• Title/Summary/Keyword: Disc Insertion

Search Result 34, Processing Time 0.026 seconds

A Biomechanical Analysis of an Interspinous Distraction Device for Treatment of Lumbar Spinal Stenosis (요추부 협착증 치료를 위한 극돌기 삽입술의 생체역학적 효과 분석)

  • Lee Hui-Sung;Chen Wen Ming;Song Dong-Ryul;Kwon Soon-Young;Lee Kwon-Yong;Lee Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.210-217
    • /
    • 2006
  • Many types of interspinous distraction devices (IDDs) have been recently developed as an alternative surgical treatment to laminectomy and fusion with pedicle screws for the treatment of the lumbar spinal stenosis (LSS). They are intended to keep the lumbar spine in a slightly flexed posture to relieve pain caused by narrowing of the spinal canal and vertebral foramen. However, their biomechanical efficacies are not well known. In this study, we evaluated the kinematic behaviors and changes in intradiscal pressure (IDP) of the porcine lumbar spine implanted with IDD. For kinematics analysis, five porcine lumbar spines (L2-L6) were used and the IDD was inserted at L4-L5. Three markers (${\phi}{\le}0.8mm$) were attached on each vertebra to define a rigid body motion for stereophotogrammetric assessment of the spinal motion in 3-D. A moment of 7.5Nm in flexion-extension, lateral bending, and axial rotation were imparted with a compressive force of 700N. Then, IDD was implanted at L3-L4. IDPs were measured using pressure transducer under compression (700N) and additional extension moment (700N+7.5Nm). In kinematic behaviors, insertion of IDD resulted in statistically significant decrease 42.8% at the implanted level in extension. There were considerable changes in ROM at the adjacent levels, but statistically insignificant. In other motions, there were no significant changes in ROM as well regardless of levels. IDPs at the surgical level (L3-L4) under compression and extension moment decreased by 12.9% and 18.8% respectively after surgery (p<0.05). At the superiorly adjacent levels, IDPs increased by 19.4% and 12.9% under compression and extension, respectively (p<0.05). Corresponding changes at the inferiorly adjacent levels were 29.4% and 6.9%, but they were statistically insignificant (p>0.05). The magnitude of pressure changes due to IDD, both at the operated and adjacent levels, were far less than the previously reported values with conventional fusion techniques. Our experimental results demonstrated the IDDs can be very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramens while maintaining kinematic behaviors and disc pressures at the adjacent levels.

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.

A Study on the Demand for Equipent Development in Nursing (간호기기 개발수요 조사연구)

  • Chang, Soon-Book;Kim, Eui-Sook;Whang, Ae-Ran;Kang, Kyu-Sook;Suh, Mi-Hae
    • The Korean Nurse
    • /
    • v.35 no.2
    • /
    • pp.71-91
    • /
    • 1996
  • The objectives of thes study were to identify the need for equipment development in nursing, and to determine the priorities for that development. The study was descriptive study done between March 2 and May 30, 1995, in which the subjects, including 421 patients, 223 family members, and 198 nurses from neurosurgery, orthopedic, rehabilitation medicine, internal medicine and intensive care units of nine general hospitals in Seoul, completed a questionnarie developed by the research team. The questionnaire consisted of 35 open and closed questions. Data was analyzed using frequencies and percentages. The results ware summarized as follows: 1) The average age of the nurses was 27.9 years, 48% of the patients were between 20 and 40 years of age, and 17% were over 60. The average lingth of experience for the nurse subjects was four years five months with 36.9%. having over five years experience. The most frequent diagnoses of patients were spinal disc(35.9%), internal medicine disease(26.0%), cerebral vascular accident(16.6%) and spinal cord injury(10%) 2) Many of the nurses(96.4%) reported deficiencies with existing equipment and 96.5% of the nurses, but only 79.8% of the patients, nurses' time. Further, 82.3% of the nurses and 75.8% of the patients felt that the development of new equipment would lead to a decrease in the cost of nursing care. 3) Nurses felt that the greatest areas of inconvenience were patient feeding(71.7%), hygiene(71.2%), caring for a patient confined to bed(70.7%), patient clothing(67.2%), mobility transfers(63.5%) and urinary elimination(52.0%). However, patients and family members listed the following as being the most inconvenient: urinary elimination(58.7%), Hygiene(50.5), feeding(48.4%), mobility transfers(47.1%) and bed care(45.2%). 4) Generally the nurses listed more inconveniences and patients and family members listed more demands for the development of equipment. These included utensils with large handles, and regulators for tube feedings; mattresses that provide for automatic position change and massage, which have patient controlled levers and a place for bed pan insertion; automatic lifts or transfer from bed to wheelchair; equipment to facilitate washing and oral hygiene as well as equipment that will allow patients with spinal cord injuries easy access to showers; a bed pan/urinal for women that is comfortable and effective from which urine can be measured and disposed of easily; disposable dressing sets and tracheostomy care sets and a convenient way of measuring changes in wound size; a safe delivery system for oxygen, a variety of mask sizes and better control of humidity, tracheal material than at present, as well as a communication system for patients with tracheostomies; clothing that will allow access to various parts of the body for treament or assessment without patients having to remove all of their clothing; and finally a system that will allow the patient to control lighting, telephones and pagers. Priority areas for equipment development reported by the nurses were, urinary elimination(58. 7%), hygiene(50.5%), feeding(48.4%), mobility transfers(47..1%), bowel elimination(40.8%). Those reported by the patients family members were feeding(71.7%), hygiene(70.0%), bedcare(70.7%), clothing(67.2%), mobility transfers(63.6%), urinary elimination(52.9%) and bowel elimination(50.5%) Altogether, nurses, patients and family members listed the following as priorities; clothing (178), bed care(144), urinary elimination(92), environment(81), hygiene(70). Further, a health professional forum listed urinary elimination, oxygen delivery, medication delivery, mobility transfers, bed care and hygiene in that order as priority areas. From this study it can be concluded that the first need is to develop equipment that will address the problems of urinary elimination. To do (l)This nurses who are interested in equipment development should organize an equipment development team to provide a forum for discussion and production of equipment for nursing.

