• Title/Summary/Keyword: Direct solar

Search Result 414, Processing Time 0.021 seconds

Photoelectrochemical cells based on oxide semiconductors

  • Yun, Yeong-Dae;Baek, Seung-Gi;Kim, Ju-Seong;Kim, Yeong-Bin;Jo, Hyeong-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.50.2-50.2
    • /
    • 2018
  • The demand for steady and dependable power sources is very high in the field of sustainable energy because of the limited amount of fossil fuels reserves. Among several sustainable alternatives, solar energy may be the most efficient solution because it constitutes the largest renewable energy source. So far, the only practical way to store such large amounts of energy has been to use a chemical energy carrier likewise a fuel. In various solar energy to power conversion systems, the photoelectrochemical (PEC) splitting of water into hydrogen and oxygen by the direct use of solar energy is an ideal process. It is a renewable method of hydrogen production integrated with solar energy absorption and water electrolysis using a single photoelectrode. Previous studies on photoelectrode films for PEC water splitting cells have been mainly focused on synthesizing oxide semiconductors with wide band gaps, such as TiO2(3.2eV), WO3(2.8eV), and Fe2O3(2.3eV). Unfortunately, these pristine oxide photoanodes without any catalysts have relatively low photocurrent densities because of the inherent limitation of insufficient visible light absorption due to the wide bandgap. Specifically, there is a tradeoff between high photocurrent and photoelectrochemical corrosion behavior, which is representative of figures of meritf or PEC materials.

  • PDF

A Study on the State of the Art and the Future Utilization Prospect of Natural Energy Resources (자연(自然)에너지 자원(資源)의 유효이용(有效利用)과 개발수준(開發水準)에 관한 연구(硏究))

  • Chung, K.S.;Yoo, S.H.
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.15-37
    • /
    • 1996
  • Most of the world's energy demand is met by fossil fuels, mainly petroleum and natural gas. Even though their production is not keeping up with the demand, there are many options before us-solar energy in its direct and indirect forms, nuclear breeders, thermonuclear power, geothermal energy, synthetic fluid fuels, and hydrogen as energy carrier to complement the nonfossil energy sources. But, before these energy alternatives can be utilized, in most cases, it is necessary to conduct extensive research and development work. In order to solve global energy and environmental issues, it is very important to develop and install energy supply systems which utilizes natural energy. The installation of these systems brings the following merits from the viewpoints of energy saving or environmental protection-(a) the positive use of natural energy reduces fossil fuel consumption; and (b) it also prevents environmental degradation. In this paper, the types of natural energy considered is confined to the solar, wind, hydraulic, geothermal and ocean-wave energy. And, the objective of the paper is to describe the state of the art of natural energy and future utilization prospect of them.

  • PDF

Optimization of three small-scale solar membrane distillation desalination systems

  • Chang, Hsuan;Hung, Chen-Yu;Chang, Cheng-Liang;Cheng, Tung-Wen;Ho, Chii-Dong
    • Membrane and Water Treatment
    • /
    • v.6 no.6
    • /
    • pp.451-476
    • /
    • 2015
  • Membrane distillation (MD), which can utilize low-grade thermal energy, has been extensively studied for desalination. By incorporating solar thermal energy, the solar membrane distillation desalination system (SMDDS) is a potential technology for resolving the energy and water resource problems. Small-scale SMDDS (s-SMDDS) is an attractive and viable option for the production of fresh water for small communities in remote arid areas. The minimum-cost design and operation of s-SMDDS are determined by a systematic method, which involves a pseudo steady state approach for equipment sizing and the dynamic optimization using overall system mathematical models. The s-SMDDS employing three MD configurations, including the air gap (AGMD), direct contact (DCMD) and vacuum (VMD) types, are optimized. The membrane area of each system is $11.5m^2$. The AGMD system operated for 500 kg/day water production rate gives the lowest unit cost of $5.92/m^3$. The performance ratio and recovery ratio are 0.85 and 4.07%, respectively. For the commercial membrane employed in this study, the increase of membrane mass transfer coefficient up to two times is beneficial for cost reduction and the reduction of membrane heat transfer coefficient only affects the cost of the DCMD system.

