• Title/Summary/Keyword: Direct ophthalmoscope

Search Result 4, Processing Time 0.018 seconds

Investigation of Instrument for Photostress Recovery Time Test in the Eye (눈의 광피로회복시간 검사를 위한 도구의 탐색)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.193-196
    • /
    • 2013
  • Purpose: This study was investigated to find out a useful instrument instead of direct ophthalmoscope for ocular photostress recovery time (PSRT) test. Methods: The PSRT test was performed using direct ophthalmoscope, trans illuminator, pen light, and camera flash for 48 subjects (average age 22.88 years, 96 eyes) who were corrected to 0.8~1.2 of visual acuity. Results: Each mean of PSRT measured by direct ophthalmoscope, trans illuminator, pen light, and camera flash was $27.90{\pm}18.40$ sec, $23.73{\pm}12.99$ sec, $21.31{\pm}15.57$ sec, and $18.98{\pm}11.64$ sec, respectively. The difference of PSRT between the eyes corrected more than 1.0 and the other eyes corrected under 1.0 of visual acuity was not found significantly. And there was no difference between dominant eyes and nondominant eyes of PSRT. Conclusions: Though the nearest instrument to direct ophthalmoscope was trans illuminator, pen light and camera flash could be the useful instruments for PSRT test.

The Study on Hansen's Disease of Ametropia (나환자들의 비정시에 대한 고찰)

  • Lee, Hark Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.145-150
    • /
    • 1998
  • To 160 persons(90 men, 70 women) who went to the national hospital of Solok-island with Hansens's disease, I tested the objective refracts test with the product of Cannon Ltd. Co. which RK-3 Auto Ref-keratometer's auto ophthalmoscope. The results were like these. Visual acuity of above 0.7 that can live without glasses was contained 44 men's eyes(24.4%) and 19 women s eyes(13.6%). These result are indicated that men have had more good visual acuity than women. Visual acuity of below 0.6 that cannot do normal life was contained 80.3% of the total patients. And amblyopia of below 0.3 and eyes which cannot be corrected were shown 44.4%(80 men's eyes and 55.7% 78 woman's eyes). Myopia was contained 119 eyes(43), hyperopia was contained 139 eyes (50.4%) and emmetropia was 6.5%. Astigmatism was shown 136 men s eyes (86.6%) and 97 women's eyes(81.5%). These results are indicated what many people accompany with astigmatism. And these ratio had some high percentages men rather than women. Direct astigmatic was contained 37 eyes (11.6%), Indirect astigmatic 81 eyes(25.3%) and Oblique Astigmatic 115 eyes(35.9%). As a of distributed result oblique astigmatic occupied best high point as 49.4% in 233 astigmatism and distributed the opposite direction as compared with normal irregular emmetropia not patient.

  • PDF

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Ophthalmic Findings in 547 Korean Sapsaree Dogs

  • Chae, Je-Min;Kim, Won-Tae;Jeong, Man-Bok;Yi, Na-Young;Park, Shin-Ae;Kim, Se-Eun;Park, Young-Woo;Ha, Ji-Hong;Han, Koog-Il;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.482-487
    • /
    • 2008
  • This study was performed to investigate the ophthalmic findings of the Korean traditional 'Sapsaree' dogs, and to provide ophthalmic references. Five hundred forty-seven Sapsaree dogs were randomly chosen without any criteria preference. Ophthalmic examination was performed bilaterally using ocular equipments, including slit-lamp biomicroscope, tonometer, direct and indirect ophthalmoscope. The obtained data for ophthalmic findings were analysis by the multivariate linear regression model to identify effects of sex, age and hair coat type. For congenital conditions, the incidence of persistent pupillary membrane (PPM) was the most common defect and there was present 8.8 % whereas for acquired ophthalmic diseases, cataract was the most commonly observed (3.7 %) in Sapsaree dog. Other frequent ocular finding included persistent hyaloid vessel remnant (PHVR, 6.2 %) in congenital conditions, and postinflammatory retinal degeneration (PIRD, 3.1 %) and corneal dystrophy (2.4 %) in acquired ophthalmic diseases. Only one significant effect was age of the Sapsaree for PIRD (P=0.040). There are no any significant effect for sex and hair coat types. This study will provide useful guidelines to clinicians and breeders for the basic ophthalmic information on this breed.