• Title/Summary/Keyword: Direct response

Search Result 1,594, Processing Time 0.024 seconds

Human Response Capability and Customer Relationship Management Advantage: The Direct, Indirect, and Interactive Roles of Information Technology Service Application

  • Yang, Yi-Feng;Chen, Ching-Yaw;Lee, Yu-Je;Lee, Shyh-Hwang
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.2 no.3
    • /
    • pp.33-42
    • /
    • 2014
  • The main purpose of this study intends to study the theoretical interconnection between human response capability and customer relationship management advantage while considering the essential role of service application of information technology as direct, indirect (mediating), and interactive (moderating) influences in the theory. Based on the study sample, the new findings help comprehend the overall interconnected relationship which includes the direct and indirect (mediating) effects of information technology service capability and human response capability as well as their interaction (moderation) on customer relationship management advantage. The new insights interprets the two capabilities (human and information technology) are vital to business because they are the foundation set of service resources significantly to enhance customer relationship management advantage.

Evaluation of patient transportation and response intervals among emergency medical squads (구급대 환자이송과 반응시간의 평가)

  • Park, Sang-Kyu;Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.3
    • /
    • pp.47-54
    • /
    • 2018
  • Purpose: The purpose of this study was to present evidence for quality management based on analysis of patient transportation and response intervals among emergency medical squads. Methods: The chi-square test was used to determine whether mental status and patient assessment affected direct medical control and hospital destination. One way analysis of variance was used to compare response intervals depending on mental status and patient assessment using data drawn from 1172 prehospital care reports. Results: There was a statistically significant relationship between mental status and direct medical control (p<.001); there was a statistically significant relationship between patient assessment and hospital destination (p=.011). However, there was no statistically significant relationship between mental status and hospital destination. The interval from arrival at the patient's side to departure from the scene showed a statistically significant difference (p<.001, p<.001), however, it took the longest time (16.8 minutes) in unresponsive patients. It showed a statistically significant difference (p<.001) in the interval from arrival at patient's side to departure from the scene depending on patient assessment; however, it took the longest time (9.6 minutes) in emergency patients. Conclusion: There was call for direct medical control based on patient assessment; however, patient transportation and response intervals were not appropriate.

The Nonlinear Direct Spectrum Method Improving Application and Reliability of Existing Approximate Nonlinear Methods (기존 비선형약산법들의 신뢰성 개선을 위한 비선형직접스펙트럼법)

  • Kim, Jae-Ung;Kang, Pyeong-Doo;Jun, Dae-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.4 s.50
    • /
    • pp.55-66
    • /
    • 2006
  • This paper considers the nonlinear direct spectrum method to estimate seismic performance of mixed building structures without iterative computations, given dynamic property $T_1$ from stiffness skeleton curve and nonlinear pseudo acceleration $A_{1y}/g$ and/or ductility ratio p from response spectrum. Nonlinear response history analysis has been performed and analysed with various earthquakes for evaluation of correctness and confidence of nonlinear direct spectrum method. The conclusions of this study are as follows; (1) Nonlinear direct spectrum method is considered as a practical method which is applicable to compute the structural initial elastic period and the yielding strength from stiffness skeleton owe and calculate the nonlinear maximum response of structure directly from nonlinear response spectrum. (2) The comparison of the analysis results from NDSM and NRHA showed that the average errors were less than 20% in about 3/4 of the analysis cases, and that the results obtained from NDSM turned out to be generally larger than those from NRHA.

Direct Torque Control of Squirrel Cage Typed Induction Motor Using Fuzzy Controller (퍼지제어기를 이용한 농형 유도 전동기의 직접 토크제어)

  • Han, Sang-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.122-129
    • /
    • 2008
  • The direct torque control method of an inverter fed squirrel cage typed induction motor using fuzzy logic controller has been proposed. This method is suitable for the traction which requires a fast torque response during the star-up and step change. The fuzzy control algorithm based upon the control principles of conventional DSC(Direct Self Controller) is developed. The fuzzy algorithm is tarried out by defuzzification strategy of the fuzzy output extracted from the possibility distribution of an inferred fuzzy control rule. The flux and torque of an induction motor are estimated by the dynamic model of the rotor flux field-oriented scheme which has decoupling characteristics and excellent dynamic response over a wide speed range. The proposed controller shows a good dynamic response. Moreover, since the fuzzy controller possesses highly adaptive capability, the performance of fuzzy controller is quite robust and insensitive to the motor parameters and change of operation conditions.

