• Title/Summary/Keyword: Disc

Search Result 3,934, Processing Time 0.035 seconds

Study in Minimum of Edge Bump using the Chamfer Angle in Blu-ray Disc Cover layer Spin Coating Process (블루레이 디스크의 커버 레이어 스핀코팅 시 챔퍼각을 이용한 끝단 범프 최소화 연구)

  • Lee, H.G.;Son, S.K.;Cho, K.C.;Shin, H.G.;Kim, B.H.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.178-183
    • /
    • 2006
  • A Blu-ray disc, which has a more than 25GB optical capacity, has been known as a promising next-generation optical disc format. It commonly has a 1.1 mm thick substrate and a 0.1 mm thick cover layer for beam transmitting and the protection of the reflecting surface. The cover layer is generally formed by the spin coating process. However, in conventional spin coating, small bumps are formed along the rim of the disc, which results in the fatal reading error. Numerical simulation of the thin film flow behaviors during spin coating with the commercial solver and optimal spinning conditions was obtained. Thickness distribution of the cover layer according to the variation of substrate's edge shape could be calculated as well. By modifying the shape of the substrate edge shape, the bumps along the disc rim could be minimized, and it was proved that the chamfered edge, around $5{\sim}10$ degree, is the simplest and most effective way to minimize the bumps.

  • PDF

The Relationship between Cervical Intervertebral Space in X-ray and Herniated Disc in CT (X-ray상 경추 추체간 간격과 CT상 경추 추간판 탈출증의 상관관계에 대한 고찰)

  • Shin, Woo-Suk;Jung, Dong-Hoon;Park, Won-Hyung;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.4
    • /
    • pp.75-81
    • /
    • 2015
  • Objectives To investigate the relationship between cervical intervertebral space narrowing in the X-ray and HIVD level of cervical spine in the CT image. Methods We studied 101 subjects who were taken cervical spine X-ray and CT. Intervertebral space were measured at the anterior, middle and posterior portion of each cervical disc in the X-ray. Considering individual difference, intervertebral space was set as value divided by upper width of lower vertebral body. We analyzed statistically adjusted intervertebral space of normal group and herniated disc group using student' t t-test. Results Intervertebral space of cervical spine was narrowed in the herniated disc group. But there was no significant difference at C2~C3. Conclusions We found that narrowing intervertebral space of cervical spine is associated with herniated disc. Further clinical observation is needed.

Two Cases of Disc Internal Disruption Syndrome (추간판 내부 파열 증후군(Internal disc disruption) 2례)

  • Lee, Jong-Hyeung;Ahn, Myun-Whan;Ahn, Jong-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.238-245
    • /
    • 1991
  • The disc internal disruption syndrome is not well known to us, but the following hypothesis is widely accepted in clinical practice. The disc internal disruption syndrome may develop intractable back pain with aggrevated of pain, loss of spinal motion with any physical exercise, leg pain, loss of energy, marked weight loss, and profound depression. The patient with this syndrome will be found to have normal plain roentgenograms, myelograms, CT scans, results of blood examination and neurologic findings. For these reasons, this syndrome was frequently diagnosed by abnormal discographic findings. We had experience with two cases of disc internal disruption syndrome with clinical, roentgenographic and discographic evaluations. Thus We present these cases with a brief review of the concerned literature.

  • PDF

A Case Report on the Treatment of Acute Anterior Disc Displacement without Redution in TMJ Disorders by Direct Trauma (직접외상에 의한 급성 비정복성 관절원판 변위의 치험례)

  • 조수현;고명연
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.281-288
    • /
    • 1998
  • The authors treated a 30-years old female patient who visited the Department of Oral Medicine, PNUH due to the chief complaint of limitation of mouth opening. The magnetic resonance imaging following clinical examination was used for establishing an accurate and reliable diagnosis and the patient was diagnosed as having anterior disc displacement without reduction in the right joint and anterior disc displacement with reduction in the left joint. For managing acute anterior disc displacement without reduction, mandible manipulation was applied first focusing on pain control and then stabilization appliance was used for maintenance of joint stabilization. With time, the sign and symptom was remarkably reduced and an active exercise program was recommended to maintain of normal muscle length, increase joint range of motion and develop normal coordination arthrokinematics. As a result of treatment, the patient did not complain discomfort of normal daily activities and it was difficult to consider that the displace disc was not reduced completely, but the improvement in range of motion and joint mobility were remarkably found. Therefore, an exercise program should be considered to maintain joint mobility and be effective as a self-care.

  • PDF

Experimental Study on the Opening Characteristics for Swing Check Valves (스윙형 역지 밸브의 열림 특성에 관한 실험적 연구)

  • Song, Seok-Yoon;Kim, Yang-Seok;Park, Sung-Keun;Hong, Sung-Yull
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.555-561
    • /
    • 2003
  • The experimental apparatus is designed and installed to measure the disc positions with flow velocity, $V_{open}\;and\;V_{min}$ for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as $V_{open}\;and\;V_{min}$ is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, $V_{min}$ is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is idly opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the $V_{min}$ velocities for 3 inch and 6 inch swing check valves are about 15.6% and 4.8% higher than the $V_{open}$ velocities, respectively. Although the experiments were done with the stable uniform flow, additional experiments will be performed to determine the effects of the upstream disturbances.

