• Title/Summary/Keyword: Direct charging

Search Result 68, Processing Time 0.022 seconds

Analysis of the battery charging and discharging system for spacecrafts (인공위성용 총방전 시스템의 해석)

  • 김영태;김희진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.6
    • /
    • pp.932-942
    • /
    • 1995
  • A spacecraft power system can be divided into two types : DET system(Direct Energy Transfer system) and PPT system(Peak Power Tracking system). In a DET system employing the regulated bus voltage control method, the battery charger and discharger are widely used for the bus voltage regulation. The battery charger has two different modes of operation. One is the bus voltage regulation mode and the other is the charge current regulation mode. The battery discharger is employed to provide the power when the spacecraft is in the earth's shadow or the sun is eclipsed. The operating mode, charging or discharging, is selected by a power control circuit. In this paper, small-signal dynamic characteristics of battery charging and discharging system are analyzed to facilitate design of control loop for optimum performance. Control loop designs in various operating modes are discussed. Anaylses are verified through experiments.

  • PDF

A Study on the Optimal Generation Conditions of Micro-Droplet in Electrostatic Spray Indirect Charging Method (정전 분무 간접 하전 방식에서 미세액적 최적 발생 조건에 관한 연구)

  • Jihee Lee;Sunghwan Kim;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.79-87
    • /
    • 2024
  • This paper is a study on the optimal microdroplet generation conditions in indirect charging electrostatic spraying. Unlike the direct charging method, which applies power to the nozzle, the indirect charging method applies power to the discharge electrode between the nozzle and the collection electrode. Therefore, an electrically simplified system can be obtained by minimizing the insulation part a stable spray pattern can be obtained with a wide spray angle, and a stable spray pattern can be obtained with a wide spray angle. To conduct the study, an indirect charging type electrostatic spray visualization system was constructed and the static characteristics of the microdroplets were analyzed through image processing of the spray shape of the microdroplets. The total number of microdroplets and the number of microdroplets per power consumption are confirmed according to the changes in the distance between the discharge electrode and the collection electrode, the flow rate, and the applied voltage, which affect the generation of microdroplets, and using this, the optimal generation conditions are derived and the corresponding microdroplet size distribution was analyzed. As a result of the experiment, it was confirmed that the optimal generation condition was at a flow rate of 15 to 20 mL/min and a voltage of -22.5 to -25 kV in terms of the number of microdroplets, and at a flow rate of 15 to 20 mL/min and a voltage of -20 kV in terms of energy consumption efficiency.

An Analysis of E-Commerce by Local Governments in Korea (한국 지방자치단체의 전자상거래 유형 분석)

  • Kim, Se Hun;Min, Daihwan
    • Journal of Information Technology Services
    • /
    • v.14 no.4
    • /
    • pp.31-44
    • /
    • 2015
  • Local governments in Korea are involved in three types of online shopping sites : 'direct operation', 'outsourced operation', and 'sales agency.' They are different in terms of the site operator and the charging mechanism among a local government, the site operator, and local producers. This study analyzes their differences in site traffic, local producers' participation, promotion, and partnership. The results from the investigation of 72 shopping sites are the following. First, shopping sites of the 'direct operation' type and the 'outsourced operation' type show significantly higher participation of local producers. Second, the 'marketing agency' type has significantly higher number of promotional activities than the 'oursourced type' which has significantly higher number than the 'direct operation' type. Third, the number of partnerships in the 'marketing agency' type is the highest. The 'direct operation' type is the second and significantly higher than the 'outsourced type.' On the basis of the analysis results, this paper suggests an incubation ecosystem model as a better way of involvement by local governments in online shopping sites.

Dynamic Equivalent Battery as a Metric to Evaluate the Demand Response Performance of an EV Fleet

  • Yoon, Sung Hyun;Jin, Young Gyu;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2220-2226
    • /
    • 2018
  • Electric vehicles (EVs) are significant resources for demand response (DR). Thus, it is essential for EV aggregators to quantitatively evaluate their capability for DR. In this paper, a concept of dynamic equivalent battery (DEB) is proposed as a metric for evaluating the DR performance using EVs. The DEB is the available virtual battery for DR. The capacity of DEB is determined from stochastic calculation while satisfying the charging requirements of each EV, and it varies also with time. Further, a new indicator based on the DEB and time-varying electricity prices, named as value of DEB (VoDEB), is introduced to quantify the value of DEB coupled with the electricity prices. The effectiveness of the DEB and the VoDEB as metrics for the DR performance of EVs is verified with the simulations, where the difference of charging cost reduction between direct charging and optimized bidding methods is used to express the DR performance. The simulation results show that the proposed metrics accord well with the DR performance of an EV fleet. Thus, an EV aggregator may utilize the proposed concepts of DEB and VoDEB for designing an incentive scheme to EV users, who participate in a DR program.