A Hydraulic-Oil Pump System using SR Drive with a Direct Torque Control Scheme

  • Lee, Dong-Hee;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.491-498
    • /
    • 2009
  • The hydraulic-oil pump is widely used for building machinery, brake systems of vehicles and automatic control systems due to its high dynamic force and smooth linear force control performance. This paper presents a novel direct instantaneous pressure control of the hydraulic pump system with SRM drive. The proposed hydraulic pump system embeds the pressure controller and direct instantaneous torque controller. Due to the proportional relationship between pump pressure and torque, pressure can be controlled by the motor torque directly. The proposed direct torque controller can reduce inherent torque ripple of SRM, and develop a smooth torque, which can increase the stability of the hydraulic pump. The proposed hydraulic pump system has also fast step response and load response. The proposed hydraulic pump system is verified by computer simulation and experimental results.

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

A Study on the Speed and Torque Control of Propulsion Motor for Electric Propulsion Ship by Direct Torque Control (직접토크제어에 의한 전기추진선박의 추진전동기 속도 및 토크제어에 관한 연구)

  • Kim, Jong-Su;Oh, Sae-Gin;Kim, Seung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.946-951
    • /
    • 2009
  • An induction motor based on DTC(Direct Torque Control) is being increasingly used in various industrial applications. DTC offers faster torque response and better speed control with lesser hardware and processing costs in compared with other controlled drives. This study was to evaluate performance of DTC for induction motor of electric propulsion ship. The simulation results indicated good speed and torque response from the low to middle speed range. Also, DTC has advantages such as the independency on motor parameter.

The Hypersensitive Response. A Cell Death during Disease Resistance

  • Park, Jeong-Mee
    • The Plant Pathology Journal
    • /
    • v.21 no.2
    • /
    • pp.99-101
    • /
    • 2005
  • Host cell death occurs during many, but not all, interactions between plants and the pathogens that infect them. This cell death can be associated with disease resistance or susceptibility, depending on the nature of the pathogen. The most well-known cell death response in plants is the hypersensitive response (HR) associated with a resistance response. HR is commonly regulated by direct or indirect interactions between avirulence proteins from pathogen and resistance proteins from plant and it can be the result of multiple signaling pathways. Ion fluxes and the generation of reactive oxygen species commonly precede cell death, but a direct involvement of the latter seems to vary with the plant-pathogen combination. Exciting advances have been made in the identification of cellular protective components and cell death suppressors that might operate in HR. In this review, recent progress in the mechanisms by which plant programmed cell death (PCD) occurs during disease resistance will be discussed.

Comparative Study on the Application of Direct Analysis Method to Large Container Carriers (대형 컨테이너선의 직접해석법에 관한 비교 연구)

  • Ryu Hong-Ryeul;Lee Joo-Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.4 s.148
    • /
    • pp.484-493
    • /
    • 2006
  • Recently, direct load analysis using ship motion program is required to confirm structural safety for the Post-Panamax class large container carrier. However, there is no exact comparative study data for structural response between 20 and 30 wave load. So, in this paper, to compare the hull girder stress response between 20 versus 3D wave load calculation method, direct load analysis and global F.E analysis have been performed for three kinds of large container vessels using each 20 and 30 wave load calculation program. The results of 2D wave load RAO(Response Amplitude Operator) of each dominant load parameter(vertical, torsional and horizontal moment) are generally bigger than that of 30 results, especially in vertical wave bending moment. And the results of structural analysis based on the equivalent design wave method shows that there is a big difference in view of stress, but the stress distribution is very similar for each wave load case.

Robust Time Delay Compensation for DTC-Based Induction Machine Systems via Extended State Observers

  • Wang, Fengxiang;Wang, Junxiao;Yu, Li
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.736-745
    • /
    • 2018
  • This paper presents an extended state observer (ESO) based direct torque control (DTC) for use in induction motor systems to handle the issues of time delays, load torque disturbances and parameter uncertainties. Direct torque control offers an excellent torque response and it does not require a proportion integration (PI) controller in the current loop. However, a PI controller is still adopted in the outer speed loop to generate the torque reference value, which is a slow method. An ESO based compound control scheme is proposed to improve the response rate and accuracy of the torque reference signal, especially when load torque is injected. In addition, the time delay problem is analyzed and compensated for in this paper to reduce torque ripples. The proposed disturbance compensation technique based direct control scheme is shown to have good performance both in the transient and stable states via simulations and experimental results.