생밀도가 증가할수록 상류에서 유입된 소류사가 식생대 내부에 퇴적되었다. 또한 식생밀도의 증가로 인하여 흐름이 식생대의 반대편으로 집중되어 식생대 반대편 하도의 침식이 발생하였다.

유량-수질관계 비교를 통한 하천 수질개선 우선순위 선정기법 적용 (Application of Priority Order Selection Technique for Water Quality Improvment in Stream Watershed by Relationship of Flow and Water Quality)

  • 임봉수;조병욱;김영일;김도영
    • 대한환경공학회지
    • /
    • 제32권8호
    • /
    • pp.802-808
    • /
    • 2010
  • 본 연구는 하천 수질개선을 위해 충청남도 금강 중 하류권역에 위치한 18개의 지류하천을 대상으로 유량 및 수질측정, 하천그룹화, 오염물질 부하량 및 배출부하밀도를 산정하였다. 하천의 수질분석 결과는 저수기의 평균BOD농도를 기준으로 하천생활환경기준 II등급(BOD기준 3.0 mg/L)의 수질을 초과하는 하천은 정안천, 방축천, 길산천, 조천, 석성천, 강경천으로 나타났다. 하천그룹화 결과 금강에 유입되는 유량이 저수량을 기준으로 $10\;m^3/min$ 이상이고, 저수기의 평균BOD 농도가 3.0 mg/L 이상으로 금강의 수질을 악화시키는 주된 요인인 그룹(Group A)에 해당되는 하천으로는 조천, 강경천, 석성천, 정안천으로 나타났다. 이 하천들은 금강의 수질개선을 위해서 수환경관리의 대책을 가장 먼저 고려해야 할 것이다. Group A에 해당하는 하천 중 배출부하밀도가 10 BOD kg/$day{\cdot}km^2$ 정도 이상인 하천은 조천, 석성천, 강경천으로 나타났다. 하천의 유량 및 수질모니터링, 하천그룹화, 배출부하밀도산정 등을 통하여 수질개선 우선순위 유역을 선정한 결과, 연기군의 조천, 부여군과 논산시 경계에 위치한 석성천, 논산시의 강경천과 같은 하천 유역이 수질개선이 시급한 것으로 나타났다.

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.