• Title/Summary/Keyword: Direct cooling

Search Result 308, Processing Time 0.031 seconds

Heating and cooling properties in cultivation room and cultural characteristics of oyster mushroom according to type of air exchange (외부공기 유입방식에 따른 느타리버섯 생육실의 온도변화 및 자실체의 생육특성)

  • Jang, Myoung-Jun;Lee, Yun-Hae;Ju, Young-Cheol
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.214-218
    • /
    • 2013
  • This study was carried out to find out suitable input method for air exchange about bottle cultivation of oyster mushroom. There was no difference of average temperature in cultivation room, but T1(direct introduction of outside air) was higher than T2(heat exchanger) and T3(air buffer) in the standard deviation. The ratio of cooling operating was the highest in August and in the descending order, T1 54%, T3 43%, T2 33%. At ratio of energy reduction, T2 and T3 were higher than T1. The operating ratio of heater was highest in January and in the descending order, T1 53%, T3 37%, T2 30%. At ratio of energy reduction(%), T2 and T3 were higher than T1 similar to result of cooling operating. Therefore there were largest in August about Cooling Degree-Hour and in January about Heating Degree-Hour. And fruitbody yields quality was excellent in T2 and T3 than T1. The suitable effective type of air exchange in oyster mushroom cultivation are heat exchange and air buffer system.

Effect of LiBr solution flow rates in commercial absorption chiller (상용 흡수식 냉동기에서 LiBr 수용액 유량변화에 따른 영향)

  • Choi, S.H.;Chung, B.C.;Nam, L.W.;Jurng, J.;Chin, S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.292-297
    • /
    • 2001
  • This paper discusses the effect of varying LiBr solution circuits flow rates for a direct fired double effect commercial absorption chiller in the parallel flow configuration. The effects of solution flow rates have been investigated for generator, condenser, solution heat exchanger, absorber and evaporator. According to the result of this work, it was found that sensible heat rate of generator increases and refrigerant vapor generated in that decreases when inlet solution flow rate of that increases. As solution flow rate of absorber increases, the degree of superheat increases because of decreasing solution heat exchanger efficiency. The flashing vapor at the top of absorber increases in proportion to the degree of superheat whileas decreases cooling capacity inversely.

  • PDF

Development of the RE indirect-heating LPE furnace and the effect of impurity in YIG film on the MSSW properties

  • Fujino, M.;Fujii, T.;Sakabe, Y.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.6
    • /
    • pp.288-291
    • /
    • 2002
  • We developed a new RF indirect-heating LPE furnace. The thermal gradient of our newly developed furnace is less than that of direct heating, and is as gentle as that of the resistance-heating LPE furnace. With this new furnace, the heating and/or cooling is faster than that of the resistance-heating furnace. Impurity-doped YIG film was grown from a $PbO-B_{2}O_{3}$, based flux on a (111) GGG substrate. To study the effect of the impurities on the MSSW threshold power and the saturation response time, we used two microstrip lines to excite and propagate the MSSW at 1.9 GHz. The MSSW threshold power and saturation response time was found to be related to the $\Delta$H.

An Experimental Study on Direct Cooling Performance using Pool Boiling from Micro-Porous Coated Surface (마이크로다공성 코팅된 발열체에서의 풀비등 직접냉각 성능에 관한 실험적 연구)

  • Kim, Tae-Gyun;Lee, Kyu-Jung;Kim, Yong-Chan;Park, Chan-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1353-1358
    • /
    • 2004
  • An experimental study of pool boiling behavior on micro-porous enhanced square heater surfaces immersed in PF5060 is performed. The effects of heater orientation, Subcooling and substrate distance on the pool boiling heat transfer performance for the double heaters were investigated under increasing heat-flux conditions. The boiling performance of micro-porous coated surface was better than that of plain surface. The double heaters with upper substrate of 0.2cm substrate interval have lower boiling performances compared with the results for the double heaters with that of 0.5cm and 1.0cm substrate interval and without the substrate. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping.

  • PDF

Analyses of Thrust Bearing in a Scroll Compressor Considering Oldham Ring (올댐링을 고려한 스크롤 압축기 스러스트 베어링의 해석)

  • Park, Sang-Shin;Lee, Seung-Ryoul
    • Tribology and Lubricants
    • /
    • v.23 no.3
    • /
    • pp.109-116
    • /
    • 2007
  • A scroll compressor is on the increase in the use for the cooling and ambition machinery because of the advantages about high efficiency, low vibration and low noise. The design of thrust bearing for scroll compressor has depended on the experience. The lubrication considering the squeeze flow was applied for high side shell and low side shell of scroll thrust bearing. This work was based on governing fluid lubrication equation at the general coordinate. It shows the behavior for an orbiting scroll with direct numerical analysis using FDM. This study obtained the theoretical design value by finding load capacity and tilting angle of an orbiting scroll for thrust bearing in a scroll compressor. Especially this work performed the analysis about the design parameter. The program was written using Visual C++ to enhance user to change the design parameter easily. In particular the result value and the pressure profile were displayed as windows in every step for user to understand without difficulty.

