• 제목/요약/키워드: Disc

검색결과 3,934건 처리시간 0.033초

악관절원판의 전방변위에 따른 관절간극의 변화 (CHANCE OF JOINT SPACE ACCORDING TO ANTERIOR DISC DISPLACEMENT OF TMJ)

  • 배정수;김준배;김형순
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.410-416
    • /
    • 2001
  • Objective: Disc displacement may affect the joint space narrowing between condylar head and glenoid fossa. This study was designed to evaluate the correlation between the joint space change and the severity of anterior disc displacement. Materials and Methods: Two hundreds temporomandibular joints MR images of TMD patients(170 joints) and asymptomatic volunteers(30 joints) were evaluated for this purpose. Anterior disc displacement was divided into 3 stages(normal, little to mild, and moderate to severe displacement) based on sagittal images, then joint spaces were measured at medial, central and lateral parts of condyle head on coronal MR images, respectively The joint spaces of 3 groups divided according to the severity of anterior disc displacement were compared. Results: The reduction of joint space was related to the severity of the anterior disc displacement at lateral, medial side and especially at center Conclusion: The temporomandibular joint space was affected by the severity of the anterior disc displacement.

  • PDF

경막내 요추 추간반 탈출증 - 증례보고 - (Intradural Lumbar Disc Rupture - Case Report -)

  • 정주호;이상구;유찬종;한기수;김우경;김영보;박철완;이언
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1233-1236
    • /
    • 2001
  • The intradural lumbar disc herniation which was first described by Dandy in 1942 is unusual. The pathogenesis is obscure and preoperative diagnosis is not easy. The patient usually have more severe neurologic deficits than those found in the much more common extradural disc herniations. We experienced two cases of the intradural lumbar disc herniation who had previous disc operations and the symptoms and neurologic signs were improved after removal of the intradural sequestration of disc fragments.

  • PDF

Colombini 방법에 의한 요추부 추간판 크기 추정에 관한 연구 (A Study of Estimation of Lumbar Intervertebral Disc Size by Colombini's Method)

  • 김종순
    • The Journal of Korean Physical Therapy
    • /
    • 제19권1호
    • /
    • pp.23-31
    • /
    • 2007
  • Purpose: As a preliminary study, the purpose of this study was to examine the indirect estimation of the lumbar intervertebral disc size by two anthropometric methods, in order to compare these indirect methods with the direct analysis by radiological imaging. Methods: The wrist, elbow, knee, and ankle joint (both right and left) diameters were measured in 52 volunteers, and then intervertebral disc size was calculated using two anthropometric methods (Colombini and modified Colombini). The data were analysed with independent t-test to assess clinical usefulness. Results: When using right and left joint diameter, there was no significant difference in the estimation value of the L4-5 and L5-S1 intervetebral disc sizes. However, the study has shown that male subjects have significantly larger L4-5 and L5-S1 intervertebral disc sizes, compared with those of female subjects. In addition, disc sizes calculated by Colombini's formula were significantly larger than modified Colombini's formula. Conclusion: The indirect estimation of the intervertebral disc size by anthropometric method can be considered as a clinically useful method. However, further study should be conducted to compare anthropometric values with other radiological imaging.

  • PDF

블루레이 디스크의 커버레이어 스핀 코팅 시 다양한 패턴에 따른 최적화된 폴리머 거동에 관한 연구 (Flow Behavior of Thin Polymer Film by various patterns in Spinning Coating Process of Blu-ray Disc Cover layer)

  • 조기철;박유하;김헌영;김병희;이해곤;손성기;신홍규
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.467-471
    • /
    • 2005
  • In this paper, experimental methods about the flow behavior of thin polymer film by various edge patterns in the spin coating process for stable cover layer coating of a blu-ray disc is described. The blu-ray disc, a next-generation optical disc format over 25GB, consists of a 1.1m thick substrate and a 0.1mm tick cover layer. Generally, cover layer on the blu-ray disc is made by the polymer spin coating process. However, it is hard to secure sufficient coating uniformity around the rim on the cover layer. In order to get the uniform thickness deviation and to minimize the bead around the rim, the edge of the disc substrate can be modified into various patterns, such as normal plain, trench, step and chamfer pattern, etc, around the rim on the disc and experimented with various parameters, such as surface tension, viscosity, coating time, temperature and rotation speed, etc. And the optimal shape of the rim was tried to get by 3 dimensional computer simulation of the polymer expulsion process.

  • PDF

Super-RENS Disc의 Random 신호 특성 (Random Signal Characteristics of Super-RENS Disc)

  • 배재철;김주호;김현기;황인오;박창민;박현수;정문일;노명도
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.119-123
    • /
    • 2005
  • We report the random pattern characteristics of the super resolution near field structure(Super-RENS) write once read-many(WORM) disc at a blue laser optical system(laser wavelength 405nm, numerical aperture 0.85) and the Super-RENS read only memory(ROM) disc at a blue laser optical system(laser wavelength 659nm, numerical aperture 0.65). We used the WORM disc of which carrier-to-noise ratio (CNR) of 75nm is 47dB and ROM disc of which carrier-to-noise ratio (CNR) of 173nm is 45dB. We controlled the equalization (EQ) characteristics and used advanced partial-response maximum likelihood (PRML) technique. We obtained bit error rate (bER) of 10-3 level at 50GB WORM disc and bite error rate of 10-4 level at 50GB level ROM disc. This result shows high feasibility of Super-RENS technology for practical use.

