• Title/Summary/Keyword: Direct cooling

Search Result 309, Processing Time 0.023 seconds

Effects of Heat Treatment on Polyethylene Film for Power Cable Insulation(I) (전력 케이블용 폴리에틸렌의 열처리 효과(I))

  • Hong, Jin-Woong;Suzuoki, Yasuo;Mizutani, Teruyoshi
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1174-1176
    • /
    • 1993
  • Morphology of low density polyethylene(LDPE) such as the degree of crystallinity changes with thermal history etc. In order to clarify the effects of morphological changes on electrical breakdown, we studied direct current and impulse breakdown phenomena of LDPE films heat-treated at 100[$^{\circ}C$] for 1[H] in silicone oil and subsequently cooling to various ways. The degree of crystallinity was estimated by the infra red absorption and X-ray diffraction measurements for the specimens of slowly cooled, cooled in water, original, and cooled in liquid nitrogen gas. As the result, we obtained that the first, second, third, and fourth was slowly cooled of 70.23[%], cooled in water of 61.6[%], original specimen of 56.75[%], and cooled in liquid nitrogen gas of 34.7[%] respectively. The crystalline size and distribution of specimens were researched by Differential scanning calolimeter measurements.

  • PDF

Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System (아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 특성 분석)

  • Lee, Dong-Won;Lee, Soon-Myung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.111-115
    • /
    • 2006
  • To clarify the hydraulic and thermal characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flow in the double tube and plate type heat exchanger, experimental studies were performed. The mass flux and Ice fraction of ice slurry were varied from 800 to $3,500 kg/m^2s$(or 7 to 17 kg/min) and from 0 to 25%, respectively. During the experiment, it was found that the measured pressure drop and heat transfer rate increase with the mass flux and ice fraction; however the effect of ice fraction appears not to be significant at high mass flux region. At the region of low mass flux, a sharp increase in the pressure drop and heat transfer rate were observed depends on mass flux.

  • PDF

A Hydrodynamic Study of Stellar Wind Accretion in S-type Symbiotic Stars

  • Lee, Young-Min;Kim, Hyosun;Lee, Hee-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.72.1-72.1
    • /
    • 2019
  • Symbiotic stars are wide binary systems of a white dwarf and a mass losing giant, exhibiting various activities mainly attributed to accretion of a fraction of slow stellar wind emanating from the giant. We perform 3 dimensional hydrodynamical simulations using the FLASH code to investigate the formation and physical structures of an accretion disk in symbiotic stars with binary separation in the range of 2-4 au. Radiative cooling is introduced in the flow in order to avoid acute pressure increase in the vicinity of the accretor that may prevent stable disk formation. By setting the same density condition in front of the bow shock generated in two different velocity fields, the role of ram pressure balancing between the disk and the wind is examined. We find that three main streams (direct stream from the giant, stream following the accretion wake, and stream passing through the bow shock front) all feed the disk, and their individual contributions on the mass accretion onto the white dwarf are explored.

  • PDF

Modeling of vibration protection by shape memory alloy parts with an account of latent heat

  • Fedor S. Belyaev;Margarita E. Evard;Aleksandr E. Volkov;Maria S. Starodubova
    • Smart Structures and Systems
    • /
    • v.33 no.3
    • /
    • pp.243-251
    • /
    • 2024
  • Modeling of vibrations of a rotating pendulum with working shape memory alloy rod has been performed in the frames of a microstructural model taking into account the latent heat release, absorption and the heat exchange during direct and reverse martensitic transformation. It has been shown that the influence of the latent heat, the rate of preliminary deviation of the pendulum from the equilibrium, the rate of heating and cooling can have a significant impact on the vibrations and damping characteristics of the system.

The Effect of Grain Size and Cooling Rate on Phase Transformation for Mechanically Alloyed Ni-36at.%Al Alloy (기계적 합금화된 Ni-36at.%Al 합금의 상변태에 미치는 결정립 크기 및 냉각속도의 영향)

  • Kim, Seong-Uk;Kim, Dae-Geon;Kim, Ji-Sun;An, In-Seop;Kim, Yeong-Do
    • Korean Journal of Materials Research
    • /
    • v.10 no.9
    • /
    • pp.642-647
    • /
    • 2000
  • Nanocrystalline NiAl alloy containing 36at.%Al was synthesized by mechanical alloying (MA). Synthesized powder was sintered by a pulse electric current sintering (PECS) facility. Effecting parameters on the phase transformation were discussed in terms of cooling rate and time spent on heat treatment. The behavior of phase transformation for sintered parts was examined by differential scanning calorimetry (DSC) and X-ray diffraction (XRD) method. Microstructure was observed by scanning electron microscopy (SEM). Martensitic lattice parameter and volume fraction was calculated by direct comparison method in X-ray diffraction analysis.

  • PDF

Study on the PV Driven Dehumidifying System with Oyster Shell and Thermoelectric Device (굴패각과 열전소자를 이용한 태양광 구동형 제습시스템에 관한 연구)

  • Kim, Myoung-Jun;Chea, Gyu-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.3
    • /
    • pp.287-293
    • /
    • 2012
  • This paper has dealt with the probability of oyster shell desiccant cooling system driven by renewable energy of photo-voltaic effect. For this, fundamental experiments have been carried out focusing on the observation of dehumidifying effect of oyster shell and peltier elements used for air conditioning system. From this study, it is found that oyster shell has sufficient probability for using as a desiccant in air-conditioning system. Moreover, the heat releasing device(peltier element) can be used with direct current from PV cells so the system can be operated with high efficiency. As a result, the absolute humidity in a test chamber was reasonably controlled by oyster shell and peltier elements. Also the photo-voltaic energy from sun was enough for running power of this system.