Hygienic Aspects of Campylobacter Enteritis (Campylobacter장염에 의한 식품위생학적인 고찰)

  • 이용욱;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • Campylobacter jejuni has been recognized as one of the causes of human gastroenteritis. The feces of a variety of reservoir animals contain c. jejuni as commensals in the intestinal tracts, and are fundamental source of contamination. The intestinal organisms contaminate carcasses, equipment tools hands of the processing line workers and air of the processing facility. Once the contamination happens in the slaughterhouses or the meat processing facilities, it is very difficult to keep the carcasses free from the infection of c. jejuni. Various disinfectants are effective in minimizing the number of Campylobacter infections in the processing facilities by washing contaminated carcasses, tools, and hands. Direct contact with infected animals has been incriminated in transmission of infection caused by C. jejuni. Freezing, cooling with dry air and gamma irradiation are an effective way for preserving the meat and eliminating the transmission, but broad and enforced studies are needed for the practical use.

  • PDF

A Study on Thermal Characteristics for Hand Carried Ultrasound System

  • Kim, Jong-Gu;Cho, Young-Jin;Kwack, Kae-Dal
    • Journal of Applied Reliability
    • /
    • v.9 no.2
    • /
    • pp.149-163
    • /
    • 2009
  • This paper intends to suggest a design to reduce the thermal load of a hand-carried ultrasound (HCU) system, with the aim of increasing the product life. To design ways to reduce the heat load, the surface temperatures of key parts of an HCU system were measured as the 4 system cooling fans, which have a direct relation to the system life, were operated normally. When the derating rate of 80% was applied while the fans of the HCU system were operated abnormally, it was observed that the key image processing parts exceeded the surface temperature (TC) with consideration to derating. Since the part surface temperature did not exceed the derated level when the regulated voltage was derated from 12V to 9V, it is expected to lower the operating voltage of the fans to 9V to increase the fan and HCU system lifetime by 1.8 times.

  • PDF

Measurement of Calorific Value Using Flame Calorimeter (전자 소자를 이용한 연소열 측정)

  • Lim, Ki-Won;Jun, Jin-Young;Lee, Byeong-Jun
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.40-47
    • /
    • 2010
  • Calorific value of mixed gas, like liquefied natural gas (LNG), is strongly depends on its compositions which are affected by the mining place and producing time. The variation in calorific value have an direct influence on the combustion characteristics and performances of boiler, burner, vehicle, power plants etc. Thus, developing experimental method to measure exact calorific value is becoming an issue in the related industrial fields. Flame calorimeter is developed to get calorific value at the dynamic equilibrium state using electric substitution method. Refrigerant-11 carries heat from combustor and/or heater to the Peltier elements which pumped it out to the cooling water. It is found out that error in the measured calorific value of methane is 2.86% compared with the theoretical one. Developed design technique and the experimental data will be applied to design the national standard gas calorific value measuring apparatus.

A Fundamental Study of Optimization to Control on Height of Roller Shade in Office Building through Mock-up Experiment (Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.148-153
    • /
    • 2008
  • An inflow of daylight to the room offers comfortable view environment, psychological and physical security to people in the room and there are merits such as a work efficiency and energy saving. But, it has many problems as an excessive direct sunlight, cooling and heating. We can expect to have energy saving effect for illumination with comfortable view environment creation through control on height of roller shade. This study will be a used a fundamental approach to control on height of roller shade to changing daylight.

  • PDF

A RAPID DETERMINATION OF $U^{235}$ CONTENTS OF URANIUM SAMPLES UTILIZING HIGH RESOLUTION Ge(Li) DETECTOR (고분해능 Ge(Li) 검출기를 이용한 Uranium 시료내의 $U^{235}$ /$U^{238}$ 함유량의 신속측정)

  • 정문규;조성원;서두환
    • Nuclear Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.33-38
    • /
    • 1969
  • Determinations of the isotopic contents of U$^{235}$ and U$^{238}$ in ten uranium samples containing 0.72-89.70 at % U$^{235}$ were carried out in two ways utilizing high resolution Ge (Li) gamma-ray spectrometer. One method is based upon the fact that the intensity of 185.5 kev gamma-ray vary linearly with U$^{235}$ content for a given geometry. Another method applied for the direct determination of the U$^{235}$ / U$^{238}$ isotopic ratios is the precision gamma-ray spectrometric analysis of reactor irradiated uranium samples after allowing a fixed cooling time for one hour. The results obtained by both methods well agree with the values calculated from the isotopic contents of highly enriched original uranium samples measured by mass spectrometer. The precision obtained was well below 5% for most of the isotopic ratios investigated.

  • PDF