A Study on the Controlling Method of Hunting Inducing Point during Parallel Running of alternator Equipped with converter (컨버터가 내장된 교류발전기 병렬운전중의 헌팅 억제에 관한 연구)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.346-351
    • /
    • 1999
  • This paper is a research for removing the hunting which came about during the parallel running of the alternators which four-pole six-phase have the converter with twelve diodes to rectify all the waves. Druing the parallel running the hunting came about under the period of 0.2-0.3{sec} not when it's load was the resistance but the capacity at the rpm band 1575[rpm] 1690[rpm] This hunting in our judgement was not come about from the general hunting causes which have been already known to but the special example. And so we checked that the hunting came about or not as per the changes of the rpm exciting current load current and converter and converter output voltage and the following facts were revealed. -The hunting occured during the constant voltage charging where r. p. m band is from 1575[rpm] to 1690[rpm] - The hunting did not came about during the constant power charging in which there was the large difference between the converter output voltage and the battery voltage. -The hunting did not came about in the low rpm band. We could see from the above facts that the existence of the hunting inducing point at the con-stant voltage charging band was the direct cause of the hunting. After trying every possible means to remove the hunting inducing point we could know that the modification of the synchronous generator is suitable for he purpos in view of the small engine room.

  • PDF

Development of Lightweight DMFC System for Charging Secondary Battery in Military Operational Environment (군 운용환경에서 이차전지 충전을 위한 경량화 DMFC 시스템 개발)

  • LEE, SUWON;GWAK, GEONHUI;RO, JUNGHO;CHO, YOUNGRAE;KIM, DOYOUN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.481-491
    • /
    • 2017
  • In this study, we developed 300 W lightweight DMFC system for charging secondary battery in small unit military operation. In order to reduce the volumetric shape and weight of the system considering the environment of the individual soldier's, the arranging of system components has been optimized. A metal bipolar plates made of STS-470FC have been implemented to the DMFC stack to meet the weight demand of the system. As a result of the performance test of the stack, the target value was satisfied by outputting 561 W exceeding 24% of the stack output 450 W required to output 300 W required for the entire system. Moreover, 2,655 hours exceeding 1,000 hours also has been satisfied. To ensure good robustness of the metallic bipolar plate based DMFC stack, finite element method based simulations are conducted using a commercial ANSYS Fluent software.

Battery charging device using DMFC for an electric bicycle (DMFC를 사용한 전기자전거 배터리 충전장치)

  • Kim, Young-Ho;Ji, Young-Hyok;Kim, Jae-Hyung;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.255-258
    • /
    • 2008
  • In this paper, the battery charging device using DMFC(Direct Methanol Fuel Cell) for electric bicycle is proposed. In the proposed system, phase-shift full-bridge converter is used as a battery charger by boosting the 12V DMFC output voltage up to 36V. By using the phase-shift technique, the ringing of the transformer is reduced and the efficiency of the converter can be improved. The operation modes of proposed phase-shift full-bridge converter is analyzed and verified by the simulation and the experimental results.

  • PDF

A study on reducing the harmonics in inverter system for fluorescent lamp (형광등용 인버터 시스템의 고조파 저감에 관한 연구)

  • Park, Chan-Kun;Kim, Jong-Yun;Jeon, Nae-Suck;Park, Jeung-Hwan;Lee, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1199-1201
    • /
    • 2000
  • This paper proposes a harmonics reducing circuit for fluorescent lamp inverters using hybrid type smoothing circuit with pumping and smoothing capacitors. A waveform of full-wave rectification used as a direct current power supply at fluorescent lamp inverters contains a lot of harmonic wave from inrush current which is generated near the maximum of input voltage with purse shape when voltage smoothing capacitor is charged. Therefore, in order to suppress inrush current which will result in harmonic wave. this paper proposes a method to control abrupt charging current by use of charging voltage at pumping capacitor. The suppression of harmonics generation at lamp current is confirmed through simulations.

  • PDF

The Reduction of Unburned Hydrocarbons on the Direct-Injection Stratified-Charge Combustion Method by Hydrogen Addition (직접분사 성층연소방식에서 수소 첨가에 의한 미연 탄화수소의 저감)

  • 홍명석;김경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.46-57
    • /
    • 1996
  • The direct injection stratified charge(DISC) engine enhances the fuel tolerance and the antiknock tendency. This enhanc3d antiknock tendency allows use of a higher compression ratio which results in higher thermal efficiency. But its actual utilization is prevented by high emission combustion time and wall quenching will be the main causes of increasing unburned hydrocarbons in DISC system. In order to solve this problem, small aount of hydrogen was added to the charging air or injected fuel. The effects of hydrogen addition were examined experimentally by radial fuel injection using a pancake-type constant volume bomb. In case of the hydrogen addition to the charge of air, the combustion the amount of hydrogen. In case of the hydrogen addition to the fuel, the combustion pressure was significantly increased.

  • PDF

A Study on the Piezo Injector Control Algorithm for CRDI Diesel Engines (커먼레일 디젤 엔진용 피에조 인젝터 제어에 관한 연구)

  • Oh, Byoung-Gul;Oh, Seung-Suk;Park, Yeong-Seop;Lee, Kang-Yoon;SunWoo, Myoung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.54-62
    • /
    • 2009
  • The purpose of this study is to develop a piezo injector driver for common-rail direct injection diesel engines. In this research, we analyzed the electrical and mechanical characteristics of the piezo actuator through experiments. Current flow and charging voltage of the piezo injector are controlled by the PWM signal of variable duty ratio in order to realize both fast response and low peak current. The optimal switching duty ratio was designed by modeling and analyzing of the piezo driver circuit. In order to avoid resonance and unacceptably long settling time, appropriate frequency range of the PWM signal was derived based on the driver circuit model. The developed injector driver was validated by experiments under various fuel rail pressure, injection duration, and charging voltage.