  • PDF

MRI상 격리된 디스크(Sequestrated disc) 소견을 보인 환자를 대상으로 시행한 한방 보존적 치료 호전 치험 4례 (The Clinical Report on 4 Cases of Sequestrated Disc Patients Treated by Conservative Oriental Medical Treatment)

  • 민관식;이진혁;김수영;한창우
    • 척추신경추나의학회지
    • /
    • 제5권1호
    • /
    • pp.67-80
    • /
    • 2010
  • Objectives : This study is to investigate the clinical application of conservative oriental medical treatment to a patient who were diagnosed as 'Sequestrated disc' on MRI. Methods: We evaluated 5 patients. who were diagnosed as 'Sequestrated disc' on MRI. after conservative oriental medical treatment by Numeric Rating Scale(NRS), Straight Leg Rasing Test(SLRT) and MRI follow-up. Result: 5 patients showed significant improvement in Numeric Rating Scale(NRS). Straight Leg Rasing Test(SLRT) after conservative oriental medical treatment. Also their sequestrated disc were significantly dissapeared or decreased in volume on MRI after the treatment. Conclusion: Conservative oriental medical treatment can be effective for improving pain and volume of herniated disc for patients with sequestrated disc.

  • PDF

알루미늄 디스크 브레이크의 성능 실험 및 해석에 관한 연구 (Study on Performance Experiment and Analysis of Aluminum Disc Brake)

  • 류미라;이대희;이성범;박정호;심재준
    • 한국기계가공학회지
    • /
    • 제12권6호
    • /
    • pp.60-68
    • /
    • 2013
  • The present research aims to develop aluminum disc brakes to replace existing cast iron disc brakes in automobiles. The foundation for developing an aluminum disc is laid by investigating the performance characteristics of existing cast iron disc brakes and comparing those characteristics with those of aluminum disc brakes. This study involves FEM thermal/structural analysis of disc materials and experimental tests using a brake dynamometer. The results of this study show that, aluminum discs have not only better thermal/mechanical properties than existing cast iron discs, including better heat, wear, and crack resistance, but also that aluminum discs. Weigh less than existing cast iron discs, which results in improved maneuverability. Aluminum discs will become a more essential part of automobiles as electric cars become the major means of transportation.

블루레이 디스크의 커버레이어 스핀코팅 시 폴리머 거동에 관한 연구 (Flow Behavior of Thin Polymer Film in Spinning Coating Process of Blu-ray Disc Cover layer)

  • 반준호;신홍규;김병희;김헌영;이해곤;손성기;신재구
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 2005
  • In this paper, a computational and experimental analysis about the flow behavior of thin polymer film in the spin coating process for stable cover layer coating of a blu-ray disc is described. The blu-ray disc, a next-generation optical disc format over 25GB, consists of a 1.1mm thick substrate and a 0.1mm tick cover layer. Generally, cover layer on the blu-ray disc is made by the polymer spin coating process. However, it is hard to secure sufficient coating uniformity around the rim on the cover layer. In order to get the uniform thickness deviation and to minimize the bead around the rim, the edge of the disc substrate can be modified into various shapes around the rim on the disc and analyzed with various parameters, such as surface tension, viscosity, and rotation speed, etc. The optimal shape of the rim was tried to get by 3 dimensional computer simulation of the polymer expulsion process.

  • PDF

Super-RENS Disc의 Random 신호 특성 (Random Signal Characteristics of Super-RENS Disc)

  • 배재철;김주호;김현기;황인오;박창민;박현수;정문일;노명도
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.38-42
    • /
    • 2006
  • We report the random pattern characteristics of the super resolution near field structure(Super-RENS) write once read-many(WORM) disc at a blue laser optical system(laser wavelength 405nm, numerical aperture 0.85) and the Super-RENS read only memory(ROM) disc at a blue laser optical system(laser wavelength 659nm, numerical aperture 0.65). We used the WORM disc of which carrier-to-noise ratio(CNR) of 75nm is 47dB and ROM disc of which carrier-to-noise ratio(CNR) of 173nm is 45dB. We controlled the equalization(EQ) characteristics and used advanced partial-response maximum likelihood(PRML) technique. We obtained bit error rate(bER) of 10-3 level at 50GB WORM disc and bite error rate of 10-4 level at 50GB level ROM disc. This result shows high feasibility of Super-RENS technology for practical use.

  • PDF

Extent of Disc Degeneration after Single-Level Cervical Anterior Microforaminotomy Analyzed with Long-Term Radiological Data

  • Han, Chul;Kim, Myung-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권3호
    • /
    • pp.200-205
    • /
    • 2014
  • Objective : To prove the extents and details of cervical degeneration after anterior microforaminotomy (AMF) with 6-years follow-up. Methods : A retrospective study of 24 patients, underwent single-level AMF, was performed. Clinical and radiologic data were analyzed with office charts, questionaires, and picture achieving and communication system images. Results : According to Odom's criteria, 91.6% achieved favorable outcome. The mean visual analog scale score was improved from 8.6 to 3, and the mean neck disability index was improved from 27.9 to 7.3 (p<0.01). Eighteen cases (75%) showed disc height (DH) decrease. The disc invasion was correlated with DH decrease (p<0.05). The disc height decrease correlated with static, dynamic changes of shell angle and spur formation (p<0.05). Any radiological parameters did not affect the clinical outcome. Conclusion : AMF is an effective technique for treating unilateral cervical radiculopathy. It showed excellent surgical outcomes even in long-term follow-ups. However, a decrease in DH occurred in a considerable number of patients. Disc invasion during surgery may be the trigger of sequential degeneration.