The Freezing of Mouse Embryos (생쥐배의 동결보존)

  • 윤문석;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.8 no.2
    • /
    • pp.116-121
    • /
    • 1984
  • These experiments were carried out to examine the effect of rapid thawing (500$^{\circ}C$/min) on the survival of 8-cell mouse embryos cooled slowly (0.5-1$^{\circ}C$/min) to precooling temperatures between -10 and 070$^{\circ}C$ before direct transfer ofembryos to -196$^{\circ}C$, and to compare the survival of embroys thawed slowly (20$^{\circ}C$/min) and rapidly (500$^{\circ}C$/min) after in vitro culture. In addition, the sensitivity of 8-cell mouse embroys to the rate of addition and removal of cryoprotectant at room temperauture, and the effect of developing stages on the survival of embryos frozen-thawed slowly were investigated. The results obtained were summarized as follows: 1. Embryos were survived in rapid thawing (500$^{\circ}C$/min) only when slow cooling was terminated at relatively high subzero teperaure (-20 to -60$^{\circ}C$). The highest survival rate(77.0%) in in vitro culture of embryos thawed rapidly was obtaeined after transfer to -196$^{\circ}C$ from -40$^{\circ}C$. 2. For the survival of embryos in slow thawing (20$^{\circ}C$/min.), slow cooling to lower subzero temperature (-50$^{\circ}C$ and below) was required before transfer of embryos to -196$^{\circ}C$. These results indicate that embryos transferred to -196$^{\circ}C$ from high subzero temprature contain much interacellular ice to damage them during slow warming but to permit survival of embryos after rapid warming. 3. The Survival rate (72.7%) of 8-cell mouse embryos after rapid addition and removal of cryoprotectant, DMSO at room temperature was similar to that (83.9%) after slow addition and removal of cryoprotectant at same temperature. 4. The survival rates of 1-, 2-, 4- and 8-cell embryos frozen-thawed slowly were 26.7, 76.4, 70.0 and 83.9%, respectively.

  • PDF

Cryopreservation of Mouse 2-Cell Embryos (생쥐 2세포기배의 동결보존)

  • Baik, C.S.;Suh, B.H.;Lee, J.H.;Lee, K.K.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.1
    • /
    • pp.9-14
    • /
    • 1989
  • For the cryopreservation of human embryos this study was accomplished as a preliminary experiment. The purpose of this study is to obtain optimal cryoprotectant, addition and dilution method of cryoprotectant and cooling rate for raising survival of frozon and thawed 2-cell mouse embryos. Seeding was done at $-7^{\circ}C$ and the straw contained embryos was plunged at $-30^{\circ}C$ when the slow cooling was ended. Embryos those developed normally to blastocyst after in vitro culture for over 96 hours were regarded as survival ones. The survival was the rate of number of survival embryos against the recovered embryos. The results are followed : 1. The survivals were 6.3, 71.2 and 67.4% respectively, when Glycerol, DMSO and 1,2-Propanediol were used as cryoprotectant. 2. When sucrose was added in freezing solution, the survival was 69.0%. That was higher than the survival of embryos frozen without sucrose in freezing solution. The difference was not significant. 3. Addition and dilution of cryoprotectant by 4 stepwise raised the survival than by direct, but that was not significant. 4. When embryos were frozen by -0.3, -0.5 and $-1^{\circ}C/min$ before plunged into $LN_2$, the survivals were 67.9, 78.0 and 37.0% respectively. The differnce was significant.

  • PDF

Fundamental Study of Energy Harvesting using Thermoelectric Module on Road Facilities (열전소자를 활용한 도로구조물에서의 에너지 하베스팅 기초 연구)

  • Lee, Jae-Jun;Kim, Dae-Hoon;Lee, Kang-Hwi;Lim, Jae-Kyu;Lee, Seung-Tae
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with $CO_2$ emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator's application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS : A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.

Hydrography and Sub-tidal Current in the Cheju Strait in Spring, 1983 (1983년 춘계 제주해협의 해황과 해류)

  • Chang, Kyung-Il;Kim, Kuh;Lee, Suk-Woo;Shim, Tae-Bo
    • 한국해양학회지
    • /
    • v.30 no.3
    • /
    • pp.203-215
    • /
    • 1995
  • Two hydrographic surveys along with direct current measurements using drogues and moored current meters were conducted in Cheju Strait during April and May, 1983. The data clearly demonstrate that a branch of the Kuroshio characterized by high temperature and high salinity enters the Cheju Strait after turning around the western coast of Cheju-Do. The width of the current turning west of Cheju-Do is about 60 km and reduces to 20∼30 km in the strait, resulting in a high speed(>10 cm/s) at the western entrance and in the middle of the strait, compared with a low speed (>5 cm/s) west of Cheju-Do. The Tsushima Current water also originating from the Kuroshio shows its influence in the eastern part of the Cheju Strait. Thermohaline fronts formed between the warm current waters and the coastal waters suggest the southward extension of the Yellow Sea Coastal Water west of the Cheju Strait. A warming of the warm current waters occurs in May, while a cooling takes place in other areas. The major freshening and cooling of water take place in the middle of the Cheju Strait in May due to the intrusion of cold and low salinity water from the west of the Cheju Strait.

  • PDF