Non-grey Radiative Transfer in the Solar Surface Convection

  • Bach, Kie-Hunn;Kim, Yong-Cheol
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.34.1-34.1
    • /
    • 2011
  • Combining a detailed non-grey radiative transfer computation with the three dimensional hydrodynamics, we investigate a reliable numerical scheme for turbulent convection in the solar surface. The solar photosphere is the extremely turbulent region composed of partly ionized compressible gases in high temperature. Especially, the super adiabatic layer (SAL) near the solar photosphere is the shallow transition region where the energy transport varies steeply from convection to radiation. In order to describe physical processes accurately, a detailed treatment of radiative transfer should be considered as well as the high resolution computation of fluid dynamics. For a direct computation of radiation fields, the Accelerated Lambda Iteration (ALI) methods have been applied to hydrodynamical medium, incorporating the Opacity Distribution Function (ODF) as a realistic schemes for non-grey problems. Computational domain is the rectangular box of dimensions $42{\times}3Mn$ with the resolution of $1202{\times}190$ meshed grids, which covers several granules horizontally and 8 ~ 9 pressure scale heights vertically. During several convective turn-over times, the 3-D snapshots have been compiled with a second order accuracy. In addition, our radiation-hydrodynamical computation has been compared with the classical approximations such as grey atmospheres and Eddington approximation.

  • PDF

TEMPORAL CHANGE OF MAGNETIC SHEAR FREE FROM THE 180° AMBIGUITY

  • MOON Y.-J.;WANG HAIMIN;SPIROCK THOMAS J.;PARK Y. D.
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.3
    • /
    • pp.143-149
    • /
    • 2002
  • In this paper we present a methodology to derive the temporal change of the magnetic shear angle from a series of vector magnetograms, with a high time cadence. This method looks for the minimum change of the shear angle between a pair of magnetograms, free from the $180^{\circ}$ ambiguity, and then accumulates this change over many successive pairs to derive the temporal change of magnetic shear. This methodology will work well if only the successive magnetograms occurred in an active region are well aligned and its helicity sign is reasonably determined. We have applied this methodology to a set of vector magnetograms of NOAA Active Region 9661 on October 19, 2001 by the new digital magnetograph at the Big Bear Solar Observatory (BBSO). For this work we considered well aligned magnetograms whose cross-correlation values are larger than 0.95. As a result, we have confirmed the recent report of Wang et al. that there was the abrupt shear change associated with the X1.6 flare. It is also demonstrated that the shear change map can be an useful tool to highlight the local areas that experienced the abrupt shear change. Finally, we suggest that this observation should be a direct support of the emergence of sheared magnetic fields.

An Analysis of Observational Environments for Solar Radiation Stations of Korea Meteorological Administration using the Digital Elevation Model and Solar Radiation Model (수치표고모델과 태양복사모델을 이용한 기상청 일사 관측소 관측환경 분석)

  • Jee, Joon-Bum;Zo, Il-Sung;Kim, Bu-Yo;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.40 no.2
    • /
    • pp.119-134
    • /
    • 2019
  • In order to analyze the observational environment of solar radiation stations operated by the Korea Meteorological Administration (KMA), we used the digital elevation model (DEM) and the solar radiation model to calculate a topographical shading, sky view factor (SVF) and solar radiation by surrounding terrain. The sky line and SVF were calculated using high resolution DEM around 25 km of the solar stations. We analyzed the topographic effect by analyzing overlapped solar map with sky line. Particularly, Incheon station has low SVF whereas Cheongsong and Chupungryong station have high SVF. In order to validation the contribution of topographic effect, the solar radiation calculated using GWNU solar radiation model according to the sky line and SVF under the same meteorological conditions. As a result, direct, diffuse and global solar radiation were decreased by 12.0, 5.6, and 4.7% compared to plane surface on Cheongsong station. The 6 stations were decreased amount of mean daily solar radiation to the annual solar radiation. Among 42 stations, eight stations were analyzed as the urgent transfer stations or moving equipment quickly and more than half of stations (24) were required to review the observational environment. Since the DEM data do not include artifacts and vegetation around the station, the stations need a detail survey of observational environment.