  • PDF

Characteristics of New Microsporidia S80 Isolated from Silkworm, Bombyx mori L. in Korea (가잠(家蠶)으로부터 분리(分離)된 새로운 Microsporidia S80의 특성(特性))

  • Lim, Jong Sung;Cho, Sae Yun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.67-83
    • /
    • 1983
  • The new microsporidia S80 isolated from, Bombyx mori L. in Korea showed ovoid in the morphology of the spores and the size were measured $2.9{\pm}0.28{\mu}$ in length and $1.7{\pm}0.29{\mu}$ width. No other microsporidian spore like this has not been so far isolated from Silkworm. The length of the polar filament extruded in hydrogen peroxide ($H_2O_2$) at $30^{\circ}C$ was $26{\mu}$ of a round cytoplasm on the top. The spores were partly stained with Giemsa, Safranin-O and Gram as the same staining properties as Nosema bombycis, Microsporidia K 79 and other microsporidian spores. The fine structures were observed under scanning eleceron microscope through ultrathin sectioning. The spore wall was composed of three layers ; the thin exospore of an electron dense rippled layer, the thick electron lucent endospore which was thinning considerably at the polar filament insertion point, and the inner limiting membrane. Polar cap present at the sporeapex, with a long polar filament of 12-13 coils, subtending angle of $60^{\circ}$ to spore axis, which is tubular made up of a multilayered and are a benes core, light ring structure enclosing the dance core, the dark ring structure enclosing the inner light ring structure and the other than and light ring structure bounded from cytoplasm. Lamellate polaroplast occupied the anterior part of the spore, and the two neclei with dense nucleoplasm bounded by a double nuclear envelope were cited in the slight downer middle portion of spore. From the characteristics of the shape, size and fine structures, it is certain to reason the Microsporidia S80 belong to the phylum Microspora, class Microspora, order Microsporida, order Microsporida. The shape of two nuclei cited seems to be genus Nosema, but in the classification for the suborder it should be defined wheather pansporoblasts be formed or not and for the genis especial attempts have been made to define the characters which distinguish the disporous genera in the life cycle. Survey through the infection of the bad cocoons during 1980 to 1982 in South Korea the areas contaminated with new microsporidia were revealed 5 provinces of Kyung-Gi, Kang-Won, Chung-Nam and Chun-Nam. Pathological effects inoculated per os at second instar larvae of silkworm, the LD 50 was $7.1{\times}10^7/ml$ as lower pathogenecity than that of Nosema bombycis Naegeli of $1.2{\times}10_7/ml$. While on the other hand the inoculation of the microsporidia at fourth instar larvae lowerd the whole cocoon weight and cocoon shell weight and significant at 1% level. The microsporidia S80 defined it can not be transmitted transovarially from the result of predictive and collective examination of 21 egg batches from the infected female moth.

  • PDF