  • PDF

Thermal Fluid Flow and Deformation Analysis of Medium Commercial Vehicle Ventilated Brake Disc in Braking (중형 상용차 통풍형 브레이크 디스크의 제동 시 열 유동 및 변형 해석)

  • Kang, Chaeuk;Choi, Gyoojae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.63-69
    • /
    • 2014
  • Domestic automobile companies have adopted drum type brake system for commercial vehicles. However recently those companies have been applying disc-brake system to solve vehicle control-instability and inefficient heat discharge performance of conventional drum brake system for a medium commercial vehicle. Because the kinetic energy of a running commercial vehicle is relatively high, the brake system should discharge lots of heat energy while braking. A ventilated type brake disc has been used to increase heat discharge performance of a brake system. The vent structure of a disc highly affects cooling efficiency. This paper compares thermal characteristics of three types of vent structure in JASO C421 braking condition. It is found that the slant bend type disc has the lowest temperature and thermal stress distributions in the braking condition.

A Case Study of Root Cause Analyses and Remedies for High frequency Vibration of Globe Valve in Nuclear Power Plant Piping System (원자력 발전소 배관계 글로브 밸브의 고주파 진동 원인 분석 및 해결 사례)

  • Choi, Byoung-Hwa;Park, Soo-Il;Cheon, Chang-Bin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.394-399
    • /
    • 2005
  • A case history is presented pertaining to high frequency piping vibration and noise caused by globe valve in the spent fuel pool cooling system of nuclear power plant. Frequency analyses were performed on the system to diagnose the problem and develop a solution to reduce the piping vibration and noise. The source of the high frequency and noise energy was traced to the globe valve located immediately downstream of the centrifugal pump by performing valve throttling test. Measurements of vibration and noise are presented to show that the high frequency vibration and noise amplitude was dependent upon the valve disc position and flow rate. Strouhal vortex shedding frequencies were generated at the exit of the globe valve which exited structural resonance of valve disc and amplified the high frequency vibration and noise. The problem was identified as an interaction between the flow inside globe valve and the valve disc structure. Attempts to reduce the vibration and noise amplitudes of the piping system were successfully achieved by the modification of guide-disc diameter and disc-edge figure The valve disc was replaced by an alternative to eliminate the source of the harmful high frequency vibration and noise.

  • PDF

Disparity between MR Imaging and Histochemical Grading in Human Intervertebral Disc Degeneration

  • Lee, June-Ho;Chung, Chun-Kee;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.432-437
    • /
    • 2006
  • Objective : In order to establish the index of degeneration, the authors performed a histochemical study with Safranin-O staining and investigated the occurrence of apoptosis in the human intervertebral disc. Methods : Eighteen intervertebral disc specimens surgically extracted from the patients and two additional specimens from the autopsied cases were stained with Safranin-O for proteoglycan according to a standard protocol. Terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate- biotin nick end labeling[TUNEL] was used to detect the fragmented DNA known to be associated with apoptotic cell death and classification scheme was formulated for categorization of the degree of Safranin-O staining [normal, moderate reduction, faint] by modification of Makin's histological-histochemical grading. The Kruskal-Wallis H test and Chi-square test were used for statistical analysis. Results : The statistical results showed a significant difference in the mean age between "normal" Safranin-O staining group and the others [19.3 versus 55, 43.4, p=0021]. However, there was no statistically significant correlation between Safranin-O staining and MR grading of disc degeneration. Only six of eighteen surgical specimens and none in autopsies showed positive apoptotic cells in TUNEL staining. Conclusion : The determination of the degree of degeneration in surgically obtained disc tissue per se by histochemical staining or by the degree of apoptosis that corresponds to its morphologic change was not feasible.

Smart Flying-Disc Monitoring System with IoT Technology (IoT 기술이 적용된 스마트 플라잉 디스크 모니터링 시스템 구축)

  • Lee, Jung-Chul;Jang, Young-Jong;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.991-1000
    • /
    • 2019
  • The flying-disc game has started since 1940. It has been spreading rapidly in Korea since 2007, mainly in elementary schools. Additionally, as sports science has been developed, research on flying discs has been continued to build a monitoring system for technological improvement and efficiency. In this paper, we acquire information on the user's flying-disc using 9-axis motion sensor and GPS. Then we propose a method for wireless transmission using Bluetooth 5.0. Specifically, the HW platform was designed and implemented not only to monitor a real-time data but also to compare and analyze rotational speed, flight trajectory, and a count of disc rotation through post-processing.

Technology Trend of Hypergolic Igniter and Rupture Disc (자연발화 점화기 및 파열판 기술 동향)

  • Yoo, Jae-Han;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.213-218
    • /
    • 2012
  • Survey on the hypergolic igniter and rupture disc for liquid rocket engines was performed. The patent of the igniter for US MC-1 and Russia RD-170 Engine and the disc for NASA's space vehicle were analyzed. The types, characteristics, performances, design parameters and ASME standards of the disc are examined. The performances have manufacturing tolerance, reverse pressure, flow disturbance, fragmentation, material, working fluid and operating ratio. Also, survey on structural analyses of the rupture disc were performed.

  • PDF