Experimental Study on Inward Melting of Phase Change Material in Inclined Circular Tube (경사진 원통형 용기내에서 상변화 물질의 내향 용융에 관한 실험적 연구)

  • Yim, Chang-Soon;Son, Ha-Jin
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.48-58
    • /
    • 1992
  • In the present investigation, experimental analysis was performed to research heat transfer phenomena generated by means of conduction and natural convection at a succession of tube-inclimations relative to the vertical tube during inward melting process of a phase change material. The phase change material used in the experiments is 99 percent pure n-docosane paraffin($C_{22}H_{46}$). When the tube is vertical, the dominant mode of energy transfer between the tube wall and the melting interface is natural convection. On the other hand, when the tube is inclined to the vertical, the melting solid is brought into direct contact with the tube wall by the action of gravity. In the experimental results, direct contact gave rise to substantial enhancements in the amount of melted mass, relative to those for natural-convection-dominated melting.

  • PDF

Image Capturing of Dispersed Phases in DCHXs by Electric Tomography

  • Chun, Won-Gee;Kim, Min-Chan;Lee, Heon-Ju;Kang, Yong-Heack;Kwon, Hyok-Bo
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.69-78
    • /
    • 2001
  • This paper introduces the physical phenomena involved in Direct Contact Heat Exchangers (DCHXs) and also investigates the possibility of applying of EIT(Electrical Impedance Tomography) technique for capturing the images of dispersed phases as they stream through a stagnant body of water. A number of cases are studied where two dimensional cross-sectional static images are given for fictitious and actual masses present in a column of water(saline solution). In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density different(lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the elucidation of complicated flow field where the dispersed phase fluid tends to change its shape and size constantly during its journey through the other phase(water). This paper presents a number of results with different types of dispersed phases that are immiscible with water. The EIT technique has been employed in this context to test its applicability in capturing the dynamic images of dispersed phases. It shows static images of dispersed phases where dynamic images could be obtained by simply extending the algorithms and strategies employed in the present analysis.

  • PDF

Tracking System of Photovoltaic Generation Using DFC Controller (DFC 제어기를 이용한 태양광 발전의 추적시스템)

  • Jung, Byung-Jin;Choi, Jung-Sik;Ko, Jae-Sub;Kim, Do-Yeon;Jung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.199-201
    • /
    • 2008
  • In this paper proposed the solar tracking system to use direct fuzzy control order to increase an output of the PV (Photovoltaic) array. The solar tracking system operated two DC motors driving by signal of photo sensor. The control of dual axes is not an easy task due to nonlinear dynamics and unavailability of the parameters. Recently, artificial intelligent control of the fuzzy control, neural-network and genetic algorithm etc. have been studied. The fuzzy control made a nonlinear dynamics to well perform and had a robust and highly efficient characteristic about a parameter variable as well as a nonlinear characteristic. Hence the fuzzy control was used to perform the tracking system after comparing with error values of setting-up, nonlinear altitude and azimuth. In this paper designed a DFC(Direct Fuzzy Control)controller for improving output of PV array and evaluated comparison with efficient of conventional PI controller. The data which were obtained by experiment were able to show a validity of the proposed controller.

  • PDF

The Comparison of Operating Characteristics of SVC and STATCOM for Compensating the Reactive Power in the Jeju Power System (제주계통의 무효전력보상을 위한 SVC와 STATCOM의 운전특성 비교)

  • LEE, SEUNGMIN;Kim, Eel-Hwan;Kim, Ho Min;Oh, Sung-Bo;LEE, DOHEON
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.49-56
    • /
    • 2015
  • This paper presents a comparative operating characteristics of static var compensator(SVC) and static synchronous compensator(STATCOM) for compensating the reactive power in the Jeju power system. There are two kinds of reactive power compensating systems, which are active and passive system in the applications of the line commutated converter type high voltage direct current (LCC-HVDC). In the Jeju power system, two STATCOMs as active compensating system have been operating. Even though STATCOM has good performance compared with SVC, economical efficiency of former system is not good to the latter system. So, it is necessary to examine the performance and economical efficiency depend on the intention before appling the system. To compare the operating characteristics of two systems in the Jeju power system, simulations have been carried out for case studies that both of the HVDC system have transient state by using PSCAD/EMTDC program.